Miscea LIGHT User manual

LANG
LIGHT
MEMO
LIQUID 2
LIQUID 1
TEMP
DELAY
BUCKET
DURATION
BEEP
DEFAULT
SPOOL
-
+
SAVE
Instruction manual
miscea Remote Control
EN ...9 - 26
DE ...27 - 44
NL ...45 - 62

2
A
1
2
1x
+
CR 2032
3V
+
LANG
LIGHT
MEMO
LIQUID 2
LIQUID 1
TEMP
DELAY
BUCKET
DURATION
BEEP
DEFAULT
SPOOL
-
+
SAVE

V 20.01
3
A - B
B01-B04
1x
2
CR 2032
3V
+
1
OPENER
CR 2032
O
p
e
n
C
l
o
s
e
OPENER
CR 2032
3V
+
4
OPENER
CR 2032
O
p
e
n
C
l
o
s
e
OPENER
CR 2032
3V
+
3
CR 2032
3V
+
1x

4
C
Overview | Übersicht | Overzicht
Position | Position | Positie 1 2 3 4 5 6 7 8 9
Bar position
Balkenposition
Balkenpositie
Min Max
Soap
ca. dosage in ml
Seife
ca. Menge in ml
Zeep
ca. dosering in ml
12345678 9
CLASSIC Ä
LIGHT Ä
KITCHEN Ä
Disinfect
ca. dosage in ml
Desinfektion
ca. Menge in ml
Desinfectant
ca. dosering in ml
2345678912.0
CLASSIC Ä
KITCHEN Ä
Initial water temperature
Anfangstemperatur Wasser
Aanvangstemperatuur water
12345678 9
CLASSIC Ä
KITCHEN Ä
Water shut o delay
in seconds
Nachlaufzeit Wasser
in Sekunden
Nalooptijd water
in seconden
0.5 1.0 1.5 2.0 3.0 5.0 10 30 60
CLASSIC Ä
LIGHT Ä
KITCHEN Ä
Water temperature memory
in seconds
Speicherzeit Wassertemperatur
in Sekunden
Tijdsduur opgeslagen
watertemperatuur
0 5 10 15 30 45 60 90 120
CLASSIC Ä
KITCHEN Ä
Duration of bucket mode
in minutes
Dauerlauf Wasser
pro Minute
Tijdsduur emmermodus
in minuten
0.5 1 1.5 2 3 4 5 10 20
CLASSIC Ä
Light settings
Lichteekte
Lichtinstellingen
OFF PULSE ON
CLASSIC Ä
LIGHT Ä
KITCHEN Ä
EN: Default settings are highlighted in green. DE: Die Standardeinstellungen sind grün. NL: De standaardinstellingen zijn groen gemarkeerd.

V 20.01
5
C - D
D
Overview | Übersicht | Overzicht
Position | Position | Positie 1 2 3 4 5 6 7 8 9
Bar position
Balkenposition
Balkenpositie
Min Max
Time between Spool Cycle
in hours
Zeitabstand Spülzyklus
in Stunden
Tijdsduur tussen spoelcycli
in uren
04* 24 8* 48 12* 72 24* 96 48* 120 72* 144 96* 168 120* 252
CLASSIC Ä
LIGHT Ä
KITCHEN Ä
EN: From faucet software version 1.59 and higher, times marked with * apply.
DE: Mit * markierte Zeiten gelten nur ab Auslauf-Software-Version 1.59 und höher.
NL: Tijden gemarkeerd met * zijn de tijden voor kranen met software versie 1.59 of hoger.
Duration of Spool Cycle
in minutes
Dauer Spülzyklus
pro Minute
Tijdsduur van spoelcyclus
in minuten
0 2 4 6 8 10 15 20 30
CLASSIC Ä
LIGHT Ä
KITCHEN Ä
Beep tone
Signalton
Pieptoon
OFF VOL 1 VOL 2 VOL 3 VOL 4 VOL 5 VOL 6 VOL 7 VOL 8
CLASSIC Ä
LIGHT Ä
KITCHEN Ä
EN: Certain functions are available only from specic faucet software versions and higher. This is indicated next to each model.
DE: Bestimmte Funktionen gelten nur ab bestimmten Auslauf-Software-Versionen und höher. Dies ist neben jedem Modell angegeben.
NL: Bepaalde functiies zijn geldig voor kranen vanaf een speciek software versie of hoger. Dit staat bij elk model aangegeven.
Position | Position | Positie 1 2 3 4 5 6 7 8 9
Manual Flush
Manuelles Spülen
Manuele waterspoeling
OFF ON
CLASSIC (v.1.61+) Ä
LIGHT (v.1.23+) Ä
KITCHEN (v.1.61+) Ä
Automatic Stagnation Flush
Power on
Automatische Stagnations-
spülung beim Einschalten
Automatische spoeling na het
opstarten van het systeem
OFF ON
CLASSIC (v.1.61+) Ä
LIGHT (v.1.23+) Ä
KITCHEN (v.1.61+) Ä
EN: Default settings are highlighted in green. DE: Die Standardeinstellungen sind grün. NL: De standaardinstellingen zijn groen gemarkeerd.

