SDA-1111
FUNCTIONAL BLOCK DIAGRAM
DESCRIPTION
The SDA-1111 is a reclocked serial digital video
distribution amplifier supporting a wide variety of
compressed and uncompressed serial digital
video signals. The SDA-1111 provides 9 reclocked
outputs with automatic equalization for up to 350
meters of cable (Belden 1694A). The amplifier also
offers signal presence detection and remote
reporting. The SDA-1111 includes reclocking,
providing an additional level of signal integrity in
longcable length applications The SDA-1111
supports DVB-ASI 270 Mbps compressed bit
streams as well as serial digital video at bit rates of
143, 177, 270, 360 and 540 Mbps. The SDA-1111 is
designed to be used in a
DENSITÉ
frame. A single
(for 4 outputs) or double (for 9 outputs) rear
connector panel is required.
FEATURES
•
(1) 75Ω
isolated Digital video input
•
(9) 75Ω
Digital video outputs
•
Auto-detects 525 or 625-line format
•
Compatible with SMPTE-259M (143-360
Mbps) and SMPTE-344M (540 Mbps) digital
video signals
•
Compatible with DVB-ASI (270 Mbps)
•
Reclocking of outputs
•
Signal presence detection and remote
reporting
•
Automatic cable equalization.
Outputs
Input
Remote
1
2
3
6
7
8
9
Attention
Status
Auto
EQ
4
5
Digital Video
Microcontroller
Re-clocker
SPECIFICATIONS
SPECIFICATIONSSPECIFICATIONS
SPECIFICATIONS
INPUT
Signal:
SMPTE-259M (143, 177, 270, 360
Mbps)
SMPTE-344M (540 Mbps)
DVB-ASI (270Mbps)
DVB-SSI/SMPTE-310M (Any rate)
Cable length:
350 m (1148') @ 270Mbps for Belden
1694A
Return loss:
> 15 dB up to 540Mbps
OUTPUTS (4 or 9)
Signal:
SMPTE-259M (143, 177, 270, 360,
540 Mbps)
SMPTE-344M (540 Mbps)
DVB-SSI/SMPTE-310M (Any rate)
DVB-ASI (270Mbps) outputs 1 to 5
only
Return loss:
> 15 dB for up to 540Mbps
Jitter (wideband):
< 0.2 UI p-p
PROCESSING PERFORMANCE
Signal path:
10 bits
Processing delay:
10.5 ns
Power:
1.5 W (single), 2 W (double)
SDA-1111 Reclocked Digital Video Distribution Amplifier
Guide to Installation and Operation
Page
2
of
4
SDA-1111
SDA-1111SDA-1111
SDA-1111
UNPACKING
Make sure the following items have been shipped
with your SDA-1111. If any of the following items are
missing, contact your distributor or Miranda
Technologies Inc.
* SDA-1111 Reclocked Digital Video DA
* SDA-1111 rear panel (single or double)
INSTALLATION
The SDA-1111 must be mounted in a DENSITÉ
frame. The installation includes both the SDA-1111
module, and the rear panel module. It is not
necessary to switch off the power from these frames
when installing or removing the SDA-1111.
Detailed instructions for installing cards and their
associated rear panels in the Densité frame are given
in the Densité Frame manual. Specific points to note
for the SDA-1111 are the following.
Rear panel installation
The SDA-1111 has nine outputs, and making these
available on BNC connectors at the rear of the frame
requires a double-width rear panel. Should the
intended use require a smaller number of outputs, a
single-width rear panel with four BNC output
connectors is also available.
In the case where a double rear panel has been
installed, the module must be installed in the right-
most of the two slots covered by the panel in order to
function. Should it be installed in the wrong slot, the
front panel LED will flash red (see OPERATION for a
discussion of the LED functionality). Move the card to
the other slot for correct operation. No damage will
result to the card should this occur.
OPERATION
Overview
Distribution amplifiers require a minimal operator
interface. The SDA-1111 is equipped with an on-
board LED status indicator, mounted on the front
edge of the card so as to be visible from the front of
the card frame, even when the frame door is closed.
The functionality of this status monitor is described
below.
The DENSITÉ frame incorporates a central controller
card, located in the center of the frame, which is
equipped with an LCD display. The card handles
error reporting and remote control for all cards
installed in the frame. The display shows the error
SDA-1101 - SD DIGITAL VIDEO
Select
Status
Status LED
SELECT button
SDA-1111
Double Single
SDA-1111 Rear Connector Panels
SDA-1111 Reclocked Digital Video Distribution Amplifier
Guide to Installation and Operation
SDA-1111
SDA-1111SDA-1111
SDA-1111
Page
3
of
4
status of any card in the frame whose SELECT
button has been pushed.
The SDA-1111 is also equipped with the remote
reporting and control capabilities of the DENSITÉ
series. Fault reporting is carried out on a frame-wide
basis. There is no individual rear-panel access to the
fault and status reporting port of the SDA-1111.
Interfacing to the outside world is handled by the
frame’s contoller card. The fault reporting protocol is
standardized across the DENSITÉ series of modules.
The communications protocol and functionality are
described elsewhere.
Status Monitor LED
The status monitor LED is located on the front card-
edge of the SDA-1111 module, and is visible through
the front access door of the DENSITÉ frame.
This is a multi-color LED, which indicates module
status by color, and by flashing/steady illumination.
The SDA-1111 uses three of the available modes.
They are summarized in the following table. The
table also indicates that a serial report will be filed for
the indicated error condition, through the remote
reporting protocol of the DENSITÉ frame if it is
operative.
Status Indicator
REPORT COLOR (F=flashing)
SERIAL GPI G Y R FR
No errors 
No Input
Signal 
No rear
panel 
No lock
on input
signal

