MOBILUS C-MR IP44 User manual

User Manual of MOBILUS C-MR IP44
external receiver
www.mobilus.plWersja 1.0ENG, 210401

1. IMPORTANT INFORMATIONS
• When unpacking the unit, make sure that there is no damage in the transport. If so, you
should immediately inform the supplier.
• Read the operating manual carefully before use
• MOBILUS C-MR module should be powered by 230 V ~, 50 Hz. Its installation should only
be carried out by persons with electrical qualifications according to the enclosed electrical
diagram in accordance with all applicable regulations.
• MOBILUS C-MR module is designed to work with all COSMO / COSMO | 2WAY series remote controls.
• The range of the radio control is limited by regulations for maximum power of the remote
control and the conditions of the installation of the equipment. When designing the location
of the remote control, consider limiting the range to about 20m by 2 walls.
• Declaration of Conformity:
We declare under our sole responsibility that the MOBILUS C-MR complies with the
following European Directives:
1. 2014/53 / EU RED Radio Directive;
2. 2014/30 / EU Electromagnetic Compatibility Directive.
3. 73/23/EWG Low Voltage Directive.
2. ENTRY INTO THE MODULE PROGRAMMING MODE
Turn off and turn on the power supply of the MOBILUS C-MR
IP44 module twice, until the connected actuator performs one
sequence of micro movements down / up, confirming that the
module enters the PROGRAMMING MODE.
WARNING! If within 20 seconds no programming will be
performed, the MOBILUS C-MR IP44 radio module automati-
cally exits from the programming mode. Connected actuator
executes one sequence of noticeable and audible micro
movements down.
1 s.
BEEP! BEEP!
PILOT 2
1 s.
b
ON OFFON OFF
2x
2

3. LOADING THE MASTER-A * CODE TO THE RECEIVER MEMORY
1. Enter the MOBILUS C-MR IP44 PROGRAMMING MODE.
2. Press and hold the STOP and UP buttons
simultaneously on the remote control until the connected
actuator executes one sequence of noticeable and audible
micro movements down / up.
3. The MASTER-a code has been loaded into memory and
the module goes to the WORK MODE. Now, with the
MASTER remote control, you can operate the units or enter
the PROGRAMMING MODE to load more remote controls.
BEEP! BEEP!
PILOT 2
1 s.
b
5 s.
BEEP! BEEP!
WARNING In the case of a multi-channel remote control
select only one channel to be MASTER.
NOTE For the convenience of programming, it is recom-
mended that each COSMO | C-MR IP44 module had its
own separate MASTER (remote control (separate channel
for multi-channel remotes). Avoid situations where several
COSMO | C-MR IP44 modules remote controls will have
common MASTER (shared channel).
BEEP! BEEP!
MASTER
1 2 3 4 5
5 s.
BEEP! BEEP!
PILOT 2
1 s.
a b
1 2 3 4 5 1 2 3 4 5
b
a
*MASTER - remote control or channel (in the case of a multi-channel remotes) loaded first into
the memory of the MOBILUS C-MR IP44 module. Allows you to program further remote controls.
3

4. PROGRAMMING OF THE SECOND AND EVERY OTHER REMOTE CONTROL
1. On the MASTER remote control, simultaneously press and hold the STOP and UP until the
connected actuator executes one sequence of noticeable and audible micro movements down / up
confirming the entrence of the receiver in the PROGRAMMING MODE - Fig. 4a.
2. On the second remote control (for the multi-channel remote control, select the channel
you want to program), press and hold both STOP and UP buttons simultaneously, until the
connected actuator performs one sequence of noticeable and audible micro movements
down / up. The remote (channel) was loaded into the receiver’s memory - Fig. 4b.
Fig. 4
MASTER PILOT 2a b
Repeat step 2 to load the next remote control. If, however, no programming operation is started
within 20 seconds, the module automatically returns to operating mode. Return to operating
mode can also be performed manually using MASTER. In such a situation, press and hold the
STOP and UP MASTER buttons. In both cases, the return to operating mode will be confirmed
by a single sequence of micro movements down / up of the connected actuator.
4

5. CHANGING THE DIRECTION OF THE ACTUATOR
1. If you press the UP button on the remote control and the armor goes down, change the
direction of rotation of the drive. At the same time, press and hold:
a ) on the remote control COSMO | HM, | HB, | G3+, | WT9, | WT buttons STOP and DOWN - Fig. 5b;
b ) on the remote control COSMO | HT, | H24,| H1, | H5, | G, | W1, | W7 buttons DOWN and UP - Fig. 5c;
c ) on the remote control COSMO | HCT UP and F3 buttons - Fig. 5d;
until the drive executes one sequence of micro down / up moves.
2. Check the UP / DOWN buttons - Fig. 5e.
rys. 5
a e
b
c
d
5

