OPTIONAL
PARTS
E-210
INSTALLATIONMANUALFORA-MCONVERTER
Thismanualiswrittenonlyforthemodels
SAFETYPRECAUTIONS
●Afterinstallation,maketestoperationandconfirmthatitworksproperly,andexplainthesafetyprecautions,operationmethod,
andmaintenancetoyourcustomers.
Tellyourcustomerstokeepthisinstallationmanualtogetherwithoperationmanualwiththem,andwhentheygiveorsellthis
machinetootherpersonputthisinstallationmanualandoperationmanualwithit.
●Beforestartinginstallation,readthe"SafetyPrecautions"describedbelow.
●Thefollowingprecautionsmustbeobservedasitdescribestheseriousmattersforsafety.
●Thesafetyprecautionsaredescribedwiththedegreeofdanger.
WARNING
WARNING
CAUTION
Whenyouhandlewrong,itcanleadtodeathorseriousinjury.
Whenyouhandlewrong,itcanleadtoinjuryordamagetobuildingandfurniture.
The installation must be done by dealer or qualified person.
●Ifthecustomersdotheinstalltionbythemselvesanditisnot
perfectlyinstalleditcancausewaterleak,electricshock,orfire.
●Iftheinstallationisnotperfectlydone,itcancausewaterleak,
electricshock,orfire.
The installation must be done in accordance with this manual.
Never try any modification.
●Forrepair,askyourdealer.
Ifthemachineismodifiedorrepairedunperfectly,itcancausewater
leak,electricshock,orfire.
Never move or reinstall the machine by the customers.
●Iftheinstallationisnotperfectlydone,itcancausewaterleak,
electricshock,orfire.Askyourdealerorqualifiedperson.
Beforeelectricwiring
CAUTION
The wiring must be securely done by using proper cable. The wires should
be connected to the terminals not to have external force of the cable.
●Unperfectconnectionscancauseheatorfire.
The termial cover (panel) of the unit must be installed securely.
●
Unperfectinstallationcancausefireorelectricshockbydustorwater.
The electric installation must be done by qualified person in accordance
with this installation manual. Use the separate circuit only for this machine
and use rated voltage and circuit breaker.
●Iftheelectriccircuitpowerisnotsufficientorthewiringisnot
properlydone,itcancauseelectricshockorfire.
●Withoutacircuitbreaker,itcancauseelectricshock.
Install a circuit breaker depending upon the location.
Use standard wires which meet current capacity.
●Otherwise,itcancauseshort-circuit,heat,orfire.
Wires must not have tension.
●Itcancausesnipping,heat,orfire.
Put ground wire.
●Nevergroundtogaspipe,waterpipe,lightningconductor,or
telephonegroundwire.
Unperfrectgroundcancauseshort-circuit.
Use proper fuses
●Ifyouuselargersizefusesorneeldewire,itcancausefailureorfire.
Beforetestoperation
Turn the power on 12 hours or more before operation.
●Ifyoustartoperationassoonasthepoweron,itcancausefailure.
Neverturnthepoweroffduringseason.
Never operate the machine without panel or guard off.
●Itcancauseseriousinjurybeingcaughtbyrotatingpartorburnor
electricshockbyhighvoltagepart.
Never operate the machine without air filter off.
●Itcancausefailurebydust.
Never operate the switches with your hand wet.
●Itcancauseelectricshock.
Never touch refrigerant pipes while the machine running.
●Therefrigerantpipesbecomeshighandlowtemperaturewhilethe
machinerunning.Ifyoutouchthepipesbyhand,itcancause
chilblainorburn.
Never turn the power off as soon as the machine stops.
●Waitfor5minutesormore.Itcancausewaterleakorfailure.
CAUTION
A:
B:
C:
D:
E:
F:
G:
H:
PUHZ-RP1.6/2VHA
PUHZ-RP35/50VHAtype
PUZ-A18NHA,PUY-A12/18NHA
PUHZ-RP2.5〜6VHA(-A)
PUHZ-(H)(R)P60〜140VHAtype
PUZ-A24〜42NHA,PUY-A24〜42NHA
PUHZ-RP100〜140VKA
PU(H)-P1〜4VGA(A),P25〜100VGAA
PU(H)-P1.6〜6YGA(A),P35〜140YGAA
PUH-P8/10YE,P8/10MYA,P200/250MYA
PUHZ-RP4〜6YHA
PUHZ-(H)RP100〜140YHAtype
PUHZ-RP100〜140YKA
PUHZ-RP8/10YHA(-A),RP200/250YHA(-A)
PUHZ-RP200/250YHA1(-A)
PU(H)-P71/100VHA,PU(H)-P71〜140YHA
PUHZ-P200/250YHA(3),PUHZ-RP200/250YHA2,PUHZ-RP200/250YKA
M-NET Converter PAC-SF81MA-E