6
E
Overview | Übersicht | Overzicht
Position | Position | Positie 1 2 3 4 5 6 7 8 9
Bar position
Balkenposition
Balkenpositie
Min Max
IR Sensor Sensitivity
ca. in cm
Empndlichkeit der Sensoren
ca. in cm
IR Sensor Gevoeligheid
ca. in cm
2 2.5 4 4.5 8 9 10 11 12
CLASSIC (v.0.38+) Ä
LIGHT (v.0.14+) Ä
KITCHEN (v.0.38+) Ä
Cleaning Mode
Reinigungsmodus
Reinigingsmodus
OFF ON
CLASSIC (v.1.56+) Ä
KITCHEN (v.1.58+) Ä
End Point Filter Mode
Endstellenlter Modus
Eindpunt Filter Modus
OFF ON
CLASSIC (v.1.61+) Ä
LIGHT (v.1.23+) Ä
Hand Disinfection Timer
in seconds
Timer für Händedesinfektion
in Sekunden
Timer voor handdesinfectie
in seconden
0 20 30 40 50 60 90 105 120
CLASSIC (v.1.61+) Ä
KITCHEN (v.1.61+) Ä
Hand Washing Timer
in seconds
Timer für Handwäsche
in Sekunden
Timer voor handenwassen
in seconden
0 20 25 30 35 40 45 50 55
CLASSIC (v.1.61+) Ä
LIGHT (v.1.23+) Ä
KITCHEN (v.1.61+) Ä
Settings for Instantaneous
water heater
Einstellungen für Durchlaufer-
hitzer
Instellingen voor heetwater-
geisers
DEFAULT 1 2
CLASSIC (v.1.56+) Ä
KITCHEN (v.0.41+) Ä
EN: Setting 1 is best suited for waterbox software version 0.23. Setting 2 is best suited for waterbox software version 0.24.
DE: Einstellung 1 ist kompatibel zur Wasserbox Software-Version 0.23. Einstellung 2 ist kompatibel zur Wasserbox Software-Version 0.24.
NL: Instelling 1 is compatibel met waterbox software versie 0.23. SInstelling 2 is compatibel met waterbox software versie 0.24.
EN: Default settings are highlighted in green. DE: Die Standardeinstellungen sind grün. NL: De standaardinstellingen zijn groen gemarkeerd.
EN: Certain functions are available only from specic faucet software versions and higher. This is indicated next to each model.
DE: Bestimmte Funktionen gelten nur ab bestimmten Auslauf-Software-Versionen und höher. Dies ist neben jedem Modell angegeben.
NL: Bepaalde functiies zijn geldig voor kranen vanaf een speciek software versie of hoger. Dit staat bij elk model aangegeven.

