Switches A4 and A5 set the
running current to 70%, 80%,
90% or 100% of the motor’s
rated maximum current.
Switches A6 - A8 specify the drive’s micro-
step resolution
200
200 with microstep emulation (smooth)
400
400 with microstep emulation (smooth)
2000
5000
12800
20000
NOTE: DIP switch setting changes will only take effect at power up. If changes to the DIP switches
are made while power is applied, cycle power off then on for the new settings to take effect.
Motor selection is done with the DIP switch block on the
narrow face of the drive. These switches are referred to
as B1 - B3 in the STR2 Hardware Manual.
MMOOTTOORR
HT08-020/021
MMOOTTOORR
HT17-271
HT17-275
HT23-595
HT23-598
HT23-601
Switch A3 sets
the idle current to
either 50% or 90%
of the selected
running current.
3
50% 90%
The STR has a built in Self Test function. If switch A1 is
moved to the ON position the drive will automatically rotate
the motor back and forth, two turns in each direction. This
feature can be used to confirm that the motor is correctly
wired, selected and otherwise operational.
A full user manual for the STR is available for download
from our web site. This contains full details on setup,
wiring and installation.
www.applied-motion.com/support
SSeettttiinngg uupp tthhee DDrriivvee
SStteepp 33 -- SSeelleeccttiinngg tthhee mmoottoorr SStteepp 44 -- SSeelleeccttiinngg ccuurrrreenntt
SStteepp 55 -- LLooaadd iinneerrttiiaa SStteepp 66 -- SStteepp rreessoolluuttiioonn
SStteepp 77 -- SSeellff tteesstt SStteepp 88 -- UUsseerr mmaannuuaall
If you have any questions or comments, please call
Applied Motion Products Customer Support:
(800) 525-1609, or visit us online:
www.applied-motion.com.
18645 Madrone Pkwy.
Morgan Hill, CA 95037
Tel: 800-525-1609
www.applied-motion.com
Switch B4 chooses between two
load inertia ratio ranges.
This information is used in the
anti-resonance configuration.
5-
10X
0-
4X
920-0113 RevD