— 1 — — 2 — — 3 —
NPort DE-211
Quick Installation Guide
Sixth Edition, May 2006
1. Overview
Welcome to Moxa NPort Express DE-211, a compact palm-sized data
communication device that is used to control RS-232/422/485 serial
devices over a TCP/IP based Ethernet.
2. Package Checklist
Before installing NPort Express DE-211, verify that the package contains
the following items:
y1 NPort Express DE-211 Universal Serial Device Server
yNPort DE-211 Quick Installation Guide
yPower Adaptor
yNPort Document & Software CD
yProduct Warranty Booklet
Optional Accessories
yNP21101 RS-232 cable: DB25(M) to DB9(F), 30 cm
yNP21102 RS-232 cable: DB25(M) to DB9(M), 30 cm
yNP21103 DB25 Terminal Block Kit for RS-422/485
yDK-35A DIN-Rail Mounting Kit (35 mm)
Notify your sales representative if any of the above items is missing or
damaged.
3. Hardware Introduction
The NPort DE-211 device server has one female DB25 serial port. The
four DIP switches located on the rear panel are used to select between
RS-232 COM mode, and one of four data modes: RS-232, RS-422,
4-wire RS-485, and 2-wire RS-485. See the “DIP Switch Settings &
Explanation” section for details.
RJ45 10BaseT
Ethernet port
Reset button*
Power
input DIP
Switches
Female DB25
serial port
DIN-Rail
screw hole
Wallmount
screw hole
DE-211 RS-232/422/485 Device Server
Express
PWR
SW1 Serial
Connection
RS-232
Console
Data
Comm
ON
OFF
SW2
ON
ON
ON
ON
OFF
OFF
Link
Ready
Serial Tx
Serial Rx
SW3
OFF
ON
OFF
ON
OFF
ON
Serial Interface Mode
RS-232
RS-422
4-Wire RS-485 by RTS
4-Wire RS-485 by ADDC
2-Wire RS-485 by RTS
4-Wire RS-485 by ADDC
SW4
ON
ON
OFF
OFF
OFF
ON
Serial
DC-IN SW RESET 10BaseT
Ethernet
Top Panel
Front Panel
Rear Panel
*Reset Button—Press the Reset button continuously for:
a. 3 sec to erase the password
After 3 sec, the Ready LED will flash on/off every half second.
Release the reset button at this time to erase the password.
b. 10 sec to load factory defaults
After 10 sec, the Ready LED will flash on/off every fifth of a second.
Release the reset button at this time to load factory defaults.
LED Indicators (top panel)
LED Name LED Color LED Function
red Power is on.
PWR off Power is off, or power error
condition exists.
orange 10 Mbps Ethernet connection.
Link off Ethernet cable is disconnected, or
has a short.
green NPort Server system is ready.
Ready off NPort Server has malfunctioned.
green Serial data is being transmitted.
Serial Tx off Serial data is not being
transmitted.
orange Serial data is being received.
Serial Rx off Serial data is not being received.
4. Hardware Installation Procedure
Placement Options
In addition to placing the
DE-211 unit on a
desktop or other
horizontal surface, you
may also make use of
the DIN-Rail or Wall
Mount options, as
illustrated here.
Wall Mount
DE-211 RS-232/422/485 Device Server
Express
PWR
SW1 Serial
Connection
RS-232
Console
Data
Comm
ON
OFF
SW2
ON
ON
ON
ON
OFF
OFF
Link
Ready
Serial Tx
Serial Rx
SW3
OFF
ON
OFF
ON
OFF
ON
Serial Interface Mode
RS-232
RS-422
4-Wire RS-485 by RTS
4-Wire RS-485 by ADDC
2-Wire RS-485 by RTS
4-Wire RS-485 by ADDC
SW4
ON
ON
OFF
OFF
OFF
ON
Serial
DC-IN SW RESET 10BaseT
Ethernet
DIN-Rail
DIP Switch Settings & Explanation
The top panel of DE-211 contains the following table, which describes
how to set up the serial port using the four DIP switches located on
DE-211’s rear panel.
SW2 SW3 SW4 Serial Interface Mode
SW1 Serial
Connection OFF OFF OFF RS-232
OFF ON ON RS-422
ON RS-232
Console ON OFF ON 4-Wire RS-485 by RTS
ON ON ON 4-Wire RS-485 ADDC
ON OFF OFF 2-Wire RS-485 by RTS
OFF Data
Comm ON ON OFF 2-Wire RS-485 ADDC
Switch SW1 controls the function of the serial port. Note that after
changing the setting of SW1, DE-211 will reboot to initialize the new
setting. You must wait a few seconds for the green Ready light to blink
off and then on again, indicating that the function of the serial port has
been changed. Switches SW2, SW3, and SW4 control the serial port’s
data communication Interface Mode. (RTS stands for Ready To Send and
ADDC stands for Automatic Data Direction Control.)
Keep the following points in mind when setting the DIP switches:
yTo use the serial port as an RS-232 console connection, such as when
using MOXA PComm Terminal Emulator or HyperTerminal, set SW1
to the ON position.
ySome setup procedures can be carried out through a Telnet connection,
in which case data is transmitted through DE-211’s Ethernet port.
However, you must set SW1 to the OFF position to establish a Telnet
connection.
P/N: 1802002112400