Mystic Romance Di Aroma Mars User manual

thenaturearoma.com
SCENT EQUIPMENT USER MANUAL
EXPERT IN FRAGRANCE
DELIVERY SYSTEM SOLUTION
SAFETY EFFECTIVE ENVIRONMENTAL

thenaturearoma.com
PRODUCT INTRODUCTION
This scent machine is for small commercial area. It uses advanced atomization
technology to make the liquid oil into fog, then can diffuse the fragrance into the
air quickly. The machine has a fan installed, it can be used directly to diffuse the
fragrance and, also can be connected to the HVAC system. It has a timer
program to adjust different aroma concentration to suit for different space and set
the working time for everyday and 7-day timer program to suit for customers'
different request.
Parameter:
️Oil bottle: 200ml
Voltage DC110V
Power: 5w/8w
Coverage:100-300m3
Noise:<42dba
Weight: 2.8KG
•Spare Parts: Scent diffuser, Power adapter, User Manual, Atomizing-
Core, Screws etc.
•There is a timer program to set different working day / different working
period / different aroma concentration to suit for different usage.
•Put oil into the bottle, then machine working can let you feel good smell in
your places all the time.

thenaturearoma.com
Step
First: Use the key to open the machine
Second: Move the cover to the left and take it down
Third: Remove the oil bottle clockwise, add or replace
the oil into the bottle, then install oil bottle against clockwise.
Fourth: Point the cover to the small holes,
move the cover to the right and fix it, finally use the Key to lock it.

thenaturearoma.com
SET THE SYSTEM TIME
Firstly, to press [SET), the LCD display showed "hours" figure will flash, then
press (UP/DOWN) to adjust hour. Press (SET) at second time. Hour adjustment
finished. The minutes figure will flash, then press (UP/DOWN) to adjust the
minutes. Press (SET) at the third time, Minute's adjustment finished. The
indicated date will flash, press [UP/DOWN) to adjust the current date, finally
press (SET) at fourth time, all function setting finished.
SET UP THE WORK TIME
•MODE: Adjust different function including your local current time different
groups working periods, Work/Pause Inter time aroma concentration.
Press (MODE) for 10 seconds restore the factory settings.
•SET: Start program Setting by flexible setting including Time, Date, aroma
concentration. Then press (SET) for seconds to lock / unlock the previous
setting
•UP: Press it to adjust/increase the function, such as adjust time, aroma
concentration, working days.
•DOWN: Press it to adjust/increase the function, such as adjust time,
aroma concentration, working days.

thenaturearoma.com
SET THE WORKING PERIODS:
The machine can be set for 5 groups different working periods, it can also set
different working days from Monday to Sunday according to different request.
(Such as working for Monday, Wednesday, Friday; Stop for Tuesday, Thursday,
Saturday)
•First time to press (MODE), the LCD display will show (EVENT 1 ON)
means it is the START TIME of first group. Then, press (SET) to do the
program setting, Press [UP/DOWN] to adjust the hours, minutes and
needed working days group.
•Second time to press (MODE), the LCD display will show (EVENT 1 OFF)
means the PAUSE TIME of first group. Then, press (SET) to do the
program setting. Press (UP/DOWN) to adjust hours, minutes.
•Third time to press (MODE), the LCD display will show (SCENT WORK
PAUSE) means the AROMA CONCENTRATION SETTING of first group.
Press (UP/DOWN) to adjust the aroma concentration. Every time you can
adjust 5% (such as 5%, 10%, 15%...), the maximum is 95%, the minimum
is 5%.
Notice
1. For example, 5% means it work for 10 seconds and stop for 190 seconds.
95% means it work for 190 seconds and stop for 10 seconds. Means
based on a period of 200 seconds totally for ON/OFF.
2. Long press MODE button back to Factory Settings (60%)
3. Press SET for 10s to lock/open the PCB system settings
TIP
If don't use the equipment for a long time, please clean the spray nozzle and
internal parts.
operation: add 95% alcohol to the empty oil bottle, set the machine to be 95% to
work for 10-15 minutes.
To clean the machine with 95% alcohol every two months.

thenaturearoma.com
TROUBLESHOOTING & MAINTENANCE
TROUBLES
ELIMINATION
METHODS
MAINTENANCE
NO LCD indication
Check the power supply
and the switch
Connect the power supply
again and turn it ON
NO atomization
Check the power supply;
check the pump working or
not; check the working
status (working time or
pause time)
Connect the power supply
again to check the pump
and set the program again
Small atomization amount
Check the atomizer if block
or not; check the pump
good or no
Clean the atomizer and
change the pump
Comes out liquid oil from
external atomization
connector
Check if the atomization
connector is loose or not
Check if the machine is
lean or not
Tighten the atomization
connector and make the
machine upright
Oil Leaking
Check if the oil bottle is
loose or not: Check if the
bottle seal is lost or not
Tighten the oil bottle and
bottle seal
OPERATION FOR ADDING AND CHANGING THE OIL
For the first time to the machine, please tighten the oil bottle before connecting
power supply, Set the working time and adjust the aroma concentration.
If need to add or change the oil, please cut down the power supply. Then open
the machine with the key rotate the empty oil anticlockwise to take out the bottle
to put the oil in again and finally clockwise rotate the bottle and make sure it is
tight. Then connect the power supply again.

thenaturearoma.com
WARRANTY
It is suitable for all the machines.
Within 12 months after purchase date, Warranty is offered for all qualified
machines. During warranty, we will offer repair services and the free parts.
The warranty card & purchase Invoice are needed if after service required.
Please do contact with us within warranty if any problems.
THE FOLLOWING IS NOT FOR FREE WARRANTY
SERVICE
• Damage & problems caused by Accidents & Fire.
• Not use properly and wrong operation.
• If repaired by not professional person and make some parts damaged.
• Damage during transportation.
• Without our warranty card.
• Without proper cleaning for a long time.
• Machines & Parts not from us.
• Machines not gotten from official channels.
• Send the machines back without permit from manufacturer.

thenaturearoma.com
EQUIPMENT COMPONENT INSTRUCTIONS
INSTALLATION METHOD

thenaturearoma.com
METHOD OF CHANGING ATOMIZING CORE
Step 1: Screw out the essential oil bottle, then pull out the pipe and take the
atomizing core out.
Step 2: Put the oil pipe into the opposite hole of the remarkable hole, then put the
new atomizing core inside the machine.
Dear Users:
1. Please read carefully before use and keep properly.
2. Please make sure the machine without any essential oil inside the bottle
during transportation, so that to protect the machine from getting damaged
and leaking.
3. Please make sure the machine upright, no leaking and not down; or may
damage the device and parts.
4. Please do not use the broken power wire and make sure the power supply
is suitable for the machine or may cause fire.
5. Please do not open the machine by yourself, if any problems, please
contact us promptly!

thenaturearoma.com
Table of contents
Popular Accessories manuals by other brands

Elko
Elko SmartSensor Leakage Wireless manual

IFM Electronic
IFM Electronic Efector 250 Series Brief instructions

Telldus
Telldus 15261 user manual

Infineon
Infineon TLE5501 Series user manual

Gaggenau
Gaggenau IK 36 251 Series operating instructions

elsner elektronik
elsner elektronik KNX B8-TH Installation and adjustment