moxaLight moxaLight User manual

ACU PUNCTURE
USER MANUAL
© 2019 MOXALIGHT.com
LIGHT

DISCLAIMER:
THE MOXALIGHT PRODUCTS ARE PROVIDED "AS IS", WITHOUT WARRANTY OF ANY KIND,
EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF
MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT. IN NO
EVENT SHALL THE MOXALIGHT AND MOXALIGHT AUTHORS OR COPYRIGHT HOLDERS BE
LIABLE FOR ANY CLAIM, DAMAGES OR OTHER LIABILITY, WHETHER IN AN ACTION OF
CONTRACT, TORT OR OTHERWISE, ARISING FROM, OUT OF OR IN CONNECTION WITH THE
MOXALIGHT PRODUCTS OR THE USE OR OTHER DEALINGS IN THE MOXALIGHT.
For an suspected or known illness or health concern, alwa s consult with our ph sician or health
care provider prior to the purchase or use of an moxaLi ht products. moxaLi ht have attempted to
present information from the literature, books and other references as well as information as
accuratel as possible, but ou should be aware that the Food and Drug Administration has not
approved or evaluated moxaLi ht products. The use of moxaLi ht products and its user manual
content is at our own risk. In no event shall moxaLi ht, its owners and/or administrators, its
suppliers, or an third parties mentioned on be liable for an damages or injuries however caused,
occurring during or after using an moxaLi ht products. moxaLi ht assumes no responsibilit for the
use of and self-diagnosis and/or treatment with the moxaLi ht products. moxaLi ht products should
not be used as a substitute for medicall supervised therap . If ou suspect ou suffer from clinical
deficiencies, consult a licensed, qualified medical doctor. It is important that ou understand wh no
claims can be made about the products ou order from moxaLi ht and we cannot suggest the use of
an product that will effect a cure or affect a s mptom/ailment. Before starting moxaLi ht products
usage, it’s alwa s wise to check with a medical doctor. None of the products or information available to
the public are intended to be a treatment protocol for an disease state, but rather are offered to
provide information and choices regarding support for various health concerns. None of the
information is intended to be an enticement to purchase and ma not be construed as medical advice
or instruction. No action should be taken solel on its content; regardless of the perceived scientific
merit, instead readers should consult health care professionals on an matter related to their health.
The information obtained from referenced materials are believed to be accurate, as presented b their
respective authors, but moxaLi ht assumes no liabilit for an personal interpretation. Readers,
previous and future customers who fail to consult their Ph sicians prior to the purchase and
subsequent use of an moxaLight products, assume the risk of an adverse effects. The use of an
therap for an reason,is neither, implied nor advocated b moxaLi ht.
Caution:
Some of the moxaLi ht products components contain elements that are not ordinaril found in t pical
medical equipment and ma produce undesired effects, therefore in-discriminant use of an
moxaLi ht products is not recommended except under the direction of a trained health care
professional. For an suspected or known illness or health concern, alwa s consult with our
ph sician or health care provider prior to the purchase or use of an moxaLi ht products.
moxaLi ht products ma be powered from a power suppl connected to AC voltage. To reduce the
risk of electric shock moxaLi ht products have to be serviced and operated b trained personnel onl .
moxaLi ht products ma be alternativel powered from a batter pack for mobile usage. Charging the
batter pack simultaneousl with powering the moxaLi ht products is strictl prohibited.
Warnin :
When using moxaLi ht products, basic safet precautions should alwa s be followed to reduce the
risk of fire, electrical shock, burn and personal injur . If an thing unusual occurs STOP USING
moxaLi ht products immediatel !
To reduce the risk of fire and electric shock do not expose moxaLi ht products to water, rain or
moisture. Do not abuse electrical cords. Do not leave moxaLi ht products unattended. Guard against
electric shock. Prevent bod contact with exposed wires or grounded surfaces or grounded surfaces
like pipes or appliances. Do not use near water. Alwa s inspect moxaLi ht electric cords and light
emitters and avoid damaged ones. moxaLi ht products light sources ma be ver intense please
avoid e e contact. If heat is generated in excess STOP USING moxaLi ht products and disconnect
power immediatel !

