Mobility Research GKmini User manual

GKmini
USER MANUAL
Motorized Walking Surface


3
Table of Contents
1. Safety Instructions............................................................................ 4
2. About GKmini................................................................................... 5
2. Assembly - LiteGait®........................................................................ 6
3. Assembly - Handle Bars................................................................... 7
5. Operation .......................................................................................... 8
6. Care & Maintenance......................................................................... 9
7. Troubleshooting. ............................................................................... 10
8. Specications.................................................................................... 11
9. Resource Directory ........................................................................... 11
10. Warranty .......................................................................................... 13
GKmini
IMPORTANT: All features subject to change without noce.

4
1. Safety Instrucons
IMPORTANT SAFETY INSTRUCTIONS
• WARNING: READ ALL INSTRUCTIONS BEFORE USING THE WALKING SURFACE.
• CAUTION: Health related injuries may result from incorrect or excessive use of exercise equipment.
WARNING: To reduce the risk of burns, res and electric shock or injury to persons, follow these instructions.
• Attach the safety magnet to LiteGait® or handle bars prior to use.
• Do not exceed maximum weight of 350lbs.
• Avoid exiting treadmill while leaving the tread belt in motion.
• Do not allow power cable or hand held cables to contact walking surface belt during operation. Cables must be
routed away from the walking surface belt through restraining clip (See Step 4 of Assembly Instructions on page 6).
• Never walk or jog backwards on the treadmill without the aid of a clinician and support from LiteGait®
• This equipment should never be left unattended when in operation
• Wear shoes with rubber or high traction soles. Do not use shoes with heels, leather soles, cleats or spikes. Make sure
no stones are embedded in the soles. Do not use this product in bare feet. Keep all loose clothing, shoelaces and
towels away from moving parts.
• Do not operate the Walking Surface while being covered with a blanket, plastic, or anything that insulates or stops
airow.
• Close supervision is necessary if the Walking Surface is used by children, or used near children or incapacitated
individuals.
• Use this Walking Surface only for its intended use as described in this manual.
• Do not use attachments not recommended by the manufacturer.
• Never operate if the power cord or plug is damaged, if it is not working properly, if it has been damaged or dropped,
or if it has been submerged in water. In these cases, a qualied service technician should examine the walking
surface.
• Do not use the power cord as a handle for transporting.
• Do not run the power cord along the side or under the treadmill.
• Keep the power cord away from heated surfaces.
• Never drop or insert any object into any opening.
• Do not reach into or underneath the unit, or tip it on its side during operation.
• Use indoors only.
• Do not operate where aerosol (spray) products are being used or where oxygen is being administered.
• Allow only trained personnel to service this equipment.
• Never use near water or while wet. Using this Walking Surface around a pool, hot tub or sauna will void the warranty.
And may cause serious injury or death.
• Avoid the possibility of bystanders being struck or caught between moving parts by making sure that they are out of
reach
LiteGait® GKmini Handlebars Without LiteGait® or GKmini
WARNING: GKmini Walking Surface REQUIRES use with the LiteGait® or GKmini handlebars. Operation without LiteGait®
or GKmini handlebars may result in injury to user. The walking surface is only safe when used properly with the
appropriate LiteGait® products. GKmini includes a magnet that must be attached to your LiteGait® following the
provided instrctions. This safety feature may not be tampered with.

5
2. About GKmini
Basic Guidelines for Setting Up Your Treadmill
After removing the treadmill from the packaging, place your treadmill on a clean, level surface. Make sure the electrical
cord easily reaches a grounded three-pronged outlet . Do not allow the treadmill assembly to rest on the cord.
Important Electrical Requirements
Your GKmini requires a 120-240V power outlet that allows for up to 6 amp of current draw.
Do not modify the plug provided with the treadmill if it will not t the outlet. Have a proper outlet installed by a qualied
Hand Control Console
LiteGait Magnet Lanyard
Ground Power Cable
Walking Surface
Removable Handle Bars
Release
Knob

6
2. Assembly - LiteGait®
1. Remove the protective packaging
materials and discard.
2. Plug the power cord into the
appropriate receptacle under the belt.
3. Plug the hand control into the
appropriate receptacle under the belt.
5. Wrap the lanyard attached to the
magnetic safety key around the upright
in your LiteGait®.
6. Feed the magnet through the wire
loop.
7. Wheel the GKmini under the
LiteGait®.
8. Place the magnet in the receptacle
on the top surface. GKmini is ready for
Power
Cable Hand
Control
On / Off
Switch

