Motorline professional M1805-X Instruction Manual

V1.0
REV. 10/2021
M1805-XM1805-X EN
USER/INSTALLER MANUAL

A B
2B
5
7
8
9
10A
11
12
13A
13B
15
6
10B
14
ENEN
. CONTENT
INDEX
. SAFETY INSTRUCTIONS
ATTENTION:
COMPONENTS CONNECTION
CONNECTION OF 2 SINGULAR DOORS WITH INTERLOCK
DOOR WITH 2 LEAVES
. SAFETY INSTRUCTIONS
. CONNECTION SCHEMES
TECHNICAL CHARACTERISTICS
. THE AUTOMATION
INSTALLATION MEASURES | OPENING DIRECTION
. PREINSTALLATION
INSTALLATION PROCESS
. INSTALLATION
TECHNICAL CHARACTERISTICS
PROGRAMMING
. THE CONTROL BOARD
INSTRUCTIONS FOR FINAL CONSUMERS / SPECIALIZED INSTALLERS
. TROUBLESHOOTING
RADARS AND PROGRAM SELECTOR CONNECTION
WIDTH/WEIGHT RATIO
DIGITAL DISPLAY AND FUNCTIONS
This product is certified in accordance with European
Community (EC) safety standards.
This product complies with Directive 2011/65/EU of the
European Parliament and of the Council, of 8 June 2011, on
the restriction of the use of certain hazardous substances
in electrical and electronic equipment and with Delegated
Directive (EU) 2015/863 from Commission.
(Applicable in countries with recycling systems).
This marking on the product or literature indicates that the
product and electronic accessories (eg. Charger, USB cable,
electronic material, controls, etc.) should not be disposed
of as other household waste at the end of its useful life. To
avoid possible harm to the environment or human health
resulting from the uncontrolled disposal of waste, separate
these items from other types of waste and recycle them
responsibly to promote the sustainable reuse of material
resources. Home users should contact the dealer where
they purchased this product or the National Environment
Agency for details on where and how they can take these
items for environmentally safe recycling. Business users
should contact their vendor and check the terms and
conditions of the purchase agreement. This product and
its electronic accessories should not be mixed with other
commercial waste.
This marking indicates that the product and electronic
accessories (eg. charger, USB cable, electronic material,
controls, etc.) are susceptible to electric shock by direct or
indirect contact with electricity. Be cautious when handling
theproductandobserveallsafetyproceduresinthismanual.
CONNECTION OF PUSH LOCK WITH MDL1805 MODULE

