2
Contents
1. Safety precautions......................................................................................... 2
2. Selecting the installation location................................................................... 2
3. Installation diagram........................................................................................ 3
4. Installing the indoor unit................................................................................. 3
5. Refrigerant piping work.................................................................................. 5
6. Drainage piping work..................................................................................... 6
7. Electrical work................................................................................................ 7
8. Test run........................................................................................................ 13
9. System control ............................................................................................ 15
10. Installing the grille........................................................................................ 15
11. Easy maintenance function.......................................................................... 18
1. Safety precautions
• Besuretoread“Safetyprecautions”beforeinstallingtheairconditioner.
• Besuretoobservethecautionsspeciedhereastheyincludeimportant
itemsrelatedtosafety.
• Theindicationsandmeaningsareasfollows.
Warning:
Couldleadtodeath,seriousinjury,etc.
Caution:
Couldleadtoseriousinjuryinparticularenvironmentswhenoperatedincor-
rectly.
• Afterreadingthismanual,besuretokeepittogetherwiththeinstruction
manualinahandyplaceonthecustomer’ssite.
: Indicates a part which must be grounded.
Warning:
Carefullyreadthelabelsaffixedtothemainunit.
Installtheindoorunitatleast2.5mabovefloororgradelevel.
Forappliancesnotaccessibletothegeneralpublic.
Warning:
• Donotinstallitbyyourself(customer).
Incompleteinstallationcouldcauseinjuryduetore,electricshock,theunit
fallingorleakageofwater.Consultthedealerfromwhomyoupurchasedthe
unitorspecialinstaller.
• Installtheunitsecurelyinaplacewhichcanbeartheweightoftheunit.
Wheninstalledinaninsufcient strong place, the unit could fall causing
injured.
• Usethespeciedwirestoconnecttheindoorandoutdoorunitssecurelyand
attachthewiresrmlytotheterminalboardconnectingsectionssothestress
ofthewiresisnotappliedtothesections.
Incompleteconnectingandxingcouldcausere.
• Donotuseintermediateconnectionofthepowercordortheextensioncord
anddonotconnectmanydevicestooneACoutlet.
Itcouldcauseareoranelectricshockduetodefectivecontact,defective
insulation,exceedingthepermissiblecurrent,etc.
• Checkthattherefrigerantgasdoesnotleakafterinstallationhascompleted.
• Performtheinstallationsecurelyreferringtotheinstallationmanual.
Incompleteinstallationcould cause a personal injury duetore,electric
shock,theunitfallingorleakageofwater.
• Performelectricalworkaccordingtotheinstallationmanualandbesureto
useanexclusivecircuit.
Ifthecapacityofthepowercircuitisinsufcientorthereisincompleteelectri-
calwork,itcouldresultinareoranelectricshock.
• Theusershouldneverattempttorepairtheunitortransferittoanotherloca-
tion.
• Theapplianceshallbeinstalledinaccordancewithnationalwiringregula-
tions.
• Ifthesupplycordisdamaged,itmustbereplacedbythemanufacturer,its
serviceagentorsimilarlyqualiedpersonsinordertoavoidahazard.
• Attachtheelectricalpartcovertotheindoorunitandtheservicepaneltothe
outdoorunitsecurely.
Iftheelectricalpartcoverintheindoorunitand/ortheservicepanelinthe
outdoorunitarenotattachedsecurely,itcouldresultinareoranelectric
shockduetodust,water,etc.
• Besuretousethepartprovidedorspeciedpartsfortheinstallationwork.
Theuseofdefectivepartscouldcauseaninjuryorleakageofwaterduetoa
re,anelectricshock,theunitfalling,etc.
• Ventilatetheroomifrefrigerantleaksduringoperation.
If the refrigerant comes in contact with a ame, poisonous gases will be
released.
• Wheninstallingorrelocating,orservicingtheairconditioner,useonlythe
speciedrefrigerant(R410A)tochargetherefrigerantlines.Donotmixitwith
anyotherrefrigerantanddonotallowairtoremaininthelines.
Ifairismixedwiththerefrigerant,thenitcanbethecauseofabnormalhigh
pressureinthe refrigerantline,and may resultinan explosion andother
hazards.
Theuseofanyrefrigerantotherthanthatspeciedforthesystemwillcause
mechanicalfailure orsystemmalfunctionorunit breakdown.Intheworst
case,thiscouldleadtoaseriousimpedimenttosecuringproductsafety.
Caution:
• Performgrounding.
Donotconnectthegroundwiretoagaspipe,waterpipearresterortelephone
groundwire.Defectivegroundingcouldcauseanelectricshock.
• Donotinstalltheunitinaplacewhereaninammablegasleaks.
Ifgasleaksandaccumulatesintheareasurroundingtheunit,itcouldcause
anexplosion.
• Installagroundleakagebreakerdependingontheinstallationplace(where
itishumid).
If a ground leakage breaker is not installed, it could cause an electric
shock.
• Performthedrainage/piping work securelyaccording to theinstallation
manual.
Ifthereisadefectinthedrainage/pipingwork,watercoulddropfromtheunit
andhouseholdgoodscouldbewetanddamaged.
• Fastenaarenutwithatorquewrenchasspeciedinthismanual.
Whenfastenedtootight,aarenutmaybrokenafteralongperiodandcause
aleakageofrefrigerant.
2. Selectingtheinstallationlocation
2.1. Indoorunit
• Whereairowisnotblocked.
• Wherecoolairspreadsovertheentireroom.
• Whereitisnotexposedtodirectsunshine.
• Atadistance1mormoreawayfromyourTVandradio(topreventpicturefrom
being distorted or noise from being generated).
• Inaplaceasfarawayaspossiblefromuorescentandincandescentlights(sothe
infrared remote control can operate the air conditioner normally).
• Wheretheairltercanberemovedandreplacedeasily.
Warning:
Mounttheindoorunitintoaceilingstrongenoughtowithstandtheweightof
theunit.
2.2.
Wirelessremotecontrollermounting(ForSLP-2FAL*)
• Placeofmounting
• Whereitiseasytooperateandeasilyvisible.
• Wherechildrencannottouch.
• Mounting
Selectapositionabout1.2mabovetheoor,checkthatsignalsfromtheremote
controlleraresurelyreceivedbytheindoorunitfromthatposition(‘beep’or‘beep-
beep’receivingtonesounds).Afterthat,attachremotecontrollerholdertoapillar
or wall and set the wireless remote controller.
Inrooms whereinverter typeuorescent lampsare used,the signal fromthe
wirelessremotecontrollermaynotbereceived.
Note:
Thephrase“Wiredremotecontroller”inthisinstallationmanualrefersonlytothePAR-32MAA.Ifyouneedanyinformationfortheotherremotecontroller,
pleaserefertoeithertheinstallationmanualorinitialsettingmanualwhichareincludedintheseboxes.
RG79Y734H01_en.indd 2 2015/07/06 14:44:44