Motif Medical Twist Quick start guide

Motif Twist
Operational
Manual

2
Be sure to register your breast pump upon receiving it:
motifmedical.com/warranty-registration/
1. Introduction
Meet The Twist
Small, easy-to-use, and cost eective, the Twist
is Motif’s aordable portable pump — perfect
for the mom on-the-go. Weighing less than half
a pound, the Motif Twist easily and conveniently
fits into your bag so you can be ready to pump
whenever and however you need.
All Motif Medical® products purchased from authorized retailers come
with a manufacturer’s warranty stating that product will be free from
defects in workmanship and materials; for 2-years on double-electric
breast pumps, for 1-year on internal batteries, and for 90-days on breast
pump parts.

3MOTIF MEDICAL® | THE TWIST BREAST PUMP | OPERATION MANUAL

1. Introduction 2
2. Highlights 7
3. Intended Use (Indications of Use) 8
4. Symbols 9
5. Safety 10
5.1 Prohibitions, Warnings, and Cautions 10
6. Parts 13
6.1 What’s Included 13
6.2 Features 15
6.3 Settings and Modes 16
7. Sterilization and Cleaning 17
8. Operating Your Breast Pump 20
8.1 Breast Shield Sizing 20
8.2 Assembling The Twist Pump 23
8.3 How to Use The Dual Pump 25
8.4 Turning On/Off The Twist Pump 26
Index

9. Using Your Motif Twist Pump 27
9.1 Pumping Guide 27
9.2 Getting Ready to Pump 28
9.3 Aligning the Breast Shield 29
9.4 Expressing Your Milk 30
9.5 After Pumping 31
9.6 Storing Breast Milk 32
10. Troubleshooting 34
10.1 Troubleshooting 34
10.2 Disposal 36
10.3 When to Replace Parts 37
11. Warranty 39

6

7MOTIF MEDICAL® | THE TWIST BREAST PUMP | OPERATION MANUAL
2. Highlights
The Motif Twist Double Electric Breast Pump
utilizes a vacuum to express breast milk.
Quiet Motor
No loud hum. Great for discreet
pumping.
Pump How You Want
Single or double pumping option
and adjustable suction pattern
designed for maximum let-down.
Closed System
Backflow protection keeps
the motor and tubing clean,
preventing contamination.
Pump On-the-Go
Dual power options. Use it
stationary or on battery power.
Super Lightweight Design
Weighs less than 1/2 a pound for
perfect portability.

8
3. Intended Use (Indications of Use)
The Motif Twist Double Electric Breast Pump is intended for use by
lactating women to express and collect breast milk. The Twist can be
used as a single or double pump.
This appliance is not intended for use by persons (including children)
with reduced physical, sensory, or mental capabilities unless they are
under supervision or instruction by persons responsible for their safety.
Please read this document completely and follow the instructions
exactly. To prevent personal injury and material damage, please
observe the warning and safety information provided in this document.
Caution: To avoid minor injury
• Sharing a breast pump can cause health hazards and void manufacturers
warranty.

9MOTIF MEDICAL® | THE TWIST BREAST PUMP | OPERATION MANUAL
4. Symbols
Warning: Potentially dangerous situation that could result in serious injury.
Caution: A possibly dangerous situation that could result in slight bodily injury.
Notice: Useful information or information you need to know when using this product.
Manufacturer
Date of manufacturer
Serial number
Refer to instruction manual
Type BF applied part
Class II equipment
Keep dry
IP22 Degree of protection against harmful ingress of water or particulate matter.
This product should not be mixed with other commercial waste for disposal

10
5. Safety
5.1 Prohibition, Warnings, and Cautions
Prohibition: To prevent voiding of warranty
• Do not modify this equipment without authorization of the manufacturer.
• Do not disassemble or modify the product. The device has no user-
serviceable parts.
Warning: To avoid fire, electrocution, or serious burns
• Do not leave the product unattended when plugged into an electrical outlet.
• Close supervision is necessary when this product is used near children or
persons with disabilities.
• Place product out of reach of children.
• Use the product only for its intended use as described in this manual. Do not
use attachments not recommended by the manufacturer.
• Never operate this product if it has a damaged cord or plug if it is not working
properly, or if it has been dropped or damaged, or dropped into water.
• Keep cord away from heated surface.
• Never use while sleeping or when drowsy.
• Never drop or insert any object into any opening or tubing.
• Do not use outdoors, or operate where aerosol (spray) products are being
used where oxygen is being administered.
• Always inspect power adapter wires prior to use for damage or exposed wire.
If damage is found, immediately discontinue use of power adapter and call
Motif Medical® Customer Service.
• The Motif Medical® Twist should not be positioned so that it is difficult to
operate the adapter.