EN
. AVISOS DE SEGURANÇA. AVISOS DE SEGURANÇA
GENERAL WARNINGS
•This manual contains very important safety and usage information.
very important. Read all instructions carefully before beginning the
installation/usage procedures and keep this manual in a safe place
that it can be consulted whenever necessary.
•This product is intended for use only as described in this manual. Any
other enforcement or operation that is not mentioned is expressly
prohibited, as it may damage the product and put people at risk
causing serious injuries.
•Thismanualisintendedfirstly forspecialized technicians, and does not
invalidate the user’s responsibility to read the “User Norms” section in
order to ensure the correct functioning of the product.
•The installation and repair of this product may be done by qualified
and specialized technicians, to assure every procedure are carried
out in accordance with applicable rules and norms. Nonprofessional
and inexperienced users are expressly prohibited of taking any action,
unless explicitly requested by specialized technicians to do so.
•Installations must be frequently inspected for unbalance and the
wear signals of the cables, springs, hinges, wheels, supports and other
mechanical assembly parts.
•Do not use the product if it is necessary repair or adjustment is
required.
•When performing maintenance, cleaning and replacement of parts,
the product must be disconnected from power supply. Also including
any operation that requires opening the product cover.
•The use, cleaning and maintenance of this product may be carried
out by any persons aged eight years old and over and persons whose
physical,sensorialormentalcapacitiesarelower,orbypersonswithout
any knowledge of the product, provided that these are supervision
and instructions given by persons with experienced in terms of usage
of the product in a safe manner and who understands the risks and
dangers involved.
•Children shouldn’t play with the product or opening devices to avoid
. SAFETY INSTRUCTIONS
the motorized door or gate from being triggered involuntarily.
WARNINGS FOR TECHNICIANS
•Before beginning the installation procedures, make sure that you have
all the devices and materials necessary to complete the installation
of the product.
•You should note your Protection Index (IP) and operating temperature
to ensure that is suitable for the installation site.
•Provide the manual of the product to the user and let them know how
to handle it in an emergency.
•If the automatism is installed on a gate with a pedestrian door, a door
locking mechanism must be installed while the gate is in motion.
•Do not install the product “upside down” or supported by elements do
not support its weight. If necessary, add brackets at strategic points
to ensure the safety of the automatism.
•Do not install the product in explosive site.
•Safety devices must protect the possible crushing, cutting, transport
and danger areas of the motorized door or gate.
•Verify that the elements to be automated (gates, door, windows,
blinds, etc.) are in perfect function, aligned and level. Also verify if the
necessary mechanical stops are in the appropriate places.
•The centralmust beinstalledon asafe placeof any fluid (rain, moisture,
etc.), dust and pests.
•You must route the various electrical cables through protective tubes,
to protect them against mechanical exertions, essentially on the
power supply cable. Please note that all the cables must enter the
central from the bottom.
•If the automatism is to be installed at a height of more than 2,5m from
the ground or other level of access, the minimum safety and health
requirements for the use of work equipment workers at the work of
Directive 2009/104/CE of European Parliament and of the Council of 16
September 2009.
•Attach the permanent label for the manual release as close as possible

EN
to the release mechanism.
•Disconnect means, such as a switch or circuit breaker on the electrical
panel, must be provided on the product’s fixed power supply leads in
accordance with the installation rules.
•If the product to be installed requires power supply of 230Vac or
110Vac, ensure that connection is to an electrical panel with ground
connection.
•The product is only powered by low voltage satefy with central (only
at 24V motors)
WARNINGS FOR USERS
•Keep this manual in a safe place to be consulted whenever necessary.
•If the product has contact with fluids without being prepared, it must
immediately disconnect from the power supply to avoid short circuits,
and consult a specialized technician.
•Ensure that technician has provided you the product manual and
informed you how to handle the product in an emergency.
•Ifthesystemrequiresanyrepairormodification,unlocktheautomatism,
turn off the power and do not use it until all safety conditions have
been met.
•In the event of tripping of circuits breakers of fuse failure, locate
the malfunction and solve it before resetting the circuit breaker or
replacing the fuse. If the malfunction is not repairable by consult this
manual, contact a technician.
•Keep the operation area of the motorized gate free while the gate in in
motion, and do not create strength to the gate movement.
•Do not perform any operation on mechanical elements or hinges if the
product is in motion.
RESPONSABILITY
•Supplier disclaims any liability if:
•Product failure or deformation result from improper installation
use or maintenance!
•Safety norms are not followed in the installation, use and
maintenance of the product.
•Instructions in this manual are not followed.
•Damaged is caused by unauthorized modifications
•In these cases, the warranty is voided.
. SAFETY INSTRUCTIONS
SYMBOLS LEGEND:
• Important safety notices
• Useful information
• Programming information
• Potentiometer information
• Connectors information
• Buttons information

+24V
0V
NO
COM
12-24V
AC/DC
NO
COM
12-24V
AC/DC
IN-LOC OU-LOC GND
24+
RAPM-PRO
EN
. CONNECTION SCHEMES
COMPONENTS CONNECTION
º M Radar
Control board
Magnetic lock
Electric lock
MDL module
Battery V
Automatism Radar
V
V
The electro lock current can not exceed 600mA.
All connections should be made with the power supply disconnected.
º M Radar

12
13
14
15
16
17
18
19
20
21
22
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
1
2
3
4
5
6
7
8
9
10
11
EN
. CONNECTION SCHEMES
RADARS AND PROGRAM SELECTOR CONNECTION
PROGRAM
SELECTOR
EXTERNAL
Radar M
INTERNAL
Radar M
red
white
purple
orange
green
green
white
white
yellow
yellow
brown
brown
green
black
Control board
Control board

