Note
Manufactured by:
Mitsubishi Electric Corporation
2-7-3 Marunouchi, Chiyoda-ku, Tokyo, 100-8310 Japan
Manufactured at:
Mitsubishi Electric Corporation Himeji Works
840 Chiyoda-machi, Himeji, Hyogo, 670-8677 Japan
Authorized Representative in the European Community:
Mitsubishi Electric Europe B.V.
Gothaer Str. 8, 40880 Ratingen, Germany
Type: Programmable Controller (Open Type Equipment)
Models: MELSEC FX3U series manufactured
from May 1st, 2005 FX3U-MR/ES(-A)
Where indicates: 16, 32, 48, 64, 80
FX3U-4HSX-ADP FX3U-2HSY-ADP
FX3U-FLROM-16 FX3U-FLROM-64L
FX3U-7DM
from June 1st, 2005 FX3U-232ADP FX3U-485ADP
FX3U-4AD-ADP FX3U-4DA-ADP
FX3U-4AD-PT-ADP FX3U-4AD-TC-ADP
FX3U-232-BD FX3U-422-BD
FX3U-485-BD FX3U-USB-BD
FX3U-FLROM-64 FX3U-CNV-BD
from November 1st, 2005 FX3U-MT/ES(-A)
FX3U-MT/ESS
Where indicates: 16, 32, 48, 64, 80
from February 1st, 2006 FX
3U
-128MR/ES(-A) FX
3U
-128MT/ES(-A)
FX3U-128MT/ESS
FX
3U
-
MR/DS FX
3U
-
MT/DS
FX3U-MT/DSS
Where indicates: 16, 32, 48, 64, 80
from April 1st, 2007 FX
3U
-232ADP-MB FX
3U
-485ADP-MB
from December 1st, 2007 FX3U-4AD-PTW-ADP
FX3U-4AD-PNK-ADP
from June 1st, 2009 FX3U-3A-ADP FX3U-CF-ADP
from August 1st, 2010 FX3U-8AV-BD
from September 1st, 2010
FX3U-MR/UA1 FX3U-MS/ES
Where indicates: 32, 64
from May 1st, 2011
FX3U-FLROM-1M
from February 1st, 2012 FX3U-ENET-ADP
Models: MELSEC FX2N series manufactured
from July 1st, 1997 FX2N-ER-ES/UL FX2N-ET-ESS/UL
Where indicates: 32, 48
FX2N-16EX-ES/UL FX2N-16EYR-ES/UL
FX2N-16EYT-ESS/UL
from April 1st, 1998 FX2N-48ER-DS FX2N-48ET-DSS
from August 1st, 1998 FX2N-48ER-UA1/UL
from August 1st, 2005 FX2N-8ER-ES/UL FX2N-8EX-ES/UL
FX2N-8EYR-ES/UL FX2N-8EYT-ESS/UL
from September 1st, 2010
FX2N-8EYR-S-ES/UL
For the products above, PLCs manufactured
before March 31st, 2002 are compliant with EN50081-2 (EN61000-
6-4) and EN50082-2
from April 1st, 2002 to April 30th, 2006 are compliant with EN50081-
2 (EN61000-6-4) and EN61131-2: 1994 +A11: 1996 +A12: 2000
after May 1st, 2006 are compliant with EN61131-2: 2007
Requirement for Compliance with LVD directive
The following products have shown compliance through direct
testing (of the identified standards below) and design analysis
(through the creation of a technical construction file) to the European
Directive for Low Voltage (2006/95/EC) when used as directed by
the appropriate documentation.
Type: Programmable Controller (Open Type Equipment)
Models: MELSEC FX3U series manufactured
from May 1st, 2005 FX3U-MR/ES(-A)
Where indicates: 16, 32, 48, 64, 80
from November 1st, 2005 FX3U-MT/ES(-A)
FX3U-MT/ESS
Where indicates: 16, 32, 48, 64, 80
from February 1st, 2006 FX3U-128MR/ES(-A)
FX3U-128MT/ES(-A)
FX3U-128MT/ESS
FX3U-MR/DS
Where indicates: 16, 32, 48, 64, 80
from September 1st, 2010
FX3U-MR/UA1
FX3U-MS/ES
Where indicates: 32, 64
Standard Remark
EN61131-2: 2007
Programmable controllers
- Equipment
requirements and tests
Compliance with all relevant aspects
of the standard.
EMI
Radiated Emission
Conducted Emission
EMS
Radiated electromagnetic field
Fast transient burst
Electrostatic discharge
High-energy surge
Voltage drops and interruptions
Conducted RF
Power frequency magnetic field
Standard Remark
EN61000-6-4: 2007
- Generic emission
standard
Industrial environment
EN50081-2: 1993
Electromagnetic
compatibility
Compliance with all relevant aspects
of the standard.
Emission-Enclosure port
Emission-Low voltage AC mains
port
Emission-Telecommunications/
network port
EN50082-2: 1995
Electromagnetic
compatibility
- Generic immunity
standard
Industrial environment
Compliance with all relevant aspects
of the standard.