6. REMOVAL OF INDIVIDUAL REMOTES (CHANNELS)
It is possible to delete only one of the programmed remotes (not for MASTER remote).
To do this:
1. On the MASTER, press simultaneously and hold the STOP and UP buttons until the
connected actuator executes one sequence of noticeable and audible micro movements
down / up, confirming the receiver’s entrance into the programming mode - Fig. 6a.
2. On the remote control (channel) that you want to delete, press and hold the STOP and UP
buttons simultaneously until the connected actuator performs one sequence of noticeable
and audible micro movements down / up, confirming the removal of the pilot code from the
actuator memory - Fig. 6b.
Fig. 6
MASTER PILOT 2a b
WARNING! Repeat step 2 to proceed to remove the next remote control. However, if within
20 sec. no programming operation is started, the receiver automatically returns to operating
mode. Return to operating mode can also be performed manually using the MASTER. In such
a situation, simultaneously press and hold the STOP and MASTER buttons until the connected
actuator executes one sequence of noticeable and audible micro movements down / up. In
both cases, the return to operating mode will be through one sequence of micro down / top
moves of the connected actuator.
6

7. CONNECTING THE ADDITIONAL SWITCH / DRIVER
1. Connect the MOBILUS C-MR IP44 module according to the diagram in - Fig. 7.1.
2. Place the MOBILUS C-MR IP44 module in the shutter box. Use the two protruding handles with
holes for assembly.
3. Position the antenna properly (as far as possible from metal parts).
4. Switch on the mains voltage.
Fig. 7.1
L1
N
PE
N
PE
230V~ 50Hz
a
L1
N
PE
N
PE
230V~ 50Hz
a c
b
L1
N
PE
N
PE
230V~ 50Hz
a
b
L1
N
PE
N
PE
230V~ 50Hz
a c
b
c
b
7

8. REPEATER FUNCTION
SIGNAL REPEATER - This feature allows you to expand the radio control area. The MOBILUS C-MR
IP44 module with the repeater function enabled receives signals from the controller or actuators and
passes them forward. Thanks to the furthest located receivers which are not within the controller can
receive and transmit information through modules located indirectly. Turn on the repeater function:
1. Press the STOP and UP buttons simultaneously on the MASTER until the connected actuator executes
one sequence of noticeable and audible micro movements down / up, confirming entry into the
PROGRAMMING MODE.
2. On the remote control, press the button sequence: UP, STOP, DOWN, UP, STOP, DOWN. Activation of
the repeater function will cause three sequences of DOWN-UP micro-movements by the actuator.
3. Repeat step 1 to deactivate the repeater function. Then press the button sequence: UP, STOP,
DOWN, UP, STOP, DOWN - confirmation of deactivation is the execution of two sequences of
micro-DOWN-UP movements by connected actuator.
WARNING! Turn on the repeater function only on devices that are within range of the signal
range. Because of the efficient work, we recommend that you enable the signal repeater
function on up to three devices in the facility. Unreasonable inclusion of signal repeater on
many devices may cause interference in all radio equipment.
8
Fig. 8
b
MASTER
a
2X

9
9. BIDIRECTIONALITY
MOBILUS C-MR IP44 with two-way communication with the remote control allows control of
the state of shutter position ( eg. open, closed, intermediate level, overload detection ).
Proper operation of bidirectional communication requires the use of pilots with bidirectional
communication.
Remote controls supporting two-way communication: MOBILUS COSMO | HCT, COSMO | G3+,
COSMO | HM, COSMO | HB, COSMO | WT9, COSMO | WT.
10. BIDIRECTIONAL - INFORMATION ABOUT THE POSITION OF THE BLIND
MOBILUS C-MR IP44 transmits information about the end position and intermediate position
blinds to remote controls. The mode is switched on automatically - there is no possibility of
deactivation.
11. BI-DIRECTIONAL - OVERLOAD INFORMATION
MOBILUS C-MR IP44 transmits information to remotes about overload - for example, it may be
related to a housing lock occurring at the time of raising or lowering. Mode is factory-setted - it
is possible to turn off.
Enable / disable of overload detection:
1. At the MASTER remote control press and hold the STOP and UP buttons simultaneously
until the connected actuator performs one sequence of noticeable and audible micro
movements down / up confirming the receiver input into the programming mode - Fig. 11a.
2. On the MASTER, press the STOP button and hold until the actuator connected to the
MOBILUS C-MR IP44 module will perform two sequences of noticeable and audible micro
movements down / up. Overload detection active - Fig. 11b.
3. To stop the overload detection, repeat step 1. Then press the STOP button on the MASTER
control and hold until the actuator connected to the MOBILUS C-MR IP44 module will
perform 1 sequence of noticeable and audible micro moves down / up - Fig. 11c.

10
12. PRODUCT DESCRIPTION
1 2 3 4 5 1 2 3 4 5
b
a
Cable description:
BLUE 1 - neutral;
BLUE 2 - neutral;
GREY L- phase / power;
BLACK L - phase - to the drive;
BROWN L - phase - to the drive;
The drive is connected to one of the blue
(common), black and brown wires.
It doesn’t matter which blue is feeding
and which goes to the engine - they are
both connected inside.
CONTINUED 11. BI-DIRECTIONAL - OVERLOAD INFORMATION
Fig. 11
b
MASTER
a
2x
c

11
HCT HB HM G3+
13. CONTROL REMOTES - „COSMO” SERIES
WT WT9 L1 L5

MOBILUS MOTOR Spółka z o.o.
ul. Miętowa 37, 61-680 Poznań, PL
tel. +48 61 825 81 11, fax +48 61 825 80 52
VAT NO. PL9721078008
www.mobilus.plW1.1PL, 181128
5906453 473437
230 V~ 50 Hz
63
29 1.5 6
17
73
81
Table of contents
Other MOBILUS Receiver manuals