V 20.01
7
E - F
Public Mode | Modus für den öentlichen Bereich | Publieke Gebruiksmodus
EN: Default settings are highlighted in green. DE: Die Standardeinstellungen sind grün. NL: De standaardinstellingen zijn groen gemarkeerd.
F
Position | Position | Positie 1 2 3 4 5 6 7 8 9
Bar position
Balkenposition
Balkenpositie
Min Max
Public Mode
Modus für den öentlichen
Bereich
Publieke Gebruiksmodus
OFF ON
CLASSIC Pure S (v.1.63+) Ä
LIGHT (v.1.22+) Ä
First water cycle delay
in seconds
Verzögerungszeit des 1. Was-
serzyklus
in Sekunden
Wachttijd de 1. waterlooptijd
in seconden
0 0.5 1 1.5 2 2.5 3 3.5 4
CLASSIC Pure S (v.1.63+) Ä
LIGHT (v.1.22+) Ä
Duration of rst water cycle
in seconds
Dauer des 1. Wasserzyklus
in Sekunden
Tijdsduur de 1. waterlooptijd
in seconden
0 0.5 1.5 2.5 3.5 4.5 5.5 6.5 7.5
CLASSIC Pure S (v.1.63+) Ä
LIGHT (v.1.22+) Ä
Duration of second water cycle
in seconds
Dauer des 2. Wasserzyklus
in Sekunden
Tijdsduur de 2. waterlooptijd
in seconden
0 2 4 6 8 10 12 14 16
CLASSIC Pure S (v.1.63+) Ä
LIGHT (v.1.22+) Ä
EN: Certain functions are available only from specic faucet software versions and higher. This is indicated next to each model.
DE: Bestimmte Funktionen gelten nur ab bestimmten Auslauf-Software-Versionen und höher. Dies ist neben jedem Modell angegeben.
NL: Bepaalde functiies zijn geldig voor kranen vanaf een speciek software versie of hoger. Dit staat bij elk model aangegeven.

8
LANG
LIGHT
MEMO
LIQUID 2
LIQUID 1
TEMP
DELAY
BUCKET
DURATION
BEEP
DEFAULT
SPOOL
-
+
SAVE
3.2
3.2 3.4 / 4.1 / 4.2
3.9 3.10
3.5 3.6 / 4.5
3.11 3.12
3.7 / 4.7 3.8
3.13

LANG
LIGHT
MEMO
LIQUID 2
LIQUID 1
TEMP
DELAY
BUCKET
DURATION
BEEP
DEFAULT
SPOOL
-
+
SAVE
NL
EN DE
Instruction manual
miscea Remote Control

10
© 2020 miscea GmbH
No part of this publication may be reproduced, transmitted, transcribed, stored in any retrieval system or
translated into any human or computer language by any means or in any form, without the prior written
permission of miscea. Contravention of the owner’s copyright may also reduce the ability of miscea to
provide eective support for its equipment.
All technical information, data and instructions contained in this manual for operations that can and are
to be performed, are up to date at the time of editing.
This manual contains our current knowledge and experience to the best of our understanding.
We reserve the right to make technical modications arising from further development of the miscea
product presented in these operating instructions. For this reason, no claims may be derived from
technical data, descriptions and illustrations.
miscea reserves the right to make changes without notice to both this manual and to its products
described within this manual. Nothing in this manual represents any contractual or other commitment on
the part of miscea and should not be taken as such. All possible care has been taken in the preparation
of this publication. Contact miscea for suggestions of improvement. This manual is originally written in
English. A copy is available on request.
Version: V20.01
NL
EN DE