SCAN HERE!
Please watch our instructional video:
http://moxalight.com/video
OPTIONS:
1. LIGHT EMITTERS
(acupuncture point stimulation)
2. 128L HELMET
(rejuvenation, meditation)
3. DUAL PACIFIER
(stimulation, rejuvenation)
4. 64L PAD
(li ht therapy)
The center piece of the moxaLi ht is an electronic device defined as the controller and is
capable to generate specific light patterns.
The controller has several factor PRESET-s for different light patterns, one can select
from the round-robin top left button.
Several MODE-s are switch-able from the center left button.
Customized light patterns can be selected with the embedded WI-FI access point and
with the help of a smart phone, tablet or PC, the light pattern set-up page can be accessed
and edited. WI-FI setup and access point information is displa ed on the controller status
OLED displa . WI-FI can be turned on/off with the bottom left button.
Lights can be turned off after a number of minutes with the help of a built in TIMER.
Timer round robin time setup is controlled b the top right button and each press adds 10
minutes.
For faster light intensit dimming control, the center right button will round robin 20%
decrements per push.
The right bottom button, when lit, will change the frequenc for beats difference or
pulse modes .
The top displa AUX OUTPUT indicator shows the auxiliar output status. The auxiliar
output is placed on the lateral side of the controller and connects to control the L128 helmet

and the 64L pad. If RGB shown on displa , the numbers under will indicate the box, pad and
helmet r, g, and b color intensit values. When SEQ is displa ed, different memor maps of
rgb values are recalled. The s mbol M followed b a number will indicate the memor set
active. The MODE button selects the sequence direction and the memor recalled set in a
round-robin st le.
To switch any function keep selected button pressed for approximate 2 seconds or till
status display confirms and re isters the selected chan e.
MoxaLi ht controller setup can provide several functions. Different light devices can be
connected and certain procedures can be performed according to the following table:
FUNCTION vs
DISPLAY
PRESET MODE Top
center
controller
oled
displa
OUTPUT FREQ WEB
Front USB-A
connectors
for
Light emitters or
Dual Pacifier
Side micro
connector
for
pad or helmet
Acupuncture
point
stimulation
acute cold
RGB
606
Recalls factor
presets for light
patterns according
to the selected
PRESET and
MODE
Recalls factor
preset color
showed under the
RGB displa .
The whole arra
or helmet will
show the same
color. For other
colors and
intensities use
WEB interface.
No
displa
Customize
Light
patterns
warm 066
subacute cold 060
warm 660
chronic cold 006
warm 600
Meditation beats main
321
Main freq.
Round robin
decrements
beat Beat freq.
Round robin
increase
Light
Therap pulse
alt 600/
303 Alternates two colors
Scroll
Frequenc
iso 600/
000 Alternates color on with off
seq/1
SEQ
1/4
Scrolls one
color with the
x/4 fill factor,
direction minus
or plus
Recalls set 1
of 4 memor
sequences
1/seq
seq/2
2/4
Recalls set 2
of 2 memor
sequences
2/seq
seq/3 3/4
Recalls set 3
of 4 memor
sequences
3/seq

Acupuncture point stimulation cheat-sheet instructions:
User instructions Easy to use as 1-2-3-4
1.
Identif the specific acupuncture points, b
contacting an accredited professional or b
internet search. Use a search engine b t ping
“...acupuncture points”. From images search
select the most appropriate and effective
acupuncture points for stimulation.
2.
Appl light emitters on top of the desired
acupuncture points previousl identified. The
light emitter is lozenge shaped and has a
circular opening for light to come out on one
side. Place the h poallergenic double sided
sticker with the hole on top of the light opening
for the holes to match. Stick the lozenge on top
of the point to be stimulated.
3.
Connect the light emitters USB male connector
to the moxaLi ht controller USB female
connectors.
4.
Select one factor preset for the light pattern b
pressing the top and center buttons located on
the left side of the controller box.
Enjoy 20 to 40 minutes of relaxation while your inner ener y ets balanced.

