Motorline MLS4 Instruction Manual

V1.0
REV. 05/2018
MLS4 EN
USER/INSTALLER MANUAL

A B
ENEN
1B
2B
3A
5A
5A
6B
5B
6B
6A
6B
7A
STANDARDS TO FOLLOW
DESCRIPTION
DEVICE INSTALLATION
FACTORY RESET AND SET MANAGEMENT CARD
ADMIN SETTING ON KEYPAD
USER OPEN DOOR OPERATION
PRODUCT INSTALLATION
REMOVE ALARM OPERATION
ADMIN CARD OPERATION
SOUND AND LIGHT INDICATION
ADVANCED APPLICATION
. SAFETY INSTRUCTIONS
. DEVICE
. INSTALLATION AND CONNECTIONS
. CONFIGURATIONS
. CONTENT . SAFETY INSTRUCTIONS
INDEX STANDARDS TO FOLLOW
2B
FEATURES
ATTENTION:
This product is certified in accordance with European Community
(EC) safety standards.
This product complies with Directive 2011/65/EU of the European
Parliament and of the Council, of 8 June 2011, on the restriction of
the use of certain hazardous substances in electrical and electronic
equipment.
(Applicable in countries with recycling systems).
This marking on the product or literature indicates that the product
andelectronicaccessories(eg.Charger,USBcable,electronicmaterial,
controls, etc.) should not be disposed of as other household waste at
the end of its useful life. To avoid possible harm to the environment
or human health resulting from the uncontrolled disposal of waste,
separate these items from other types of waste and recycle them
responsibly to promote the sustainable reuse of material resources.
Home users should contact the dealer where they purchased this
product or the National Environment Agency for details on where and
how they can take these items for environmentally safe recycling.
Business users should contact their vendor and check the terms and
conditions of the purchase agreement. This product and its electronic
accessories should not be mixed with other commercial waste.
This marking indicates that the product and electronic accessories
(eg. charger, USB cable, electronic material, controls, etc.) are
susceptible to electric shock by direct or indirect contact with
electricity. Be cautious when handling the product and observe all
safety procedures in this manual.
2B
SPECIFICATIONS
3A
3B
WIRING
CONNECTIONS

A B
ENEN
. SAFETY INSTRUCTIONS . DEVICE
STANDARDS TO FOLLOW DESCRIPTION
FEATURES
MLS4 is a waterproof standalone access control, reading EM&HID card, it uses advanced
Microprocessor, with high-capacity flash memory for 10000 users. Users can be added and
deleted via admin card, very simple to operate. The infrared remote control make the device
not only have alarm, protection, two units interlocked, anti-passback function but also can
make two units interlocked, add and delete the user on the remote control key directly.
Besides, it has low power consumption design, anti-theft alarm, door release button ect. , all
these make it convenient, safe and reliable.
Feature Description
Waterproof Design Rainproof, moistureproof , durable
Ultralow power consumption Longer working life, more stable performance
Large capacity 10000 card users
wiegand reader Can used as wiegand 26 output reader
Connect external reader Can connect EM/IC/HIDwiegand 26 output reader
two units interlocked Two units can be interlocked online
Anti-passback Single door or two doors anti-passback
SPECIFICATIONS
• Operating Voltage 12Vdc ± 10%
• Static <30mA
• Card Reading Distance 5 ~ 8cm
• Operating Temperature -10 ~ 60°C
• Operating Humidity 20% ~ 98%
• Lock Output Load 2A
• Alarm Output Load 2A
• Management card 2pcs
• It is important for your safety that these instructions are followed.
• Keep these instructions in a safe place for future reference.
• The ELECTROCELOS S.A. is not responsible for the improper use of the product,
or other use than that for which it was designed.
• The ELECTROCELOS S.A. is not responsible if safety standards were not taken
into account when installing the equipment, or for any deformation that may
occur.
• The ELECTROCELOS S.A. is not responsible for insecurity and malfunction of the
product when used with components that were not sold by the them.
• This product was designed and manufactured strictly for the use indicated in
this manual.
• Any other use not expressly indicated may damage the product and/or can
cause physical and property damages, and will void the warranty.
• Do not make any changes to the automation components and/or their
accessories.
• The customer shall not, under any circumstances, attempt to repair or tune the
automatism. Must call qualified technician only.
•Theinstallermusthavecertifiedprofessionalknowledgeatthelevelofelectronic.
He should also be able to perform electrical connections in compliance with all
applicable regulations.
• The installer should inform the customer how to handle the product in an
emergency and provide him the manual.
• This device can be used by children 8 year old or older and persons whose
physical, sensory or mental capacities are reduced, or by persons without
experience or knowledge if they have received supervision or instructions on
the use of the device in a safe manner and understood the hazards involved.
Children should not play with the device. Cleaning and maintenance by the user
must not be carried out by unsupervised children.
• Automatism powered by very low safety voltage, with electronic board/control
board/control unit.
• Before installing, the installer must verify that the temperature range indicated
on the automatism is appropriate to the location of the installation.
• In order to protect the electrical cables against mechanical stress, you should
use conduit for the electrical wires, essentially on the power cable.