V 20.01
11
English
1. General 12
1.1 About this manual 12
2. Description 12
2.1 Components 12
3. Use 12
3.1 Use of remote control 12
3.2 Put system in standby mode 12
3.3 Change dosage soap / liquid 1 13
3.4 Change dosage disinfectant / liquid 2 13
3.5 Change initial water temperature 14
3.6 Change water shut o delay time 14
3.7 Change water temperature memory time 15
3.8 Change duration of bucket mode 15
3.9 Change duration between automatic spool cycle 16
3.10 Change duration of automatic spool cycle 16
3.11 Change system light settings 17
3.12 Change the sound level of the beep tone 17
3.13 Restore factory settings 18
3.14 Replacing the battery 18
4. Public Mode 18
4.1 Enable / Disable the Public Mode 19
4.2 Change the rst water cycle delay time 19
4.3 Change the duration of water ow in rst water cycle 19
4.4 Change duration system is in second water cycle 20
5. Additional Settings 21
5.1 Manual Flush 21
5.2 Automatic Stagnation Flush at Power On 21
5.3 IR Sensor Sensitivity 22
5.4 Hand Disinfection Timer 22
5.5 Hand Washing Timer 23
5.6 Cleaning Mode 23
5.7 miscea System Settings for Instantaneous Water Heaters 24
5.8 End Point Filter Mode 24
6. Warranty and Information 26
6.1 Warranty 26
6.2 Warranty conditions 26
6.3 Contact information 26
6.4 Updates of the manual 26
Table of contents

12
1.1 About this manual
This manual includes technical specications, instructions and explanations that help to use this product
safely. Read and understand these instructions before you operate the product.
The illustrations, drawings and graphics in this manual may be dierent from the actual components.
Contact your local supplier for questions that are not answered in this manual.
Keep this manual for future reference.
1. General
2. Description
3. Use
With the remote control, you can change the default settings on miscea sensor faucets. The settings
that can be changed include, but are not limited to: starting water temperature, the amount of liquids
dispensed, automatic spool cycle, light pulse, beep tone, bucket mode, water shut o delay time and
restoring to factory default settings.
For further information, please visit our website for the miscea representative in your country.
2.1 Components
Refer to g. A for the identication of the components.
1. Remote control
2. Battery
3.1 Use of the remote control
Please refer to the instruction manual of your miscea system for further instructions on how to
use the remote control specic to your model.
Unless indicated otherwise, there are 9 settings available for each function. Each setting is
indicated with a dierent beep tone. For miscea models with a display screen, this will also be
indicated visually on the screen.
Default settings are higlighted in green.
3.2 Put system in standby mode
The «STANDBY» button turns the miscea faucet on and o.
NOTE: In standby mode, the automatic spool cycle function is still operational.

V 20.01
13
English
3.4 Change dosage disinfectant / liquid 2
Change the amount of disinfectant/liquid 2 dispensed.
Press the «LIQUID 2» button. The orange light of the «Disinfectant/Liquid 2» segment
will light up. With the «+» and «-» buttons the amount of liquid 2 can be changed. To
save settings, press the «SAVE» button. All colored LED lights illuminate to indicate the
new setting has been saved. If the «SAVE» button is not pressed within 10 seconds of
the last selection, the previously saved setting will be stored.
LIQUID 2
3. Use
3.3 Change dosage soap / liquid 1
Change the amount of soap/liquid 1 dispensed.
Press the «LIQUID 1» button. The green light of the «Soap/Liquid 1» segment will
light up. With the «+» and «-» buttons the amount of liquid 1 can be changed. To save
settings, press the «SAVE» button. All colored LED lights illuminate to indicate the new
setting has been saved. If the «SAVE» button is not pressed within 10 seconds of the
last selection, the previously saved setting will be stored.
LIQUID 1
Position 1 2 3 4 5 6 7 8 9
Bar position Min Max
Soap / Liquid 1
ca. dosage in ml 12345678 9
CLASSIC Ä
LIGHT Ä
KITCHEN Ä
Position 1 2 3 4 5 6 7 8 9
Bar position Min Max
Disinfect / Liquid 2
ca. dosage in ml 2345678912
CLASSIC Ä
KITCHEN Ä