12
13
14
15
16
17
18
19
20
21
22
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
1
2
3
4
5
6
7
8
9
10
11
EN
. CONNECTION SCHEMES
CONNECTION OF SINGULAR DOORS WITH INTERLOCK
Operation: When using singular doors with interlocking, connected to each other,
you should be aware these connections.
Only when one of the doors is closed, the other can open. When using this function,
if one of the doors is disconnected from the electric current, the other will not open.
Control board of the st door
st door
is closed
nd door
started
opening
Control board of the nd door
All connections should be made with the power off.

12
13
14
15
16
17
18
19
20
21
22
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
1
2
3
4
5
6
7
8
9
10
11
EN
. CONNECTION SCHEMES
DOOR WITH LEAVES
When using a kit of two sheets:
1 - LED of both switches must be ON.
2 - When the door input is set to leaf , LED must be ON and LED
of the opposite panel must be OFF.
3 - Leaf will open first than leaf . When closing, the maneuver is
carried out simultaneously by the two leaves.
4 - The -leaf and interlocking-leaf systems cannot be used,
otherwise the two automatic doors will not work correctly.
Combination to turn on LED's
To turn on/off any of the LEDs, you must be pressing the
combinations while connecting the control board to the power
supply:
LED 1 - Button with Button -
LED 2 - Button SET with Button
Operation: When using a door with two leaves, you should note these connections.
This function will allow the two sheets work in a coordinated manner.
All connections must be made with the power supply disconnected.
In this function, if the leaf nº2 encounters an obstacle during closure, the micro
will give opening order to the 2 leaves automatically, to ensure that the closure
will be done correctly.
Leaf nº
Leaf nº
Control board Control board
DOOR 1 LED 1 ON- Master
DOOR 1 LED 2 ON - 2 doors ON
DOOR 2 LED 1 OFF - Slave
DOOR 2 LED 2 ON - 2 doors ON

IN-LOC OU-LOC GND 24+
OUT
GND
GND
V
EN
CONNECTION OF PUSH LOCK WITH MDL MODULE
Operation: Whenever an impulse lock is used, the MDL module must be placed.
With this module, whenever the automation receives an opening order, a signal is
sent to the electrolock for ms to unlock and allow opening.
. CONNECTION SCHEMES

A B
0
20
40
60
80
100
120
600 700 800 900 1000 1100 1200
ENEN
TECHNICAL CHARACTERISTICS
The M-X is an automation with anodized aluminum chassis, developed to use in
pedestrian
doors up to kg.
• The control board is microprocessor controlled and does self programming. Users only
need to select the speeds and the pause time.
• The automation has obstacle detection function and self-protection for overheating,
overvoltage and overcurrent.
• Power Supply 230Vac 50Hz
• Potency 65W/100W
• Door Type Opening to the right or left
Internal or external opening
• Opening angle 90°
• Opening speed (90°) Adjustable
• Closing speed (90°) Adjustable
• Pause time in opening 0.5 - 10 seconds
• Manual strength <30N
• Consumption 65W/100W
• Operating temperature -30°Ϲ to +50°Ϲ
• Door's maximum weight 120kg
• Accessories output 500mA
• Eletric lock output 600mA
. THE AUTOMATION
Door maximum
weight: kg
WIDTH/WEIGHT RATIO
Door weight (kg)
Door width (mm)
. THE AUTOMATION
TECHNICAL CHARACTERISTICS
Motor
* Arm
* Arm for interior opening
* Arm for external opening
Fixing
screws Profile
cover
Fixing
screws
Profile for fixing
to the door
Dimensions in mm

