⑥Zero Set Switch :Apply this switch at range switch「DCA」. By pressing Zero Set Switch,
「△」mark on LCD. (It will take approx. 5 –6 seconds for zero set).
⑦LCD Display :Digital display for measured value, unit symbol and battery condition.
⑧Hand Strap :Apply this strap to wrist during measurement to prevent dropping
the instrument.
⑨Battery Compartment :Batteries are installed (back side).
⑩Voltage Input Terminal: Voltage Input Part (Red/Black). In case of DC, red terminal is + side.
MEASURING METHOD
To operate the instrument safely, observe strictly the contents of Caution/Warning stated.
●DC Current(A)Measurement
1)Set range switch ③from OFF to A position.
2)By zero set switch ⑥, make zero adjustment before measurement.
3)Open clamp CT and apply CT to the one conductor to be measured(locate the conductor to be
measured at the center of CT). Close CT firmly (in case of DC current, set the current
direction same as to the indication sticker of the instrument).
4)Read the displayed value. In case of over range (more than 165A), 「OL」will appear on LCD.
5)In the place where the display can hardly read, utilize data hold switch ⑤.
6)After measurement, set range switch ③to OFF.
●AC Current(~A)Measurement
1)Set range switch ③from OFF to ~Aposition.
2)Open clamp CT and apply CT to the one conductor to be measured(locate the conductor to be
measured at the center of CT). Close CT firmly.
3) Read the displayed value. In case of over range (more than 165A), 「OL」will appear on LCD.
4) In the place where the display can hardly read, utilize data hold switch ⑤.
5) After measurement, set range switch ③to OFF.
●Percentage for DC Current contained in AC Current(%)
1)Set range switch ③from OFF to A position.
2)By zero set switch ⑥, make zero adjustment before measurement.
3)Set range switch ③to %position.
4)Open clamp CT and apply CT to the one conductor to be measured(locate the conductor to be
measured at the center of CT). Close CT firmly
5)Read the displayed value. %=(DC Current ÷AC Current)×100
6)Conditions of Over Range Display「OL」
・Calculated Value becomes more than 100.0%
・In case of AC current 0A
・In case of AC current more than 165A
・In case of DC current more than 165A
7)In the place where the display can hardly read, utilize data hold switch ⑤.
8)After measurement, set range switch ③to OFF.