RF immunity
Fast transients
ESD
Conducted
Power magnetic fields
EN61131-2: 1994
/A11: 1996
/A12: 2000
Programmable controllers
-Equipment
requirements and tests
Compliance with all relevant aspects
of the standard.
Radiated electromagnetic field
Fast transient burst
Electrostatic discharge
Damped oscillatory wave
EN61131-2: 2007
Programmable controllers
-Equipment
requirements and tests
Compliance with all relevant aspects
of the standard.
EMI
Radiated Emission
Conducted Emission
EMS
Radiated electromagnetic field
Fast transient burst
Electrostatic discharge
High-energy surge
Voltage drops and interruptions
Conducted RF
Power frequency magnetic field
Standard Remark
EN61131-2: 2007
Programmable controllers
-Equipment
requirements and tests
The equipment has been assessed
as a component for fitting in a
suitable enclosure which meets the
requirements of EN61131-2: 2007
Models: MELSEC FX2N series manufactured
from July 1st, 1997 FX2N-ER-ES/UL FX2N-ET-ESS/UL
Where indicates: 32, 48
FX2N-16EYR-ES/UL
from April 1st, 1998 FX2N-48ER-DS
from August 1st, 1998 FX2N-48ER-UA1/UL
from August 1st, 2005 FX2N-8ER-ES/UL FX2N-8EYR-ES/UL
from September 1st, 2010
FX2N-8EYR-S-ES/UL
For the products above, PLCs manufactured
before March 31st, 2002 are compliant with IEC1010-1
from April 1st, 2002 to April 30th, 2006 are compliant with EN61131-
2: 1994 +A11: 1996 +A12: 2000
after May 1st, 2006 are compliant with EN61131-2: 2007
Caution for compliance with EC Directive
Installation in Enclosure
Programmable logic controllers are open-type devices that must be
installed and used within conductive control boxes. Please use the
FX3U Series programmable logic controllers while installed in
conductive shielded control boxes. Please secure the control box lid
to the control box (for conduction). Installation within a control box
greatly affects the safety of the system and aids in shielding noise
from the programmable logic controller.
Caution for Analog Products in use
The analog special adapters have been found to be compliant to the
European standards in the aforesaid manual and directive. However,
for the very best performance from what are in fact delicate
measuring and controlled output device Mitsubishi Electric would like
to make the following points;
As analog devices are sensitive by nature, their use should be
considered carefully. For users of proprietary cables (integral with
sensors or actuators), these users should follow those
manufacturers installation requirements.
Mitsubishi Electric recommend that shielded cables should be used.
If NO other EMC protection is provided, then users may experience
temporary induced errors not exceeding +10 %/-10 % in very heavy
industrial areas.
However, Mitsubishi Electric suggest that if adequate EMC
precautions are followed with general good EMC practice for the
users complete control system, users should expect normal errors
as specified in this manual.
- Sensitive analog cable should not be laid in the same trunking
or cable conduit as high voltage cabling. Where possible users
should run analog cables separately.
- Good cable shielding should be used. When terminating the
shield at Earth - ensure that no earth loops are accidentally
created.
- When reading analog values, EMC induced errors can be
smoothed out by averaging the readings. This can be achieved
either through functions on the analog special adapter/block or
through a users program in the FX3U Series PLC main unit.
Incorporated Items
Check if the following product and items are included in the package:
(*1) The FX3U-M/ES-A becomes Chinese version.
1. Outline
1.1 Part names
Standard Remark
IEC1010-1: 1990
/A1: 1992
Safety requirements for
electrical equipment for
measurement, control, and
laboratory use
- General requirements
The equipment has been assessed
as a component for fitting in a
suitable enclosure which meets the
requirements of IEC 1010-1:
1990 +A1: 1992
EN61131-2: 1994 : 2007
/A12: 2000
/A11: 1996
Programmable controllers
- Equipment
requirements and tests
The equipment has been assessed
as a component for fitting in a
suitable enclosure which meets the
requirements of EN61131-2:
1994 +A11: 1996 +A12: 2000,
: 2007
Included Items
Main units
FX3U-16Mto
FX3U-128M
Product 1 unit
Dust proof protection sheet 1 sheet
Manuals [Japanese (*1)/English] 1 manual
Input/output extension units
FX2N-32E,
FX2N-48E
Product 1 unit
Extension cable 1 cable
Input/output number label 1 sheet
Input/output extension blocks
FX2N-8E,
FX2N-16E
Product 1 unit
Input/output number label 1 sheet
No. Name
[1] Top cover
[2] Battery cover
[3] Special adapter connecting hooks (2 places)
[4] Expansion board dummy cover
[5] RUN/STOP switch
[6] Peripheral device connecting connector
[7] DIN rail mounting hooks
[8] Model name (abbreviation)
[9] Input display LEDs (Red)
[10] Terminal block covers
[11] Extension device connecting connector cover
[12]
Operation status display LEDs
POWER Green On while power is on the PLC.
RUN Green On while the PLC is running.
BATT Red Lights when the battery voltage drops.
ERROR Red Flashing when a program error occurs.
Red Lights when a CPU error occurs.
[13] Output display LEDs (Red)
[1]
[2]
[3]
[9]
[10]
[11]
[12]
[13]
[8]
[4]
[5]
[6]
[7]