manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Monarch
  6. •
  7. Transmitter
  8. •
  9. Monarch 433TSPW2K User manual

Monarch 433TSPW2K User manual

Other Monarch Transmitter manuals

Monarch 295SEPC1K User manual

Monarch

Monarch 295SEPC1K User manual

Monarch 433TSPW1K User manual

Monarch

Monarch 433TSPW1K User manual

Monarch 433TSPW2KC User manual

Monarch

Monarch 433TSPW2KC User manual

Monarch 433TSPW2K User manual

Monarch

Monarch 433TSPW2K User manual

Monarch Transmitter Solutions 418ELPW2K User manual

Monarch

Monarch Transmitter Solutions 418ELPW2K User manual

Monarch 295SEPC1K User manual

Monarch

Monarch 295SEPC1K User manual

Monarch 318DOPW1K-C User manual

Monarch

Monarch 318DOPW1K-C User manual

Monarch 295SEPA2K User manual

Monarch

Monarch 295SEPA2K User manual

Monarch 295SEPC2K User manual

Monarch

Monarch 295SEPC2K User manual

Monarch 318LIPW2K User manual

Monarch

Monarch 318LIPW2K User manual

Popular Transmitter manuals by other brands

NIVELCO EasyTREK SCA-300 Series Programming manual

NIVELCO

NIVELCO EasyTREK SCA-300 Series Programming manual

Honeywell 5816WMBR installation instructions

Honeywell

Honeywell 5816WMBR installation instructions

Kamstrup READy MTU Installation and operation guide

Kamstrup

Kamstrup READy MTU Installation and operation guide

Omega ZW Series user guide

Omega

Omega ZW Series user guide

ABB Field 264H Instructions for installation

ABB

ABB Field 264H Instructions for installation

Alinco DJ-V17T Service manual

Alinco

Alinco DJ-V17T Service manual

Dejero EnGo 3x manual

Dejero

Dejero EnGo 3x manual

Rosemount 4600 Reference manual

Rosemount

Rosemount 4600 Reference manual

Speaka Professional 2342740 operating instructions

Speaka Professional

Speaka Professional 2342740 operating instructions

trubomat GAB 1000 instruction manual

trubomat

trubomat GAB 1000 instruction manual

Teledyne Analytical Instruments LXT-380 instructions

Teledyne Analytical Instruments

Teledyne Analytical Instruments LXT-380 instructions

Rondish UT-11 quick start guide

Rondish

Rondish UT-11 quick start guide

MG 10JRE instruction manual

MG

MG 10JRE instruction manual

Burkert 8177 operating instructions

Burkert

Burkert 8177 operating instructions

Firetide HotPort 3203 Hardware installation guide

Firetide

Firetide HotPort 3203 Hardware installation guide

Tele Radio T9-02 User instructions

Tele Radio

Tele Radio T9-02 User instructions

Rotronic HygroFlex HF3 Series user guide

Rotronic

Rotronic HygroFlex HF3 Series user guide

Jamara FCX6 Pro Tel Instruction

Jamara

Jamara FCX6 Pro Tel Instruction

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

1A - General information
The Transmitter Solutions Monarch - 433TSPW2K is a key chain style
mini transmitter operating at 433.92 MHz. It has been designed for use
with programmable telephone entry, security, and access control
systems operating with a MHz frequency receiver.
codes .
433.92
The code sent by the transmitter includes a 16 bit security code which
allows up to 65,536 number combinations and 8 bits of facility code
which allows up to 256 facility
CONTENTS
1A - General information
1B - Technical specifications
1C - Main components
1 - TRANSMITTER OVERVIEW
2 - NUMBERING
3 - PROGRAMMING
4 - OPERATION
5 - BATTERY ACCESS
1B - Technical specifications
Operating frequency 433.92 MHz
Number of keys: 2
Battery life: 18 24 months
Number combinations :
Operating temperature: -20°F÷+131°F (-20°C
Overall dimensions: 2.4”x1.4”x0.63” (61x36x16 mm)
Weight: 1 oz. (20 gr.)
Battery : 2 x 3V lithium batteries CR2016
÷
65,536
Facility Codes : 256
÷+55°C)
The Transmitter Solutions - 433R receiver which operates with this
transmitter has a Wiegand 30 bit format output, which will operate any
type of access control system equipped to accept a 30 bit Wiegand
input. The CR 2016 lithium batteries have a shelf life of about 6 months.
Part 15 of FCC Regulations andThe product fully complies with the
European Directives 99/5/CE, 89/336/CEE, 73/23/CEE.
1C - Main components
Push-button B
Red
LED
Key
holder
ring
Battery
door
Push-button A
6 - TROUBLESHOOTING
Dark Red & White Case
Transmitter
Solutions
Thank you for choosing a Transmitter Solutions product .
Please read this manual carefully before using the product.
Made in Italy. Copyright Transmitter Solutions© 2006 by
Manual
MONARCH 433TSPW2K
All manuals and user guides at all-guides.com
all-guides.com
2 - NUMBERING
6 - TROUBLESHOOTING
PROBLEM SOLUTION
The operating range is reduced
Check to verify the
transmitter is programmed
into your system
Replace the transmitter
batteries
To access the battery turn the battery door
. Place the 2 lithium CR2016 batteries
into their holder making sure they make contact
with the internal ring and with the positive (+) side
of the battery facing the back of the transmitter.
clockwise
NOTE: Please dispose of the batteries properly
according to local laws and regulations.
Test proper battery installation by verifying that
the red LED illuminates when either button is
pushed.
5 - BATTERY ACCESS
3 - PROGRAMMING
Each transmitter is manufactured and sold with a different factory set
sequence number and facility code.
The transmitter facility code and sequence number must be
programmed into your system memory. Your own installer or reseller will
provide you the necessary instructions for your system.
Replace the transmitter
batteries
Transmitter Solutions - Type : SETR2641AM2
FCC ID : PWJT433
This device complies with FCC Rules
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) this device must accept interference received, including
interference that may cause undesired operation.
Part. 15 of the
The system does not receiver the
transmitter signal.
The transmitter LED is ON
The system does not receiver the
transmitter signal.
The transmitter LED will not light
4 - OPERATION
a. Firmly depress either button until the small red LED illuminates.
b. After the LED has illuminated, release the button. If the device you are
attempting to activate does not respond, repeat steps a. and b. or
consult section 6 (Troubleshooting) of this manual.
Back of
transmitter
TRANSMITTER SOLUTIONS
2505 Chandler Avenue, Suite, 1
Las Vegas, NV 89120 -
(866) 975-0101 - (866) 975-0404 Fax
[email protected]
The warranty period of 433 transmitters is 24 months,
beginning from the manufacturing date of the transmitter. During this period, if the
product does operate correctly, due to a defective component, the product will be
repaired or replaced at the sole discretion of .
The warranty does not extend to the transmitter case which can be damaged by
conditions outside the control of or to battery life.
Transmitter Solutions
Transmitter Solutions
Transmitter Solutions
WARRANTY
Notice
Any changes or modification to equipment not expressly
approved by could void the manufacturer’s warranty.
Transmitter Solutions
Transmitter Solutions
IS-TMW433CCUK Rev. 1 del 22.05.2006
All manuals and user guides at all-guides.com