7
4. Place the magnet in the receptacle on
3. Assembly - Handle Bars
1. Insert Handle Bar into the front of GKMini
1. Place Handle Bars near front end
of GK mini
2. Lower Handle Bars into the Han-
dle Bar bracket
3. Pull knob out and push Handle
Bars until the knob clicks securing it
WARNING
USE GKMINI only under LiteGait or with
Handlebars.
Warning
Use only when supported in LiteGait® or with GKMINI Handlebar
Do not exceed 350lb user weight limit
Indoor use only, do not use near water
Unplug treadmill before moving, cleaning or performing maintenance on the GKMINI
Children require adult supervision

8
Attach magnetic safety key lanyard to LiteGait®.
Connect magnetic safety key to Walking Surface.
Treadmill Use Preparation
Operation
NOTE: The belt starts at the lowest speed 0.1mph (0.2 kph) unless the Start/Stop button was pushed since the treadmill
was last powered down when the belt starts at the last displayed speed.
Press the
button on the handset while the belt is running.
The speed of the walking belt will decrease by 0.1 mph (0.2kph) per
Press the
button on the handset while the belt is running.
The speed of the walking belt will increase by 0.1 mph
(0.2kph) per button press, to a maximum of 3.0 mph (6.0
kph).
Press the
button on the handset while the belt is stopped.
The walking belt will start either at the lowest speed
0.1mph (0.2 kph) or, if the Start/Stop button has been
pushed since the treadmill was last powered down, the
walking belt will start at the last displayed speed.
Press the button on the handset while the belt is running.
Stand carefully on the walking belt while supported by LiteGait®
Display
Hand control display cycles between time of session, distance travelled and speed of walking belt.
Time (s) Distance (m) Speed (kph)
Pressing speed buttons returns display to speed display.
5. Operaon

9
6. Care & Maintenance
Care & Maintenance
It is important to perform the minor maintenance tasks described in this section. Failure to maintain the Walking Surface as
described here could void the Warranty. To reduce the risk of electrical shock, always unplug the unit from its power source
before cleaning or performing any maintenance tasks.
Maintenance Schedule:
1. Inspect walking surface upon each use for wear and tear, and soiled surface.
2. Lubricate the walking belt annually
3. Adjust belt tension only if required.
Cleaning the Equipment:
MOBILITY RESEARCH recommends the walking surface be cleaned before and after each workout. Use mild soap and
water to dampen a soft cloth and wipe all exposed surfaces. This helps remove any dust or dirt.
CAUTION: Do not use any acidic cleaners. Doing so will weaken the paint or powder coatings and may void the Warranty.
Never pour water or spray liquids on any part of the device. Allow the walking surface to dry completely before using.
Frequently vacuum the oor underneath the unit to prevent the accumulation of dust and dirt, which can affect the smooth
operation of the unit.
When cleaning the exterior of the unit, a non-abrasive cleaner and soft cotton cloth are strongly recommended. At no time
should cleaner be applied directly to any part of the equipment; use nonabrasive cleaner of soft cloth and then wipe the
unit.
Adjustment of Walking Surface Belt tension/Alignment.
The walking belt may require minor adjustment as a result from shipping or extended use. To adjust the tension/alignment of the walking
surface belt insert the provided allen key (previous versions use a Phillips head screw driver) and ghten/loosen the belt alignment screws
on the front face of the walking surface as show in pictures below.
To increase/decrease belt tension ghten/loosen both alignment screws evenly.
To adjust belt alignment, ghten/loosen the adjustment screw to cause the belt to move away from/towards the screw. Tightening the
Long Term Storage:
When the treadmill is not in use for any length of me, ensure the power cord is unplugged from the power source and posion the power
and data cords so that they will not become damaged or interfere with people or other equipment.
Tighten le screw to move belt from le toward center. Tighten right screw to move from right toward center.

10
Problem: Treadmill belt slips when walking on it
Solution: Tighten the belt using the instructions below:
Set the treadmill at and tension and align the belt according to the following procedures:
1. Connect power and pendant controller to treadmill. Then connect magnetic key.
2. Keeping the belt centered on both rollers, use a Phillips screwdriver to tighten the tensioning screws evenly until you
can no longer easily see the slots in the channels behind the ends of the rollers.
3. Turn on the treadmill, starting at its slowest speed, and make sure everything is running smoothly with no out-of-the-
ordinary noises. If the belt quickly runs to one side, tighten the tensioning screw on that side until the belt slowly
centers.
4. Use one foot to apply all your weight to the belt. If the belt sticks to the deck and stops moving, tighten each tensioning
screw in 1/2-turn increments the same amount. Then, retest.
5. When the belt stops sticking from one foot pressure, speed the treadmill up to 1 mph (9 presses of the speed up
command).
6. Walk heavily on the treadmill. If the belt sticks, tighten each tensioning screw 1/2 turn and repeat.
7. When properly tensioned, look at how the edge of the belt is running relative to the trim ledge. If it is angling toward
the right at the front of the treadmill, loosen the tensioning screw on the right 1/2 turn. Using either the screwdriver or
the 3/16" Allen wrench, tighten the alignment screw on the front right and of the roller 1/2 turn. Check again and
repeat if necessary.
FOR ADDITIONAL ASSISTANCE TROUBLESHOOTING PLEASE FEEL FREE TO CONTACT
MOBILITY RESEARCH
TECHNICAL SUPPORT 1-
800-332-9255
Spare Parts List
NOTE: Pricing Subject to change without notice.
7. Troubleshoong
2101 MTHB-H21 Handlebar for GKMINI21 -
insert style
400EU
PGKM21-WSB Walking Belt for GKMINI21 255EU
2018 (PGKM-PC-A) Grounded Power Cable for
GKMini (country specific)
50EU
1738 (PGKM-R-A) Hand Set for GK Mini Walk-
ing Surface
545EU
1795 (PGKM-SKM) Safety Key for GK Mini
(Magnet)
25EU

