NÜO PASS User manual

Installation manual
42106 | 42142
NÜO PASS

2

NÜO PASS Manual
Introduction Features
3
GENERAL FEATURES
NÜO PASS (Ref. no. 42106 and 42142)
--Combined biometrics reader with proximity.
--High resolution 500 dpi optical ngerprint sensor.
--Maximum security proximity reader for MIFARE Plus® cards
and MIFARE® DESFire® EV1, MIFARE® Classic and MIFARE
Ultralight® cards available on demand.
--Proximity card reader from a distance of 3 to 5 cm.
--Acoustic-light indicators to show when the credentials have
been granted or denied access, in addition to the reader operating
mode (ngerprint only, card only, ngerprint or card, etc.).
--Capacity for up to 9,500 users with ngerprints on card.
--Wear-resistant surface nish.
--Flush mounted for indoor use.
REGULATIONS
ISO/IEC 14443 A and B.
AES128 NIST FIPS PUB 197 MIFARE Plus® certicado de acuerdo a Common Criteria level EAL4+ .
NFC MIFARE® emulation compliant.
NFC MIFARE® emulation compilant.
EN 60950-1 2001 and A1: 2004.
EN 300 330-2 v1.3.1.

NÜO PASS Manual
Introduction Features
4
Technical Specications
TECHNICAL SPECIFICATIONS
NÜO PASS:
INPUT VOLTAGE 24 VDC (11 - 28 VDC)
MAXIMUM POWER 5 W
READING DISTANCE 3 - 5 cm
FINGERPRINT SENSOR TYPE Optical
SENSOR RESOLUTION 500 dpi
MAX. NO. FINGERPRINTS 9,500 ngerprints (1:1) - 1,000 (1:N)
COMMUNICATIONS BUS RS-485
INPUTS 1 Door sensor input
OUTPUTS 1 Output for lock control
24 vDC / (250 mA maximum)
ILLUMINATION
Colours according to status:
RED/WHITE: Terminal oine
DEGRADED RED/PINK: Terminal in enrolment mode
FLASHING BLUE: Terminal in rmware update mode.
BLUE: Terminal on standby / standard security
GREEN: Access granted / Unrestricted
RED: Access denied / Door blocked
WHITE: Reading ngerprint/card
FLASHING WHITE: Fingerprint enrolment
PURPLE: High security mode
PINK: Very high security mode
YELLOW/GREEN: Emergency
FLASHING YELLOW: Connected but not congured
AUDIO Dierentiated sound indicators for granted and denied access
and statuses.
OPERATING
TEMPERATURE -10 °C to 50 °C
READER DIMENSIONS 140 x 80 x 54 mm (height x width x depth)

NÜO PASS Manual
Introduction
5
Features Wiring
The NÜO PASS incorporates a male overhead connector.
NÜO PASS is supplied with a 3.5 metre piped cable with 4 wires (2 twisted pairs) and a female connector
at one end to correctly connect it.
The other end of the piped cable is connected to a single door controller or to the corresponding Wili
following the simple colour coding.
The built-in piped cable used to connect the reader has the following technical characteristics:
- Gauge: 0.22 mm
- Arrangement: 2 twisted pairs
- Resistance: <2 Ohms
A minimum distance of 12 cm must be maintained if installations are made with doors with 2 input/
output readers or with 2 readers that are very close together.
TYPE OF WIRING AND WIRING DISTANCE:
WIRING SPECIFICATIONS:
DISTANCE BETWEEN READERS:
The wiring distance from the reader and the single door controller or Wili should not
exceed 25 metres in length under any circumstances.
Orange
O/W
Green
-
A
B
+
BY B U S
G/W
3.5 metres of cable
NÜO PASS

NÜO PASS Manual
Installation
6
NÜO PASS Installation on built walls
1) Remove the front panel using the suction
cup provided. The panel will be easier to
remove if the suction cup is placed in a corner.
2) Unscrew the ush mount support.
3) Using a level, make a hole in the wall with
the dimensions detailed in the diagram. Pass
the connecting cable through and grout the
hole.
4) Insert the ush mount support and pass the
cable through one of the holes, then connect
the assembly.
128
50
68
Plaster
5) Tighten the screws, fastening the assembly
to the ush mount base.
6) Place the front panel.
128 x 68 x 50 mm
--INSTALLATION ON BUILT WALLS:
--STEPS PRIOR TO INSTALLATION:

NÜO PASS Manual
Installation
7
NÜO PASS Installation in plasterboard (thickness 10 - 25mm)
1) Follow the initial steps listed in page 6.
2) Make a hole in the plasterboard with the
dimensions detailed in the diagram.
3) Insert the ush mount support and pass the
cable through one of the holes, then secure it in
place in the plasterboard using the tabs.
128
68
4) Connect the cable to the assembly that was
removed beforehand.
5) Tighten the assembly (1) and place the front
panel (2).
128 x 68 mm
1 2
--INSTALLATION IN PLASTERBOARD (THICKNESS 10 - 25mm)

NÜO PASS Manual
Installation NÜO PASS
8
Installation on concrete walls
1) Follow the initial steps listed in page 6.
2) Make 4 holes at the distance marked for Fis-
cher 5mm wall plugs.
3) Secure the mounting box using the 4 Fischer
wall plugs and the screws supplied.
130
70
4) Connect the wiring pipe and pass the cable
through, connecting the equipment.
5) Tighten the screws and place the front
panel.
Distance between holes 130 x 70mm Mounting box: 42170
--INSTALLATION ON CONCRETE WALLS:

NÜO PASS Manual
Installation
9
NÜO PASS Installation in other environments
1) Follow the initial steps listed in page 6.
2) Make 4 M3 holes and another hole with the
dimensions detailed in the diagram, taking the
radii or chamfer dimensions into consideration.
3) Connect the cable to the equipment and
fasten it using screws.
58.7
(x4) Inserto S-M3
118.69
56.49
58.7
26.5
32.2
118.7
126
63
66
33
R18.5
45°
15.84
R18.5
15.84
62.2
4) Place the front panel.
Install the equipment on outdoor
or indoor surfaces that are free
from vibrations.
Units: mm
Machining on minimum thickness plate: 1.2 mm
--INSTALLATION IN OTHER ENVIRONMENTS:

NÜO PASS Manual
Installation
10
NÜO PASS Wiring
NÜO PASS readers can be directly connected to two types of devices depending on the architecture
of the installation:
--Connection to a Wili.
--Connection to a single door controller.
The connection to be made for both types of devices is exactly the same. The colour code must be
followed. For more detailed information, consult the equipment manuals referenced earlier.
READER WIRING:
Install and connect the reader before powering the system.
NÜO readers use the 24 VDC input voltage corresponding to the controller equipment to
which they are connected, the power sources of which are rigorously prepared for such
purpose.
These signals must be perfectly isolated in order to prevent damaging the equipment or
installation.
Orange
Orange/White
Green
RS-485-A
RS-485-B
+
24VDC
BY B U S
Green/White
0V / GND
COLOUR SIGNAL
GND (0V)
+24 VDC
RS-485 A
RS-485 B
Wire mesh


June 2018Version: 03MT:17173
Changes or modifications not expressly approved by the party responsible for compliance could
void the user's authority to operate the equipmentÿ
Note: This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates, uses
and can radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the interference by one or more of
the following measures:
—Reorient or relocate the receiving antenna.
—Increase the separation between the equipment and receiver.
—Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
—Consult the dealer or an experienced radio/TV technician for help.