14
3.5 Change initial water temperature
Compatible systems allow water temperature to be set at the preferred level in the
initial water temperature setting.
Press «TEMP» button. The «+» and «-» sectors on the faucet will light up red and blue
respectively. With the «+» and «-» buttons on the remote control, the initial starting
water temperature can be changed. To save settings, press the «SAVE» button. All
colored LED lights illuminate to indicate the new setting has been saved. If the «SAVE»
button is not pressed within 10 seconds of the last selection, the previously saved
setting will be stored.
3. Use
TEMP
Position 1 2 3 4 5 6 7 8 9
Bar position Min Max
Initial water temperature
CLASSIC Ä
KITCHEN Ä
3.6 Change water shut o delay time
Water shut o delay time refers to the duration of water ow from the point of time
hands are outside the detection range of the water sector. For example, water
continues to ow for (X) seconds after hands are removed from water sector.
Press the «DELAY» button. The water sector will light up. With the «+» and «-» buttons,
the water shut o delay time can be changed. To save settings, press the «SAVE»
button. All colored LED lights illuminate to indicate the new setting has been saved. If
the «SAVE» button is not pressed within 10 seconds of the last selection, the previously
saved setting will be stored.
DELAY
Position 1 2 3 4 5 6 7 8 9
Bar position Min Max
Water shut o delay
in seconds 0.5 1 1.5 2 3 5 10 30 60
CLASSIC Ä
LIGHT Ä
KITCHEN Ä

V 20.01
15
English
3. Use
3.7 Change water temperature memory time
Water temperature memory time refers to the duration for which the most recently
used water temperature is temporarily stored in memory. For example, when the water
temperature is altered and the water sector is activated in quick intervals, the last used
temperature will be temporarily stored in the faucet memory for an (X) amount of time.
Press the «MEMO» button. The water sector will light up. The «+» and «-» sectors on
the faucet will light up red and blue respectively. With the «+» and «-» buttons on the
remote control, the water temperature memory time can be changed. To save settings,
press the «SAVE» button. All colored LED lights illuminate to indicate the new setting
has been saved. If the «SAVE» button is not pressed within 10 seconds of the last
selection, the previously saved setting will be stored.
MEMO
3.8 Change duration of bucket mode
Duration of bucket mode refers to the length of time the system remains in the bucket
mode after activation. This function is not available on all miscea models.
Press the «BUCKET» button. The water sector will light up. With the «+» and «-»
buttons, the duration of time the system remains in bucket mode can be changed. To
save settings, press the «SAVE» button. All colored LED lights illuminate to indicate the
new setting has been saved. If the «SAVE» button is not pressed within 10 seconds of
the last selection, the previously saved setting will be stored.
BUCKET
Position 1 2 3 4 5 6 7 8 9
Bar position Min Max
Water temperature memory
in seconds 0 5 10 15 30 45 60 90 120
CLASSIC Ä
KITCHEN Ä
Position 1 2 3 4 5 6 7 8 9
Bar position Min Max
Duration of bucket mode
in minutes 0.5 1 1.5 2 3 4 5 10 20
CLASSIC Ä

16
3. Use
3.9 Change the duration between automatic spool cycles
The spool function is used to prevent the formation of legionella and other waterborne
pathogenic microorganisms in the water system. The system will automatically spool
itself with water after a certain amount of time the system has not dispensed water
while connected to a power supply. While spooling, the system automatically passes
step by step the entire temperature eld beginning with cold water and ending with hot
water.
NOTE
In order for the automatic spool function to work correctly please ensure the following
conditions are met:
• the miscea system must be always be connected to power
• the duration of the automatic spool cycle is not set to 0 min.
See 3.10 “Change duration of automatic spool cycle”
Press «SPOOL» button. The water sector will light up. With the «+» and «-» buttons on
the remote control, the duration of time between spool cycles can be changed. To save
settings, press the «SAVE» button. All colored LED lights illuminate to indicate the new
setting has been saved. If the «SAVE» button is not pressed within 10 seconds of the
last selection, the previously saved setting will be stored.
3.10 Change duration of automatic spool cycle
During the spool cycle, water will automatically dispense for a certain amount of time
referred to as the DURATION on the remote control. While spooling, the system auto-
matically passes step by step the entire temperature eld beginning with cold water and
ending with hot water.
Press the «DURATION» button. The water sector will light up. With the «+» and «-»
buttons, the duration of continuous water ow in spool mode can be changed. To save
settings, press the «SAVE» button. All colored LED lights illuminate to indicate the new
setting has been saved. If the «SAVE» button is not pressed within 10 seconds of the
last selection, the previously saved setting will be stored.
SPOOL
Position 1 2 3 4 5 6 7 8 9
Bar position Min Max
Time between Spool Cycle
in hours 04* 24 8* 48 12* 72 24* 96 48* 120 72* 144 96* 168 120* 252
Duration of Spool Cycle
in minutes 0 2 4 6 8 10 15 20 30
CLASSIC Ä
LIGHT Ä
KITCHEN Ä
EN: From faucet software version 1.59 and higher, times marked with * apply.
DURATION

