D. FIT TEST
1. Use any Moldex disposable N, R or P series class disposable
respirator or any Moldex half mask respirator with any N, R
or P series filter.
Have the test subject put on and adjust the respirator per the
instructions provided with the respirator. Have the subject
select the size respirator that provides the best fit. The subject
may find a mirror useful in the adjustment process. The subject
should wear the respirator at least five (5) minutes before
starting the test.
2. Instruct the subject to put on and position the hood as
before and breathe with their mouth slightly open and
tongue extended.
3. Using the nebulizer labeled BITREX Fit Test Solution, inject the
fit test aerosol into the hood. The same number of squeezes is
required as was necessary to elicit a response in the threshold
sensitivity screening test, i.e., 10, 20 or 30 squeezes.
4. To maintain an adequate concentration of aerosol during the
test, one half of the initial number of squeezes should be
injected again every 30 seconds (i.e., 5, 10, or 15)
throughout the test.
5. After injecting the aerosol initially, ask the test subject to
perform the following exercises for 60 seconds each:
(a) Normal breathing.
(b) Deep breathing.
(c) Turning head from side to side, stopping at each end of
travel for one or two breaths.
(d) Moving head up and down, stopping at each end of
travel for one or two breaths.
(e) Talking, reciting the alphabet, or reading a prepared
text (the Rainbow Passage is recommended, see below).
(f) Jogging in place.
(g) Normal breathing.
6. Instruct the subject to indicate if they detect the bitter taste at
any time during the test.
7. If the entire test is completed without the subject detecting
the bitter taste of the aerosol, the test is passed and
the respirator’s fit on that individual is judged adequate.
8. At any time during the test, if the subject detects the bitter
taste of the aerosol the test is stopped at this point. When
this occurs, the fit of the respirator on the subject is judged
inadequate.
9. If the test is failed, before retesting the subject, a 15-minute
waiting period must be observed and the taste sensitivity
screening test must be performed again. Test again with same
Moldex model.
10. If the second test fails, repeat tests with another size and/or
model Moldex respirator.
11. Document results of fit tests for each employee.
RAINBOW PASSAGE
OSHA
This fit test meets the performance criteria for fit testing half mask
respirators under current OSHA Standards.
OSHA regulation 1910.134 (f) requires that the user be fit
tested before being assigned a respirator.
CLEANING
Immediately after completing the test, discard any unused solu-
tions. Rinse the nebulizers with warm water to prevent clogging.
Wipe inside of the hood with a damp cloth or paper towel to
remove any deposited Test Solution.
FOR TECHNICAL ASSISTANCE CALL MOLDEX
TECHNICAL SERVICE DEPARTMENT
+1 (800) 421-0668 ext. 512/550, or +1 (310) 837-6500 ext. 512/550.
LIMITED WARRANTY IMPORTANT NOTICE TO PURCHASER
This limited warranty is made in lieu of the warranties of mer-
chantability, fitness for particular purposes and all other war-
ranties, express or implied. There are no other warranties which extend
beyond the description on the face hereof. The physical standards and specifica-
tions of Moldex will be met by products sold. Exclusive Remedies: damages
for the breach of this limited warranty are limited to the replacement of such quanti-
ty of Moldex, products proved to be defectively manufactured. Except as provided
above, Moldex shall not be liable or responsible for any loss, damage, or liabili-
ty, direct, indirect, incidental, special, or consequential, arising out of sale, use, or
misuse, or the inability to use products by the user.
DISTRIBUTED BY:
When the sunlight strikes raindrops in the air, they act like a
prism and form a rainbow. The rainbow is a division of
white light into many beautiful colors. These take the shape
of a long arch, with its path high above, and its two ends
apparently beyond the horizon. There is, according to legend,
a boiling pot of gold at one end. People look, but no one
ever finds it. When a man looks for something beyond his
reach, his friends say he is looking for the pot of gold at the
end of the rainbow.
MOLDEX-METRIC, INC.
10111 W. Jefferson Blvd. Culver City, CA 90232
+1 (800) 421-0668 or +1(310) 837- 6500 FAX +1 (310) 837- 9563
CANADIAN CUSTOMER SERVICE
TEL: +1 (310) 837-6500, Ext. 517
Fax: +1 (310) 837-9563
Made in the U.S.A. 9700-702 REV H 07/08
Moldex and Ideas that wear well are registered trademarks.
The PVC-Free logo and the mesh design are trademarks of Moldex-Metric, Inc.
U.S. Patents #D285,374 and #4,850,374.
Made in the U.S.A. 9700-702 REV I 12/09
Ideas that wear well.
®