The web setup interface provides visible and invisible pulsatin frequencies to ether
with a li ht color. Two sets of each can be alternated by settin a to le time.
For the visible pulsatin frequency numbers between 1 and 50 can be entered in the
specified input boxes:
2 to 4 Hz Addresses ACUTE pain and inflammation.
4 to 10 Hz for SUB-ACUTE pain, related to joint pain and arthritis.
10 to 50Hz for CHRONIC pain, including muscle tightness
For the invisible pulsatin frequency input boxes, marked as bias frequency ,numbers
between 1 and 1500 can be entered.
F-73 Hz Stimulates osteoid activit such as endomorfine, CCK8 and orphaniine,
improves circulation.
G-146 Hz Stimulates sub-acute conditions, helpful in reducing inflammation
associated with injuries and infections. Is called the "universal frequenc " because
most problems involve inflammation. Tr for an condition.
A-292 Hz Tones tissue and triggers healing. This is called the "double universal
frequenc " in acupuncture.
B-584 Hz Use for circulator and l mphatic stimulation in chronic conditions.
C-1168 Hz Stimulates relaxation.
For the color input boxes, each holds 3 di its, from 0 to 9 ran e. Each di it represents
a primary color: first is for red, second for reen, and third for blue. By placin a
number between 000 and 999 different primary colors intensities can be mixed and
colors can be obtained. I is considered the desired intensity.
RED R=I, G=0, B=0 Good for circulation, chronic illness, strengthens
kidne s, heart, muscles, blood, lungs, bones.
ORANGE R=2x I/3, G= I/3, B=0
Good for depression, cramping an where in bod ,
relaxant, sclerosis, heart disease, boosts immune
s stem, circulation, raises blood pressure.
YELLOW R= I/2, G= I/2, B=0
Good for digestion, stomach, gall bladder, liver, immune
s stem, fortifies endocrine and nervous s stems, helps
chronic to become acute.
GREEN R=0, G= I, B=0 Good for liver, swelling or growth, anti-inflammator ,
gout, diabetes, promotes health bones, painful joints,
allergies.
TURQUOISE R=0, G= I/2, B= I/2 Good for immune s stem, skin, mental relaxation, acidic,
fortifier, regulates lung/large intestine s stems.
BLUE R=0, G= 0, B= I
Anti-bacterial, anti-infection, anti-cramping, headaches,
facilitates restful sleep, pain relieving, nervousness,
insomnia, hemorrhage, herpes, warts, lowers blood
pressure, fever.
VIOLET R= I/2, G= 0, B= I/2 Good as for menopause, spleen, sedative, relaxant,
l mphatic relaxant, anti-viral.
MAGENTA R= I/3, G= 0, B=2xI/3
OLIVE R= I/2, G= I/2, B=0
WHITE R= I/3, G= I/3, B= I/3

Meditation, optical beats instructions:
Similar, with the bin-aural beats, two light emitters or the dual pacifier are used. The pulsation
frequencies for each source is slightl different:
main source beat source difference
Focus, crown 21 6 15
Creativit , navel 21, 14 11, 4 10
Relaxation 21 15 6
Sleep 21 18 3
Chanting 21 17 4
Intuition,heart 21, 8 15, 4 6
Healing,root 21 13 8
Alpha 21 12 9
Euphoria 21 1 20
third e e 17 4 13
throat 16 4 12
sacral 15 4 9
root 12 4 8
The MODE button can be used to select which frequenc can be modified b displa ing main
or beats. The FREQ button changes the frequenc selected b MODE in a round robin st le.
Also the web setup interface can be used to modif the beats preset frequencies.
Li ht therapy, Pulse instructions:
Under the pulse preset several modes are available.
1. alt alternates between two preset colors with the FREQ displa ed frequenc .
2. Iso turns on an off one preset color with the frequenc displa ed under FREQ.
3. 1/4, 2/4 and 3/4 recalls memor sets and have different outcome for the front and .
For the front connectors; the effect is similar with the chasing lights with 4 circuits. In
1/4, one circuit is on from four. 2/4 , onl two circuits are on and for 3/4, three circuits are on
from four. Chasing speed is determined b the value displa ed under FREQ. The assigned
button can modif the chasing frequenc in a round robin st le. The chasing direction can be
modified with the MODE button.
For the auxiliar side connector; the controller recalls 2 (2/4) to 4 (1/4 , 3/4) light arra s
maps. The recall frequenc and direction can be also changed from FREQ and MODE
buttons.

