MSTRONIC SOL10P24 Series User manual

Mstronic Co., Ltd.
SOL10P24 Series
Solar/PoE Charge Controller + Gigabit PoE Injector
USER’S MANUAL

User’s Manual SOL10P24 Series
Features:
Dual Inputs, from solar panel and/or PoE (Solar First) to charge
24V battery,
Dual outputs: PoE output on front and/or terminal block on rear
Built-in DC/DC converter, with passive PoE output, 24V, 48V, 56V
available.
Active PoE Output support 802.3at handshake (option)
DIN Rail Mountable
Support Gigabit Ethernet
Applications:
Remote Power Systems; Surveillance, Sensors
Wireless Station; AP/Client/Repeaters
UPS Systems; Lighting, Fences, Gates
Protection:
Battery Polarity Reverse Protection
Battery Over Charge Protection
Battery Over Discharge Protection
Solar Panel Polarity Reverse Protection
Solar Panel Over Charge Protection
Output Short Circuit Protection
Output Over Voltage Protection
POE Output Short Circuit Protection
Externally fused with a standard replaceable fuse

User’s Manual SOL10P24 Series
Panel Description:
Item
Name
Descriptions
1
POE :
PoE power input indicator: the LED lights when the PoE input jack (the
lower jack) has 36V~57V input.
2
SOL :
Solar power input indicator: the LED lights when SOL terminal is
connecting to a solar panel and the solar panel input voltage is over 24V.
3
CHA :
Charging indicator: the LED lights when BAT terminal is connected to
battery and charging
4
LOA :
Loading indicator: the LED lights when the rear panel output terminal is
connecting to a device and offering power.
The LED always on when power ready.
5
REV :
Battery polarity reverse indicator: the LED lights when the battery
polarities are reversed. (detail description see Sec. 5.1)
6
IN :
PoE Input Jack: the lower RJ45 jack, used for PoE input. Allowed input
voltage 36~57V
7
OUT :
PoE Output Jack: the upper RJ45 jack, used for PoE output; Output
voltage depends on what model you selected.
8
Fuse
Fuse: for output over current protection, limiting the battery output
current <= 10A.
9
SOL :
Solar Panel Terminal: used to connect the solar panel.
10
BAT :
Battery terminal: used to connect the battery.
NOTE: ALWAYS CONNECT THIS TERMINAL FIRST.
If solar panel or PoE source is installed before the battery, and if the
polarities of battery are reversed, then the fuse will be burnt.)
11
LOA :
Load Terminal: for wire size up to 12AWG, the output voltage is the
same as battery voltage.

User’s Manual SOL10P24 Series
Operation Guide
1. Connect the battery to the BAT terminal. Make sure the polarities are
correctly connected. Sequentially connect the solar panel to SOL terminal
and connect POE source to PoE input (lower) jack. (If solar panel or PoE
source is installed before the battery, and if the polarities of the battery be
reversed, then the battery will be disconnected.)
2. Make sure the battery is properly connected to the unit. If no battery is
connected, then the voltage at BAT terminal will be approx 27.3V+0.5V
3. The solar panel cannot be used stand alone without battery connected.
4. When a solar panel and PoE input are connected to the charger, if the
voltage of solar panel is higher than 36V, then solar panel is always the
main power source of the charger.
5. When charge from solar panel, as the battery full and turn to floating
stage, the CHA light will start flash.
6. When charge from PoE, as the battery full, the CHA light will be turn off, if
the CHA is always flash, that means the input wattage lower than the
required minimum wattage. If only charge battery, the minimum input
wattage is 30W, if full load, the minimum input wattage is 80W.
7. When battery connect to BAT terminal and with valid voltage, then the
LOA indicator will always light on even no load connected.

User’s Manual SOL10P24 Series
8. It can be two separate outputs on the rear panel, make sure the total
draw is not over the limit.
9. The V- of PoE input, Solar input, and battery(-) are not the same
grounding, must be properly isolated.