11
Authorized European Community Representave
Mobility Research
Lillehøjvej 29
DK-8600 Silkeborg
Denmark
Walking Surface Width 18” 21"
Walking Surface Length 40” 40"
Treadmill Width 21” 24"
Treadmill Length 42” 42"
Foot Print 21”x42”24” x 42”
Shipping Weight 60lb 70lb
Maximum User Weight 350lb
Incline Range N/A
Drive Motor Brushless
Speed Range 0.1-3.0
Step-Up Height 6”
Power Requirements 110-240 VAC, 6A 50/60 Hz
Note: Dimensions are approximate and are subject to change without noce.
8. Specicaons
Phone/Fax Website: Email Directory
Phone :
800.332.WALK (9255)
Toll free in U.S. and Canada
Fax:
480-829-0737
LiteGait.com
LiteGait.org
Service & Parts [email protected]m
Clinical Support [email protected]m
Educaon Educa[email protected]
Sales [email protected]
9. Resource Directory

12
SECTION LEFT INTENTIONALLY LEFT BLANK

13
All MOBILITY RESEARCH products are distributed by
MOBILITY RESEARCH and are warranted to the original
registered product purchaser and the parts of the TRUE
product (the “Product”) listed below, under normal use
and service, shall be free of manufacturing defects in
workmanship and materials only for the period of time
beginning from the original date of purchase set forth
Frame 1 Year
Motor
Drive Motor
Motor Controller
1 Year
Parts
Electrical
Wear Items
Cosmetics
1 Year
Labor 1 Year
Losses due to work stoppage, lost revenues, damages
due to neglect or abuse ARE NOT covered by this
warranty. Shipping and handling charges ARE NOT
covered by this warranty. Repairs may be conducted at
factory at the discretion of Mobility Research.
If a problem caused by a manufacturing defect occurs
that cannot be resolved by the replacement of parts the
problem will be resolved by replacing the current
device with a remanufactured replacement device
(either the same model or one of comparable quality).
THIS WARRANTY AND REMEDIES SET FORTH ABOVE ARE
EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES,
REMEDIES AND CONDITIONS, WHETHER ORAL OR
WRITTEN, EXPRESS OR IMPLIED. MOBILITY RESEARCH
SPECIFICALLY DISCLAIMS ANY AND ALL IMPLIED
WARRANTIES, INCLUDING, WITHOUT LIMITATION,
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE. IF MOBILITY RESEARCH CANNOT
LAWFULLY DISCLAIM IMPLIED WARRANTIES UNDER THIS
LIMITED WARRANTY, ALL SUCH WARRANTIES, INCLUDING
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE ARE LIMITED IN DURATION TO THE
DURATION OF THIS WARRANTY. NO MOBILITY RESEARCH
RESELLER, AGENT, OR EMPLOYEE IS AUTHORIZED TO
MAKE ANY MODIFICATION, EXTENSION OR ADDITION TO
THIS WARRANTY. MOBILITY RESEARCH IS NOT
RESPONSIBLE FOR DIRECT, SPECIAL, INCIDENTAL OR
CONSEQUENTIAL DAMAGES RESULTING FROM ANY
BREACH OF WARRANTY OR CONDITION OR UNDER ANY
Please activate your warranty by providing the
following information. This information will allow us to
notify you for product updates, recall information,
clinical support, technical support, maintenance
information and to receive our E-Newsletter. You may
visit our website at http://www.litegait.com/
warranty.html and ll the registration form or ll in the
information below and mail or fax back. (Keep a copy
Write Your Serial Number Here
Your serial number will be located on the front of the
treadmill motor cover
EXAMPLE OF SERIAL NUMBER STICKER
Model
Date of Purchase
Facility Name
Department Used
Address
Phone #
Fax #
Clinical Contact
Phone #
Email
Biomed Contact
Phone #
Email
(2019 US)
10. Warranty
Table of contents
Other Mobility Research Treadmill manuals