V 20.01
17
English
3. Use
3.11 Change the system light settings
The lights in the head of the miscea faucet can be put into the following 3 modes: on,
pulse and o.
Press the «LIGHT» button. Use the «+» and «-» buttons to switch between dierent
light modes. To save settings, press the «SAVE» button. All colored LED lights illumi-
nate to indicate the new setting has been saved. If the «SAVE» button is not pressed
within 10 seconds of the last selection, the previously saved setting will be stored.
LIGHT
Position 1 2 3 4 5 6 7 8 9
Bar position Min Max
Light settings OFF PULSE ON
CLASSIC Ä
LIGHT Ä
KITCHEN Ä
Position 1 2 3 4 5 6 7 8 9
Bar position Min Max
Beep tone OFF VOL 1 VOL 2 VOL 3 VOL 4 VOL 5 VOL 6 VOL 7 VOL 8
CLASSIC Ä
LIGHT Ä
KITCHEN Ä
3.12 Change the sound level of the beep tone
The sound level of the beep tone can be changed.
Press the «BEEP» button. Use the «+» and «-» buttons to switch between the 9
dierent sound level settings. To save settings, press the «SAVE» button. All colored
LED lights illuminate to indicate the new setting has been saved. If the «SAVE» button
is not pressed within 10 seconds of the last selection, the previously saved setting will
be stored.
BEEP

18
3. Use
3.13 Restore factory settings
The «DEFAULT» button can be used to restore the miscea system to factory settings.
To restore factory settings, press «DEFAULT». All colored LED lights will start blinking.
Press «SAVE» to nalize the factory restore.
If the «SAVE» button is not pressed within 10 seconds of the last selection, the previ-
ously saved setting will be stored. Please see Fig. C - F for default settings overview.
3.14 Replacing the battery
To replace the battery when it is out of power, see Fig. B01-B04.
DEFAULT
The public mode is a simplied user mode designed for public settings. In this mode, the user does not
need to actively select the soap sector in order to receive soap.
1. When the user rst places a hand under the water outlet, a small dose of soap is automati-
cally dispensed. There is a short delay before the next step.
2. This is followed by a small amount of water.
3. After this, the water sector will remain selected and illuminated for a set amount of time while
the user scrubs and lathers hands. When the user is ready to rinse, simply place hands
under the water outlet to receive water.
Once the water sector is no longer illuminated, the water sector is no longer selected and the cycle has
ended. When the user now places a hand under the water outlet, the cycle begins again with soap.
Fig. G
4. Public Mode
1. 3.2.
A