A B
ENEN
. INSTALLATION AND CONNECTIONS . INSTALLATION AND CONNECTIONS
DEVICE INSTALLATION
WIRING
CONNECTIONS
1 • Drill the holes according to the distance and the dimension on the back cover, or install
the distributing box.
2 • Thread the cable through the cable hole, connect wires needed, wrapped Unused wires
with insulating tape in case of short circuit
3 • Fix the back cover on the wall with special screw
4 • Fix the front cover to the back cover with the screws
Note • Please check all wires and install front cover carefully before power on.
M2
M2 Relay
12Vdc/3A
Specil power
NC
NC COM NO PUSH GND +12V
NC
Orange
Orange
Connect Special Power
Special Power Diagram
12Vdc Specail Power Standalone for single door mode diagram
Power off the lock keep
unlocking
Power on the lock keep
unlocking
+12V
Door Connect
Exit Button
Alarm
Reset External Reader
Purple
Purple
Blue
Blue
Black Red Brown Yellow Gray White Green Pink Pink
COM
COM
NO
NO
GND Push
GND
D_IN
D1
D1
+12V
GND
GND
+12V
ALARM-
OPEN
D0
D0
RESET
Line
sequence Marks Color Description
1RESET Pink RESET
2GND Pink RESET
3D Green WG output line D
4D White WG output line D
ALARM- Gray Alarm
OPEN Yellow Exit button
D_IN Brown Door contact switch
V Red V Input
GND Black GND
NO Blue Relay NO end
COM Purple Relay Com
NC Orange Relay NC end

A B
ENEN
. INSTALLATION AND CONNECTIONS . INSTALLATION AND CONNECTIONS
CONNECTIONS CONNECTIONS
M2
NC
Orange
Door Connect
Exit Button
Alarm
Reset External Reader
Access Controller
12V Power Supply
Purple Blue Black Red Brown Yellow Gray White Green Pink Pink
COM
NO
GND
D_IN
D1
D1
D1
+12V
+12V
GND
GND
GND
+12V
ALARM-
OPEN
D0
D0
D0
RESET
Power off the lock keep
unlocking
Power on the lock keep
unlocking
M2
M2 M2
NC
NC
RESET
Orange
Door Connect
Exit Button
Alarm
Reset External Reader
12V Power Supply
Purple Blue Black Red Brown Yellow Gray White Green Pink Pink
COM
COM
GND
NO
NO
D0
GND
GND
D1
D_IN
D_IN
OPEN
D1
D1
GND
D1
+12V
GND
GND
GND
COM
+12V
+12V
ALARM-
ALARM-
ALARM-
+12V
OPEN
OPEN
D_IN
D0
D0
NO
D0
RESET
RESET
NC
Power off the lock keep
unlocking
Power on the lock keep
unlocking
12Vdc Common Power Standalone for singer door mode diagram
12Vdc Common Power Two units interlocked for two doors diagram
Anti-passback for two doors diagram
Wiegand reader mode diagram
12Vdc Common Power Two units interlocked for single door diagram
Anti-passback for single door diagram
M2
NC
Orange Purple Blue Black Red Brown Yellow Gray White Green Pink Pink
COM
NO
GND
D_IN
D1
GND
+12V
ALARM-
OPEN
D0
RESET
Orange PinkPurple PinkBlue GreenBlack WhiteRed GrayBrown YellowYellow BrownGray RedWhite BlackGreen BluePink PurplePink Orange