: Factory default.
NOTE: A “Flashing Yellow” Status LED indicates that
the SELECT button on the front panel has been
pushed, and the card is being accessed via the
communications protocol. The LED color
assignments for the various error conditions can be
reconfigured by the user.
User Interface
Push the SELECT button on the front edge of the
SDA-1111 to see a report of the current error status
on the DENSITÉ frame’s controller card display. The
SDA-1111 has four possible status messages, as
indicated in the following figure:
STATUS
ERROR NO REAR
OK
ERROR NO SIGNAL
ERROR NO LOCK
Pushing the SELECT button will cause the on-card
STATUS LED to flash yellow, and the card identifi-
cation and the current error message will be shown
on the controller card’s display. The STATUS LED
will revert to it’s normal state upon a second push of
the button, or after a short delay otherwise.
Example :
SELECT button pushed when the status LED is
green:
SELECT button pushed when there is no input
signal connected to the rear panel and the LED
is steady red:
S D A - 1 1 1 1
O KS T A T U S
S D A - 1 1 1 1
A LN O S I G N
SDA-1111 Reclocked Digital Video Distribution Amplifier
Guide to Installation and Operation
Page
4
of
4
SDA-1111
SDA-1111SDA-1111
SDA-1111
WARRANTIES
Miranda’s Warranty and Warranty Policy are explained in full detail in the Warranty Information Sheet.
COMPLIANCE
Radio Frequency Interference and Immunity
This unit generates, uses, and can radiate radio frequency energy. If the unit is not properly installed and used in accordance with this
guide, it may cause interference with radio communications. Operation with non-certified peripheral devices is likely to result in interference
with radio and television reception. This equipment has been tested and complies with the limits in accordance with the specifications in:
- FCC Part 15, Subpart B
- CE EN50081-1:1992
- CE EN50082-1:1992.
CONTACT MIRANDA
Head Office Miranda Europe Miranda Asia
Miranda Technologies Inc. 222, 226 Rue De Rosny Mita Nexux Bldg. 2F
3499 Douglas B. Floreani 93100 Montreuil 1-3-33 Mita, Minato-Ku
St. Laurent (Montreal), Que.H4S 1Y6 France Tokyo, Japan 108-0073
Canada
Tel (514) 333 – 1772 +33 1 55 86 87 88 81 3 5730 2988
Fax (514) 333 – 6914 +33 1 55 86 00 29 81 3 5730 2973
Toll free: 1-800-224-9828

