4
Troubleshooting
When an error occurs, the Charging and Complete
LEDs blink together. In this case, repeat the charging
process. If the error still occurs, repeat the process
with a new battery. If there is a problem after the
second repeat charge, call Service.
In between charges, remove the battery, wait for the
lights to stop flashing, then re-insert the battery.
Specifications
Operating Limits
Temperature 32°F to 104°F (0°C to 40°C)
Humidity 5% to 90% non-condensing
Storage Limits
Temperature -40°F to 158°F (-40°C to 70°C)
Humidity 5% to 90% non-condensing
Charger
Length: 11.8” (300.0 mm)
Width: 6.25” (158.75 mm)
Height: 2.75” (70.0 mm)
Input: 12 to 16 VDC/50W
Weight: 4.55 lbs. (2.06 kg)
Power Supply
Input: Universal switching power supply, 90
to 264 VAC, 50/60 Hz.
Output: 12 VDC/80W max