Installationsplan PW 6055/PW 6065 AV/LP EL
Stand: 02.05.2005 Seite 10
3. Standard voltage (as supplied) V 3 AC 440
Frequency Hz 60
Rated load kW 5.05
Fuse rating A 3 × 16
OS 440
Connection cable, min. cross-section mm² 4 × 1.5
Length of supply lead (supplied) mm 2000
Plug and socket connection in accordance with IEC 60309
recommended to facilitate electrical safety tests.
Install mains isolator according to IEC 60947 on hard-wired
connection.
Wall socket or mains isolator must be accessible after
installation.
The use of an earth leakage circuit breaker (ELCB) is strongly
recommended. If an ELCB is fitted, it must be a Type B RCD
able to cope with rectified three-phase supplies.
If necessary, equipotential bonding with good galvanic contact
must be provided in accordance with all appropriate national
and local regulations.
Min. flow pressure kPa 100
Max. pressure kPa 1000
Cold water
Max. throughput (if hot water supply is not available) l/min 10 (11)
On-site connection thread according to DIN 44 991 Inch ¾" external thread
Length of connection hose (parts supplied: 1 connection
hose)
mm 1500
Water requirements (average for 60°C programme)
Standard connection [with hot water connection]
PW 6055 (PW 6065) l/h approx. 36
Additional requirements if hot water supply is not available.
Max. temperature °C 70
Min. flow pressure kPa 100
Hot water
Max. pressure kPa 1000
Max. throughput l/min 11
On-site connection thread according to DIN 44 991 Inch ¾" external thread
Length of connection hose (parts supplied: 1 connection
hose)
mm 1500
Water requirements (average for 60°C programme)
Standard connection [with hot water connection]
PW 6055 (PW 6065) l/h approx. 13
In absence of hot water, use blind stopper supplied and
reprogramme controls to cold water intake.
Min. flow pressure kPa 100
Max. pressure kPa 1000
Max. throughput (if hot water supply is not available) l/min 11
Alternative water
supply
(Optional) On-site connection thread according to DIN 44 991 Inch ¾" external thread
Length of connection hose (parts supplied: 1 connection
hose)
mm 1500
Water requirements (average for 60°C programme)
Standard connection [with hot water connection]
PW 6055 (PW 6065) l/h approx. 14
When using an alternative water supply, the following
volumes can be deducted from hot or cold water supplies:
Deduction from cold water requirements PW 6055 l/h approx. 4
Deduction from hot water requirements PW 6055 l/h approx. 10
Max. temperature °C 70
Machine drain connection (dext × s × l) [DN 70] mm 75 × 1.9 × 40
On-site drain connection (dint × s × l) [DN 70 sleeve] mm 75 × 1.9 × 50
Drainage via
dump valve
Max. transient throughput l/min 50
Vented drainage required. If ventilation is insufficient, fit Miele
kit, Mat. no. 05238090.
Drain manifolds serving several machines must be of
sufficient cross-section.