• On/Off switches control the 13A sockets only
• USB charger sockets are independent of the 13A sockets and cannot be switched off
• Ensure that the mains supply is switched off and the circuit fuses are removed or circuit
breakers switched off
• To maintain the finish of this product, periodically wipe over with a dry soft cloth
• Before installation/maintenance, ensure the mains supply is switched off and the circuit
fuses are removed or circuit breakers switched off
• This product must be installed in accordance with the latest edition of the IEE Wiring
Regulations and current Building Regulations. If in any doubt, consult a
qualified electrician
• 230V 50Hz
• Do no overload this accessory or subject it to conditions outside its rating
• Please recycle
• For indoor use only
• 220-240V ~50-60Hz
• 13A
USB charger specification
• Output voltage: 5V DC
• Output current: Max. 2100mA
• Caution: the USB sockets are designed for charging portable USB devices only
• 1 x 13A 2G mounting switched socket with dual USB charger
• 1 x fixing pack
• 1 x installation guide
INSTALLATION
OPERATION
MAINTENANCE
SAFETY
SPECIFICATION
CONTENTS
PLEASE READ THESE BEFORE COMMENCING INSTALLATION
• This is a Class I product and must be earthed
• These instructions should be read carefully and retained after installation for further
reference and maintenance
1. Carefully prize off the
screw caps with a flat-head
screwdiver
2. Unscrew the cover screws and
remove the front cover (fig.1)
3. Place the socket in position
and mark the 4 fixing holes as
shown in (fig.2)
4. Drill the holes for the fixings
ensuring not to infringe with
any joists, gas/water pipes or
electrical cables that may be
hidden behind the surface
5. Thread the mains cable through
the cable entry hole and rubber
grommet provided
6. Secure the unit to the mounting
surface. Subject to the surface
foundation material, please
ensure the correct fixings
are used
7. Connect the supply wires to
the terminal block (fig.3). This
product must be earthed.
Connect the mains cable to
the terminal block provided
ensuring correct polarity is
observed. BROWN- LIVE.
BLUE-NEUTRAL. GREEN/
YELLOW-EARTH
BLUE (N)*N NEUTRAL
TERMINAL BLOCK WIRING
230V 50HZ SUPPLY SK002
GREEN/YELLOW*EARTH GREEN/YELLOW SLEEVED COPPER
BROWN (L)*L SWITCHED LIVE