x
y
x
y
EN
. PRE-INSTALLATION
INSTALLATION MEASURES | OPENING DIRECTION
Interior opening
Exterior opening
INTERIOR OPENING
Quotas Y Quotas X
230 240 250 260 270 280 290 300 310 320 330
-40 109° 100° 93°
-30 111° 102° 95°
-20 114° 105° 97° 91°
-10 116° 107° 100° 93°
0120° 110° 102° 96° 90°
10 120° 112° 104° 97° 92°
20 120° 114° 106° 100° 94°
30 120° 116° 108° 101° 96° 91°
40 120° 118° 110° 103° 98° 93°
50 120° 120° 112° 105° 99° 94° 90°
60 120° 120° 114° 107° 101° 96° 92°
70 120° 120° 115° 109° 103° 98° 93°
80 120° 120° 120° 110° 104° 99° 95° 90°
90 120° 120° 120° 112° 106° 101° 96° 92°
100 120° 120° 120° 113° 107° 102° 97° 93°
110 120° 120° 120° 114° 109° 103° 99° 94° 91°
120 120° 120° 120° 115° 110° 104° 100° 96° 92°
130 120° 120° 120° 116° 111° 106° 101° 97° 93°
140 120° 120° 120° 120° 112° 106° 102° 98° 94° 90°
150 120° 120° 120° 120° 112° 107° 103° 98° 95° 91°
EXTERIOR OPENING
Quotas Y Quotas X
180 190 200 210 220 230 240 250 280 290 300
110 120° 120° 120° 114° 105° 97° 91°
120 120° 120° 120° 110° 101° 94°
130 120° 120° 117° 107° 98° 91°
140 120° 120° 113° 103° 95°
150 120° 120° 109° 100° 92°
160 120° 117° 105° 96°
170 120° 113° 102° 93°
180 120° 109° 99° 90°
190 118° 105° 95°
200 114° 102° 92°
210 111° 99° 90°
220 108° 96°
230 105° 94°
240 103° 91°
250 101°
Maximum opening angles for the several combinations of allowed dimensions: Maximum opening angles for the several combinations of allowed dimensions:

2
10
3
9
8
8
10
76
4
5
2
10
3
8
6
4
5
2
1
EN
. INSTALLATION
INSTALLATION PROCESS
•
INTERIOR OPENING
•
EXTERIOR OPENING
Remove the front cover of the automation, with the help of
two screwdrivers.
Position the fixing body on the wall and make the markings.
Drill holes in the marked places.
Apply bushings in the holes made.
Direct the motor body and apply the screws, tightening
completely.
Fit the arm onto the shaft and tighten the corresponding
bolt.
Insert the door guide into the existing square in the arm.
(Only for INTERIOR OPENING)
Fix the guide/plate to the door.
Apply the side covers to the guide.
(Only for INTERIOR OPENING)
Apply the motor cover.
1
2
3
4
5
6
7
8
9
10

A B
60mm
167mm
47mm
ENEN
. THE CONTROL BOARD
TECHNICAL CHARACTERISTICS
. THE CONTROL BOARD
TECHNICAL CHARACTERISTICS
Conetores
1 • +24V battery power input
2 • Magnetic lock or impulse lock module
3 • +12V auxiliary power supply
4 • GND
5 • +24V component power supply
6 • GND
7 • Opening safety photocells (NO)
8 • 2nd radar input
9 • Two door interlock entry - Interlock
10 • Double Door Lock Output - Interlock
11 • Backup Power Function Selection
12 • Double common - for 2-sheet system
13 • Dual output - for 2-sheet system
14 • Double entry - for 2-sheet system
15 • 1st radar entry
16 • Safety photocells in the closing (NO)
17 • FUTURE USE
18 • FUTURE USE
19 • FUTURE USE
20 • FUTURE USE
21 • FUTURE USE
22 • FUTURE USE
PROGRAMMING
Turn on the electrical current. The door will work as follows:
Opensslowly→ Closes (tomemorizeposition)andstaysinnormaloperationafterthiscycleiscompleted.
•Before connecting the automation to the current, the stop must be installed, so that the
control board can recognize the course.
-Decrease button
+Increase button
SET Select function button
TEST Test button (START)
Dippers
ON OFF
ALeft opening Right opening
B
Second sensor switch
sensor and secondary induction
selection switch.
With this option, an order occurs on radar 1
and radar 2 at the same time.
Second sensor switch disabled
CDisable lock Activates 2/4 output for lock
LED1 For 2-leaf system - ON sets sheet 1
LED Signal light - sensor signal indicator
LED2 Signals 2-leaf system active
To activate LED and LED functions:
01 • Turn off power supply
02 • Press "+" and "-" simultaneously and turn on the power
03 • LED 1 will light up and the door starts recognizing
01 • Turn off power
02 • Press "+" and "SET" simultaneously and turn on power
03 • LED 2 will light up and door recognition starts