Eas steps on how to access the moxaLi ht embedded WI-FI web server setup page:
1.
Turn on the embedded wi-fi access point on
the MOXALIGHT controller.
If controller main OLED displa shows WI-FI
off, press the bottom right button to turn it
on. The OLED will show the status plus
information of the wi-fi access point name
and the access password.
2.
With wi-fi on three scenarios are available:
•A-connect to an existent wi-fi with internet connection( if ssid and pass are alread in
process is automatic)
•B-setup wi-fi ssid and password for an existent wi-fi with internet connection
•C-light patterns setup- with he built in wi-fi access point AP or with the ip address
given for the existent wi-fi with internet connection.
2 A
When controller is connecting to an existent
previousl set internet connection the pls
wait text appears on displa next to the WIFI
mark.
Under it will displa the SSID and password it
tries to connect to. If successful read 2C
instructions otherwise 2B.
2 B
To confirm the node for entering an existent
wi-fi internet connection the ssid setup word
appears on displa next to the WIFI text.
Under it will displa the SSID and password
ou need to connect to with our smart
device. Once connected, set our browser
address input box to the ip specified on
displa . Please follow instructions from 5.

2 C
If step presented in 2A is successful then the
controller should be connected to our
internet wi-fi network.
Reconnect our smart device to our existent
internet wi-fi connection and set our browser
address this time to the new displa ed ip. The
light setup page will show the light setup
page as shown in 7
3.
Connect to an access point name with the
specific password, both displa ed on the
controller's OLED main screen.
Use a smart phone, tablet or portable
computer with wi-fi to connect. Open the wifi
setup and connect to the desired ssid with the
given password.
Use an html5 browser and t pe the given ip
address into the address input box. T ping
the ip in the search engine input box will not
work.
Browser will show up either wi-fi setup page
or light setup page. Each mode is actuall
specified on the controller displa .
4.
If the unit cannot connect to an existent wi-fi
or user does not use wi-fi setup page , the
controller will switch after 5 minutes to the
AP (access point) mode where the light setup
page can be accessed directl b connecting
to the displa ed SSID and PASS. Connect
and bring up a html5 browser. Just t pe in
our browser address input box the ip shown
on displa .
The wi-fi setup page will be shown on our
web browser.

5.
If in wi-fi ssid setup mode is on the following
setup web page will be shown.
Select the desired wi-fi SSID b pressing the
button wit its name and enter the password.
Submit and wait till the controller connects to
the specified SSID. If successful, the
controller displa will show that unit is
connected to SSID... with PASS *. Please
reconnect to our new SSID and access our
browser.
6.
If in WIFI web setup mode the following light
patterns setup page will be shown.
Fill the desired values into the input boxes.
After pressing the browser submit button, the
controller will receive the new values and will
displa MODE web.
.
Table of contents
Popular Personal Care Product manuals by other brands

Waterpik
Waterpik Waterflosser WP811 quick start guide

Medisana
Medisana 60256 instruction manual

Ever
Ever Pharma D-mine Pump Instructions for use

Paraffin Wax Works
Paraffin Wax Works 301476 Important instructions

Becker
Becker Cervical Orthosis Care and use instructions

Sunrise Medical
Sunrise Medical Jay Ion owner's manual