Other manuals for DENSITE series

12

This manual suits for next models

1

Other Miranda Amplifier manuals

Miranda ADA-702i Instruction Manual

Miranda

Miranda ADA-702i Instruction Manual

Miranda Densite HDA-1861 Instruction Manual

Miranda

Miranda Densite HDA-1861 Instruction Manual

Miranda SDA-172p User manual

Miranda

Miranda SDA-172p User manual

Miranda VDA-1001 Specification sheet

Miranda

Miranda VDA-1001 Specification sheet

Miranda Densite series DDA-1113 Instruction Manual

Miranda

Miranda Densite series DDA-1113 Instruction Manual

Miranda ADA-1023 Instruction Manual

Miranda

Miranda ADA-1023 Instruction Manual

Miranda DENSITE HDA-1851 Instruction Manual

Miranda

Miranda DENSITE HDA-1851 Instruction Manual

Miranda DENSITE series Instruction Manual

Miranda

Miranda DENSITE series Instruction Manual

Miranda HDA-1811 Instruction Manual

Miranda

Miranda HDA-1811 Instruction Manual

Miranda DENSITE series Instruction Manual

Miranda

Miranda DENSITE series Instruction Manual

Miranda HDA-1801 Instruction Manual

Miranda

Miranda HDA-1801 Instruction Manual

Miranda HDA-1832 Instruction Manual

Miranda

Miranda HDA-1832 Instruction Manual

Miranda DENSITE series Instruction Manual

Miranda

Miranda DENSITE series Instruction Manual

Miranda imaging Series Instruction Manual

Miranda

Miranda imaging Series Instruction Manual

Miranda SDA-122 Instruction Manual

Miranda

Miranda SDA-122 Instruction Manual

Miranda DDA-1112 Instruction Manual

Miranda

Miranda DDA-1112 Instruction Manual

Miranda DENSITE series Instruction Manual

Miranda

Miranda DENSITE series Instruction Manual

Miranda VEA-1002 Instruction Manual

Miranda

Miranda VEA-1002 Instruction Manual

Popular Amplifier manuals by other brands

Conrad-johnson design Evolution 20 owner's manual

Conrad-johnson design

Conrad-johnson design Evolution 20 owner's manual

Gold Note PA-1175 MKII user manual

Gold Note

Gold Note PA-1175 MKII user manual

Trek II SSP-1C user manual

Trek II

Trek II SSP-1C user manual

Unika MT-600Q User instructions

Unika

Unika MT-600Q User instructions

INVADERS Amplification 720 Britt owner's manual

INVADERS Amplification

INVADERS Amplification 720 Britt owner's manual

AmbiSonic Systems L-240 owner's manual

AmbiSonic Systems

AmbiSonic Systems L-240 owner's manual

Trigon Elektronik Advance operating instructions

Trigon Elektronik

Trigon Elektronik Advance operating instructions

Ahuja UBA-500DP Operation manual

Ahuja

Ahuja UBA-500DP Operation manual

Genelec RAM4 Dimensions

Genelec

Genelec RAM4 Dimensions

Hafler SE120 Service manual

Hafler

Hafler SE120 Service manual

JL Audio XDM600/6 owner's manual

JL Audio

JL Audio XDM600/6 owner's manual

Fender Champion 20 user manual

Fender

Fender Champion 20 user manual

Mapletree Line 2B SE user manual

Mapletree

Mapletree Line 2B SE user manual

Pyle Dryver PLAD3300D owner's manual

Pyle

Pyle Dryver PLAD3300D owner's manual

Yamaha MX-A5000 owner's manual

Yamaha

Yamaha MX-A5000 owner's manual

Ericsson 19D902797G5 Maintenance manual

Ericsson

Ericsson 19D902797G5 Maintenance manual

APART Champ-One owner's manual

APART

APART Champ-One owner's manual

Renkforce 1377963 operating instructions

Renkforce

Renkforce 1377963 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.