V 20.01
19
English
4. Public Mode
4.1 Enable / Disable the Public Mode
miscea LIGHT Model
Press the buttons indicated in the following order:
«LIQUID 2» button,
Enable: «+» button / Disable: «-» button,
«SAVE» button.
miscea CLASSIC Pure S Model
Press the buttons indicated in the following order:
«LIGHT», «LIQUID 2», «LANG» buttons,
Enable: «+» button / Disable: «-» button,
«SAVE» button.
Position 1 2 3 4 5 6 7 8 9
Bar position Min Max
Enable / Disable OFF ON
CLASSIC Pure S (v.1.63+) Ä
LIGHT (v.1.22+) Ä
First water cycle delay time
in seconds 0 0.5 1 1.5 2 2.5 3 3.5 4
CLASSIC Pure S (v.1.63+) Ä
LIGHT (v.1.22+) Ä
These functions are available with faucet software version starting from version number indicated next to each model.
4.2 Change the short water cycle delay time
The short water cycle delay time refers to the waiting state the faucet is in after the soap has been
dispensed, to give the user an opportunity to lather soap on their hands without the water ushing the
soap away immediately. Refer to letter A in Fig. G.
The water sector will light up. With the «+» and «-» buttons, the delay time can be changed. To save
settings, press «SAVE» button. All colored LED lights illuminate to indicate the new setting has been
saved. If the «SAVE» button is not pressed within 10 seconds of the last selection, the previously saved
setting will be stored.
miscea LIGHT Model
With the Public Mode enabled, press «MEMO»
button on the remote control.
miscea CLASSIC Pure S Model
With the Public Mode enabled, press the buttons
indicated in the following order:
MEMO BUCKET LANG
LIGHT
LIQUID 2
LIGHT LANG
SAVE
LIQUID 2
SAVE

20
4. Public Mode
4.3 Change the duration of water ow in short water cycle
The short water cycle is intended to make obvious to the user that the water sector is now activated and
allows the user to wet their hands. During the short water cycle, the water sector will light up, and a small
amount of water will be automatically dispensed for a specied amount of time. This water ow time can
be changed. Refer to nr. 2 in Fig. G.
The water sector will light up. With the «+» and «-» buttons, the water ow time can be changed. To
save settings, press «SAVE» button. If the «SAVE» button is not pressed within 10 seconds of the last
selection, the previously saved setting will be stored.
miscea LIGHT Model
With the Public Mode enabled, press the «TEMP»
button on the remote control.
miscea CLASSIC Pure S Model
With the Public Mode enabled, press the buttons
indicated in the following order:
TEMP DELAY LANG
LIGHT
4.4 Change duration system is in long water cycle
After the water ow in the short water cycle has stopped, the long water cycle begins. The light in the
water sector stays illuminated for the entire duration the long water cycle is active. The system will allow
the user to get water on demand and rinse their hands. Refer to nr. 3 in Fig. G. The duration of time the
system stays in the long water cycle can be changed with the remote control.
The water sector will light up. With the «+» and «-» buttons, the duration of time that the water sector
stays activated after the short water cycle has occurred can be changed. To save settings, press
«SAVE» button. If the «SAVE» button is not pressed within 10 seconds of the last selection, the previ-
ously saved setting will be stored.
miscea LIGHT Model
With the Public Mode enabled, press «BUCKET»
button on the remote control.
miscea CLASSIC Pure S Model
With the Public Mode enabled, press the buttons
indicated in the following order:
BUCKETDURATION LANGLIGHT
Position 1 2 3 4 5 6 7 8 9
Bar position Min Max
Duration of rst water cycle
in seconds 0 0.5 1.5 2.5 3.5 4.5 5.5 6.5 7.5
CLASSIC Pure S (v.1.63+) Ä
LIGHT (v.1.22+) Ä
Duration of second water cycle
in seconds 0 2 4 6 8 10 12 14 16
CLASSIC Pure S (v.1.63+) Ä
LIGHT (v.1.22+) Ä
These functions are available with faucet software version starting from version number indicated next to each model.
Other manuals for LIGHT
2
This manual suits for next models
1
Table of contents
Languages:
Other Miscea Remote Control manuals
Popular Remote Control manuals by other brands

THOMSON
THOMSON ROC1128PHI operating instructions

Daikin
Daikin BRC1E61 Operation manual

Telemotive
Telemotive Tekemotive XLTX instruction manual

Nice
Nice NX FIT MB 534 SH BD Instructions and warnings for installation and use

Remote Control Systems
Remote Control Systems TITAN-TRACKSIDE-3 instruction manual

Baxi
Baxi AVS77 instructions