11MOTIF MEDICAL® | THE TWIST BREAST PUMP | OPERATION MANUAL
Warning: To reduce the risk of electrocution
• Always unplug immediately after use.
• Do not use while bathing.
• Do not place or store product where it can fall or be pulled into a tub or sink.
• Do not place or drop into water or other liquid.
• Do not reach for a product if it has fallen into water. Immediately unplug from
electrical outlet.
Warning: To avoid health risk and reduce the risk of injury
• If you are a mother who is infected with Hepatitis B, Hepatitis C or Human
Immunodeficiency Virus (HIV) pumping breast milk will not reduce or remove
the risk of transmitting the virus to your baby through your breast milk.
• Before each use visually inspect the individual components for cracks, chips,
tears, discoloration or deterioration. In the event that damage to the device is
observed, please discontinue use until the parts have been replaced.
• This product is the intended for use by a single user only and should not be
shared between users.
• Do not drive while pumping.
• Never use while pregnant, as pumping can induce labor.
• Clean and sanitize all parts that come in contact with your breast and breast
milk prior to first use.
• Wash all parts that come in contact with your breast and breast milk after every
use.
• Do not continue pumping for more than 2 consecutive pumping session if no
results are achieved.
• Do not thaw frozen breast milk in a microwave or in a pan of boiling water.
• If tubing becomes moldy, discontinue use and replace with new tubing.
• If breast milk backup occurs you must clean tubing before your next pumping
session.

12
Caution: To avoid minor injury
• Do not wrap cord around adapter body.
• Use only the power adapter that comes with the powered breast pump.
• Pump only with the breast pump in an upright position.
• Do not shorten tubing.
• Make sure the voltage of the power adapter is compatible with the power
source.
• Plug the power adapter into the breast pump first and then into the wall
socket.
• Do not use antibacterial or abrasive cleaners/detergents when cleaning the
breast pump or breast pump parts.
• Never put the breast pump motor in water or sterilizer as you can cause
permanent damage to the breast pump.
• Do not attempt to remove the breast shield from your breast while pumping.
Turn the breast pump off and break the seal between your breast and breast
shield with your finger, then remove breast shield from your breast.
• If pumping is uncomfortable or causing pain, turn the unit off, break the seal
between the breast and breast shield with your finger, and remove the breast
shield from your breast.
• Plastic bottles and component parts become brittle when frozen and may
break when dropped.
• Bottles and component parts may become damaged if mishandled, e.g.
dropped, over- tightened or knocked over.
• Take appropriate care in handling bottles and components.
• Do not use the breast milk if bottles or components become damaged.
5. SAFETY

13MOTIF MEDICAL® | THE TWIST BREAST PUMP | OPERATION MANUAL
6. Parts
6.1 What’s Included
While unpacking the box, make sure all of the following
components are enclosed.
1Powered Breast Pump,
Motif Medical® Twist
2Tubing (2)
3Tubing Connector (4)
4Diaphragm Top (2)
5Diaphragm (2)
624mm, 28mm, & 32mm Breast
Shields (2 each)
7Breast Shield Connector (2)
8Bottle Ring (2)
9Valve (2)
10 Membrane (2)
11 Storage Container (2)
12 Storage Container Base (2)
13 Bottle Cap (2)
14 Bottle Nipple (2)
15 Sealing Disc (2)
16 Screw Cover (2)
17 Power Adapter
-140 mL Milk Collection Kits (2)
4
13
14
15
5
7
9
10
11
12
1
2
3
6
17
8
16

14
6. PARTS
Additional accessories and parts available for the Twist breast pump:
• Full resupply kit with replacement parts
• Individual parts
Find replacement parts and additional supplies for the Twist at:
motifmedical.com/replacement-supplies/

15MOTIF MEDICAL® | THE TWIST BREAST PUMP | OPERATION MANUAL
6.2 Features
30 Min. Timer
(10 Blue LED light timer
3 minutes per)
Max Power
(Maximum suction power)
White Light
(White light shows
suction power)
Modes
(Dash line: Massage)
(Solid line: Expression)
Min. Power
(Minimum Suction Power)
On/Off
(Twist to turn On/Off)
MAX
MIN

16
6.3 Settings and Modes
The cycle level refers to the number of full pumping motions the device
will complete per minute; this is measure in Cycles Per Minute (CPM).
The Cycles Per Minute change as the suction strength is increased.
Suction Settings
The suction level on your breast pump refers to the suction strength;
this is measured in mm-Hg. When you are using your Motif Medical®
Twist, you will usually find that expressing is most effective on the
highest suction level that you are comfortable with.
However, it’s important not to set section level so high that it makes
you uncomfortable, as the resulting pain will hinder your milk flow.
Massage Modes
Suction pattern with fast cycles and low vacuum to help with Letdown and
to start the flow of milk. The Massage Mode on the Motif Twist is indicated
by the Dashed Line.
Expression Modes
Suction pattern with slower cycles and higher vacuum to express milk
gently and efficiently. The Expression Mode on the Motif Twist is indicated
by the Solid Line.
6. PARTS