A ENEN
. THE CONTROL BOARD
DIGITAL DISPLAY AND FUNCTIONS
Opening speed ( to )
Deceleration distance on door opening ( to )
Door slowdown speed ( to )
Closing speed ( to )
Closing deceleration distance ( to )
Closed automation force ( to )
Pause time ( to - corresponds to seconds)
Start force ( to )
Selection of the functionIncrease button
Decrement button Test button (START)

EN
. TROUBLESHOOTING
INSTRUCTIONS FOR FINAL CONSUMERS / SPECIALIZED INSTALLERS
Anomaly Procedure Behavior Procedure II Find source of the problem
• Door/Motor
doesn't work • Make sure you have
a V power supply
connected to the control
board and if it is working
properly.
• Still not working • Consult a qualified
MOTORLINE technician.
• Door/Motor
doesn’t move
but makes
noise
• Turn off the V
power supply and move
the door manually
to check if there are
mechanical problems.
• Found problems? • Consult an experienced
door expert.
• The door moves easily? • Consult a qualified
MOTORLINE technician.
• Door/Motor opens
but doesn't close •Turn off the V
power supply and move
the door manually to the
closed position. Turn off
the building eletric board
for seconds and then
turn on.
• The door opened but
did not closed. 1• Check if there is any
obstacle in front of the
photocells;
• Check if any of the
door control devices
(key selector and push
button) are locked and
are sending permanent
signal to the control
board;
3• Consult a qualified
MOTORLINE technician.
• Door/Motor
doesn’t
make
complete
route
• Turn off the power
supply and move the
door manually to check
if there are mechanical
problems.
• Found problems? • Consult an experienced
door expert.
• The door moves easily? • Consult a qualified
MOTORLINE technician.
1 • Open the control board and
check if it has a V power
supply;
2• Check the control board input
A) SAFETY SYSTEMS
(Opening security systems NO;
Closing security systems NO):
1• Disconnect everything from
the Security input.
If the automation starts to work
normally, analyze which device is
the problem.
1• Make a new programming
course in control board
attributing the necessary times to
open and close with appropriate
force.
Check all axes and motion
systems associated with the
door and automatism (shafts,
Check all axes and movement
systems associated with the
If the door works, the problem is
in the motor. Remove it and send
it to the MOTORLINE technical
fuses (switch);
• If the motor does not work,
remove it and send it to the
MOTORLINE technical services
2• Replace the defective device
with a functional one. Check if
the automation works correctly
again. If not, repeat step to
discover another malfunctioning
device.
2• If that does not work, remove
the control board and send it to
the MOTORLINE technical services
for diagnosis.
NOTE: The control board strength
hinges, etc.) to find out what the
problem is.
door and automation (wheels,
hinges, etc.) to find out what the
services for diagnosis;
for diagnosis.
must be sufficient to open and
close the door without stopping,
but a person must be able to stop
it with small effort. In case of
safety systems failure, the door
will never cause physical damage
problem is.
to the obstacles (vehicles,
people, etc.).
Table of contents
Popular Door Lock manuals by other brands

Kaba
Kaba PowerLever 15 Series operating instructions

LSDA
LSDA 220 Series quick start guide

SDC
SDC PBD2090A installation instructions

Baldwin
Baldwin 800.566.1986 quick start guide

TownSteel
TownSteel Prodigy SmartLock 4000 Series Programming guide

Assa Abloy
Assa Abloy Corbin Russwin ED7800 Series installation instructions