User’s Manual SOL10P24 Series
Electrical specifications
1. INPUT
1.1 Two Input Source:
A. Solar Panel : 30V~55V,
B. POE : 36V~57V (only use 4 pairs injector for more than 35W input.)
2. OUTPUT
Model No.
Output 1
(at rear terminal)
Output 2
(at front/upper RJ45)
SOL10P24-24BNN
24V/10A
(as Bat. Volt.)
24V/1.25A
(45+/78-)
(regulated)
SOL10P24-48ANN
24V/10A
(as Bat. Volt.)
48V/0.625A
(12-/36+)
(regulated)
SOL10P24-48ANR
24V/10A
(as Bat. Volt.)
48V/0.625A
(12+/36-)
(regulated)
SOL10P24-48BNN
24V/10A
(as Bat. Volt.)
48V/0.625A
(45+/78-)
(regulated)
SOL10P24-56B1N
24V/10A
(as Bat. Volt.)
56V/0.625A
(45+/78-)
(regulated)

User’s Manual SOL10P24 Series
3. Battery Charge Current:
A. Solar Panel: depends on the solar panel, 10A max,
B. POE: fixed current, 2.0A max
4. Battery Types: 24V AGM Battery
5. Protection:
5.1 Battery Polarity Reverse Protection:
If only battery connected to terminal, when the battery polarities
were reversed, the model will stop output and REV indicator light
on. When the battery be removed and re-connected to terminal,
the function will be disable, if there is PoE power sources
connected, when the battery polarities reversed, the battery will be
disconnected.
5.2 Battery Over Discharge Protection:
Cuts off the load when the battery voltage is lower than 20V + 0.3V,
and auto recover when the battery voltage returns to 24.3V + 0.3V
5.3 Battery Over Charge Protection:
Fuse control, over 15A, the fuse will be burnt.
5.4 Solar Panel Polarity Reverse Protection:
When solar panel polarities be reversed, the charger stop output, it
won’t damage the charger or end device
5.5 Solar Panel Over Charge Protection:
When charge current over 15A, the fuse will be burnt.

User’s Manual SOL10P24 Series
5.6 Output Short Circuit Protection:
When the rear output terminal or PoE output be short circuit,
protection be active, the product stop output and auto-recover
when the terminal back to normal connection.
5.7 Battery Output Current Limit:
The fuse will be burnt when battery output current over 15A
5.8 Load Output Voltage Limit:
The output voltage of the rear terminal is the same as battery.
5.91 POE to Battery Charger Voltage :
Float = 26.8V ± 0.2V
Equalize = 28.4V ± 0.2V
5.92 SOLAR to Battery Charger Voltage :
charger go to Voltage = 28.8 V ± 0.2V
6. GENERAL DESCRIPTION
6.1 Operation Temperature: -40 - +60 Degree
6.2 Storage Temperature: -40 - +85 Degree
6.3 Operation Humidity: 5% - 90% non-condensing
6.4 Cooling: Free air cooling
6.5 SIZE 150*118*40mm (L*W*H)

User’s Manual SOL10P24 Series
7. Pin out: @1000M
RJ-45 Input (Data & Power)
Compliant to 802.3af/at
RJ-45 Output (Data & Power)
Depends on individual models
Pin
Symbol
Description
Symbol
Description
1
(+/-)Vdc + BI_DA+
power(+/-)+Data Pair A+
(+/-)Vdc + BI_DA+
power(+/-)+Data Pair A+
2
(+/-)Vdc + BI_DA-
power(+/-)+Data pair A-
(+/-)Vdc + BI_DA-
power(+/-)+Data pair A-
3
(+/-)Vdc + BI_DB+
power(+/-)+Data Pair B+
(+/-)Vdc + BI_DB+
power(+/-)+Data Pair B+
4
(+/-)Vdc + BI_DC+
power(+/-)+Data Pair C+
+Vdc + BI_DC+
power(+)+Data Pair C+
5
(+/-)Vdc + BI_DC-
power(+/-)+Data Pair C-
+Vdc + BI_DC-
power(+)+Data Pair C-
6
(+/-)Vdc + BI_DB-
power(+/-)+Data Pair B-
(+/-)Vdc + BI_DB-
power(+/-)+Data Pair B-
7
(+/-)Vdc + BI_DD+
power(+/-)+Data Pair D+
-Vdc + BI_DD+
power(-)+Data Pair D+
8
(+/-)Vdc + BI_DD-
power(+/-)+Data Pair D-
-Vdc + BI_DD-
power(-)+Data Pair D-
Note :
1. the model is isolated design.
2. The PoE output can be 2 pairs or 4 pairs, mode A or B, depends on
individual models.
This manual suits for next models
5
Table of contents
Other MSTRONIC Controllers manuals
Popular Controllers manuals by other brands

Eaton
Eaton xComfort CSEZ-01/19 Assembly instructions

Mitsubishi Electric
Mitsubishi Electric PAR-U01MEDU Smart ME Instruction book

THOMSON
THOMSON MEC 310 - APLLICATION NOTES EXTERNAL I-O... manual

Epever
Epever Tracer-AN Series user manual

SBC
SBC PCD2.M5 Series manual

GM Lighting
GM Lighting RGBW-DMX-WC installation guide