17MOTIF MEDICAL® | THE TWIST BREAST PUMP | OPERATION MANUAL
7. Sterilization and Cleaning
Before initial use sterilize each part of the:
• Diaphragms
• Valves
• Breast Shields
• Bottles
• Bottle Caps
• Nipples
*Do not sterilize or wash the tubing.
Repeat sterilization of other listed parts once daily after pump use.
Sterilization Instructions
1. If parts have been used previously, following cleaning
instructions first.
2. Place your breast pump parts in a pot and cover them with
water.
3. Bring water to a boil and let boil for five minutes.
4. Remove parts with clean tongs.
5. Place pump parts on a clean paper towel or dish towel and
allow to air dry completely.
Parts can also be sterilized in a steam sterilizer or microwave
sterilization bag to sterilize breast pump parts quickly and
efficiently.
Be sure not to place tubing into the Sterilizer Bags in attempt
to clean the tubing.

18
7. STERILIZATION AND CLEANING
Cleaning Instructions
1. Thoroughly wash your hands with warm soap and water.
2. Disassemble each breast pump part that came into
contact with breast milk. This includes the valves, bottles,
breast shields, and nipples. *Do not clean the tubing or
diaphragms. Diaphragms do not need to be cleaned
unless milk or moisture develops in them. If moisture or
milk becomes present in the tubing, replace it as soon as
possible. Do wash and hang it to dry if you need to use it
again before replacing. Assure the tubing is dry before use.
Moisture in the tubing could be pulled into the pump and
damage the motor.
3. Rinse each part with cool water to remove milk residue.
4. Options for washing pump parts:
• Separately wash each part in the sink with a soft brush and
soap. (Be sure to use a new brush or washcloth exclusively
for breast pump parts.)
• Soak each part in warm, soapy water for 5 minutes and
then thoroughly rinse them.
5. Dry each part with a clean towel or allow to fully air dry on a
sanitary surface, such as a clean paper towel or clean dish
towel. Do not pat dry.
6. Wipe the outside of your breast pump with a dry, clean towel.
*Do not wash the outside of your breast pump with water or
get your breast pump wet when cleaning it.
It is not recommended to wash and dry Motif Breast Pump
parts in the dishwasher. There is no standard temperature for
dishwashers and some may warp parts. Parts damaged in the
dishwasher are not covered under warranty.

19MOTIF MEDICAL® | THE TWIST BREAST PUMP | OPERATION MANUAL
After Every Use
1. Thoroughly wash your hands before handling each breast
pump component.
2. Disassemble each part that comes into contact with breast
milk including the valve, bottle, bottle nipple, breast shield,
bottle disk, and bottle cover.
3. Rinse each part in cool water to remove milk residue.
4. Options for washing individual parts:
• Separately wash each part with a soft brush or a clean
dishcloth.
• Soak each part in warm soapy water for 5 minutes then
thoroughly rinse them.
5. Dry each part with a clean towel and/or allow them to
completely air dry on a sanitary surface.
6. Wipe the main body with a dry, clean towel after each use.
*Never use water to wash the outside of your breast pump.
7. Store parts after they completely dry in a clean bag or
container. *Do not store any damp parts.

20
8. Operating Your Breast Pump
8.1 Breast Shield Sizing
Understanding size
Pumping should not hurt. This guide is a starting point to help determine
your optimal breast shield size based on your nipple diameter.
How To Find The Right Size Breast Shield For You
Step 1
Using a ruler or measuring
tape measure the diameter
of your nipple at the base
(across middle) in millimeters
(mm).
NIPPLE BASE
MEASURE
AREOLA
NIPPLE
*1 cm = 10 mm
Do not include the areola.
Step 2
Take your measurement and
add 4mm to determine your
breast shield size.
Example: If your nipple
size measures 26 mm in
diameter, the recommended
breast shield size is 30 mm.
Table of contents
Other Motif Medical Medical Equipment manuals
Popular Medical Equipment manuals by other brands

Drive Medical
Drive Medical 13003 Assembling instructions

Nonin
Nonin 8500 Troubleshooting

Braun
Braun Aesculap activ C Instructions for use/Technical description

HARVARD
HARVARD 33 user manual

Smart Caregiver
Smart Caregiver 433-CMU-40 quick start guide

PhotoniCare
PhotoniCare TOMi Scope Quick Start Pocket Guide