A B
ENEN
. CONFIGURATION
FACTORY RESET AND SET MANAGEMENT CARD PRODUCT INSTALLATION
. CONFIGURATION
Connect the two pink wires, then power on. After the sound "didi", factory reset is finished.
When indication LED turns green, it means you can set two admin cards now, read the first
card as admin add card, the second card as admin delete card, then LED turns red flash, after
this, this device can work, resetting to factory default.
Note • Reset factory default wont delete user cards, if you present the same card when second
read, the device will sound error reminding "dididi", then you can continue present another
card. If no operations within 10seconds, the device will enter working mode automatically,
parameter reset to factory default.
Connect the two pink wires, then power on. After the sound "didi", factory reset is finished.
When indication LED turns green, it means you can set two admin cards now, read the first
card as admin add card, the second card as admin delete card, then LED turns red flash, after
this, this device can work, resetting to factory default.
Note • Reset factory default wont delete user cards, if you present the same card when second
read, the device will sound error reminding "dididi", then you can continue present another
card. If no operations within 10seconds, the device will enter working mode automatically,
parameter reset to factory default.
Add users by remote control:
Delete users via remote control:
Safe mode setting:
ADMIN SETTING ON KEYPAD
Entering admin
operating mode
Press factory default: 999999
Note • All the below operations need be under programming
mode.
master code
*#
Change the master
code
Press
Note • Master Code length:6~8 digits
Add consecutive
number card
Press
Add consecutive number cards users, card quantity 1-9999, green
fast flash
Delete all users Press
Note • This operation will delete all users, but admin card wont
be deleted
Use ID Number to add
user
Press
Note • 1 card number must be 8 or 10 digits, if the card number is
less than 8 or 10 digits, input 0 before the card number 2 press #
confirm, press last #finish, press *exit.
Read card to add user Press
Read card to delete
user Press
Normal mode (factory
default) Press
Dead mode
Press
Read invalid cards 10 times continuously within 10minutes, the
device be dead for 10 minutes
Alarm mode
Press
Read invalid cards 10 times continuously within 10minutes, both
external alarm and built-in alarm sound.
Door open time
setting
Press
Range "0~99seconds", 0mS equates 50mS.
Use card NO. to delete
user
Press
card quantity
2000
1#
#
#
#
#
#
read card
1#
read card
2
3
3
3
4
0
1
2
0~99
8 or 10 digits card number
8 or 10 digits card number
2
read card #
read card #
#
#
#
8 or 10 digits card number
new code
0#repeat new code
0#
card number
1#card number #
...
...
Alarm time setting
Press
Note • Range "0~3minutes" factory default 1 minute.
#
50~3

A B
ENEN
. CONFIGURATION
PRODUCT INSTALLATION USER OPEN DOOR OPERATION
. CONFIGURATION
Red light mode setting:
Add user:
External alarm and built-in alarm both sound
Inside buzzer alarm after door close
Delete user:
Interlock setting:
Anti-passback mode setting:
Static disable mode Press Read user card Read valid user card, door will be open,but admin card cant open
the door.
Press
Read
Close door or press
Press
Close interlock
(factory default) Press
Disable anti-passback
(factory default) Press
Enable anti-passback
host mode Press
#
#
#
#
#
#
6
7
8
8
0
0
0
1
Static normal mode
(factory default) Press
Open interlock Press
#
#
6
7
1
1
Enable anti-passback
subsidiary mode
Press
Note • Details will be illustrated in Advanced Application below.
#
8 2
ADMIN CARD OPERATION
REMOVE ALARM OPERATION
read admin add card
user card
user card
read admin delete card
read admin delete card
read admin add card
read user card 1
admin card
admin card
read user card 1 read user card 2
read user card 2
admin pin
admin pin
... ,
... ,
finally
alarm will be removed.
alarm will be removed.
or input
or input
finally
exit.
,
,
,
,
exit.
OPERATION LED COLOR BUZZER
Initialization Orange DiDi
Static Red Flash
Valid press key Di—
Enter programme Red Di—
Setting Orange Di
Exit Red Flash Di—
Operation Failed DiDi
Lock open Green Di—
Alarm Red Quick Flash Alarm
Add sequential No. card Green Quick Flash
SOUND AND LIGHT INDICATION

A B
ENEN
1• Two units for single door
Install one at indoor and the other at outdoor, indoor one as controller, outdoor
one as reader. The difference between two units interlocked for single door and
standalone for single is below:
1.1 • Add users on both unit, both indoor user data and outdoor data can be
shared, users can be up to 20000.
1.2 • The setting of the two device must be the same, when admin pin setting is
different, outdoor unit can’t open the door with saved users data.
2• Two units interlocked for two doors
Install two controllers for two doors, control two locks separately, set interlocked
for two units, open door contact. The other door is locked when door is open.
The other door can be open after close the door. The device can’t control
another electric lock, data can’t share between different units. This function
mainly apply for bank, prison etc.
3• Anti-passback for Single door
Install a common reader outdoor (or use this device without any card No. for
reader). Install this device outdoor and set it as anti-passback host mode. In this
case, the two units consist of an anti-passback system for single door, mainly
apply to controlling enter and exit for single door. Details operation is as below:
3.1 • Set necessary functions and add user card on the host device.
3.2 • Users can only present the card on the external reader to enter, and then
present the card on the host device to exit, then, present card on the external
reader to enter, do it like this, enter legally, and then exit legally. Users cant
enter or exit at continuous 2 times.
4• Anti-passback for two doors
Install one device on Door 1under anti-passback subsidiary mode,Install one
device on Door 2 under anti-passback host mode, in this case, the two units
consist of anti-passback for two doors, mainly apply for one-way in and out for
double doors like parking. Functions as follows:
. CONFIGURATION
ADVANCED APPLICATION ADVANCED APPLICATION
. CONFIGURATION
4.1 • Set necessary functions and add user card on the host device.
4.2 • Users can only present the card on the subsidiary device to enter, and then
present the card on the host device to exit, then, present card on subsidiary
device to enter, do it like this, enter legally, and then exit legally. Users cant
enter or exit at continuous 2 times
Table of contents