4
––
Max Length to Panel
Length
AWG
200’ (60 m)
22
300’
20
500’
18
Common Cable Connections
Red
Power In
Black
Ground
Shield
Shield Ground
Brown*
Tamper Out
Green
Wiegand Data 0 / RS 485A
White
Wiegand Data 1 / RS 485B
Yellow*
Beeper Control
Blue*
Green LED Control
Orange*
Red LED Control
Current @ 12 V and 25 C
Avg. mA
Max. mA
110
160
Current for ET25 @ 12 V and 25 C
Avg. mA
Max. mA
140
190
Attach the Reader to the Wall plate
Align the reader so that the tabs of the base plate slide into
the slots on the wall plate and slide the reader into position.
Install Metal Wall Plate to Single Gang Box
Connect the wall plate to the single gang box using the provided #6 screws. Alternatively you can use the provided #4 screws in
the four outer holes for other installation requirements. Drywall installations will require molly bolts.
2
Wire the Cable to the Control Panel
1
*these wires are only used in
Wiegand readers.
Alternative for
situations
outside of a
single gang box
installation.
Standard Single
Gang Box
Installation
Questions? Scan our QR code or visit
www.isonas.com/support/installFAQ
PURE IP™ WIEGAND READER
QUICK INSTALLATION INSTRUCTIONS
MODELS: R-1-MCT-W, R-1-MCT-WK
3
*Patent Pending
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this
device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by WaveLynx could void
the user's authority to operate the equipment.
”This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause
interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR
d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage,
et (2) l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.
Install the Reader Screw
Install the #4-40 screw or pin-in-torx at the bottom of the
reader.
Test the Reader
Power the reader, the red light-bar will light, followed by a beep.
Present a valid credential to the reader and the light-bar will turn
green.
5
Screw or
pin-in-
torx
Tools Required:
Items Included:
1”(25mm), 1/8” drill bits
Reader, Backplate & Wall Plate
Phillips Screwdriver
(2) #6 Screws
T8 Security Torx Bit
(1) #4-40, (1) pin-in-to
(4) #4 Screws
KEYPAD CONFIGURATION
R-1-MCT-WK Wall Mount Keypad reader (13.56 MHz, 125kHz, BLE, backlit)
If you are using your R-1-MCT-WK Pure IP™reader with an ISONAS IP Bridge™please execute the
following steps to establish 26 bit Wiegand communication:
1. Power cycle the R-1 reader.
2. Within 1 minute from powering on the unit, enter:
* 8 8 8 8 9 9 9 9
The LED will turn green and the keypad will beep three times.
3. Within 5 seconds, enter the # followed by any three-digit facility code:
# ___ ___ ___
Note: Most sites will not have a site code already established. If there is no site code already
established, we recommend 0 0 1. Any three-digit code will work.
Example: # 0 0 1
The LED will turn green and the keypad will beep three times.
4. If you are using ISONAS Pure Access Cloud or Pure Access Manager, you must specify the
configuration for “External Keypad Site Code” located on Settings -> Credential page.
Pure Access only allows one site code per installation.
In this mode, the reader sends the PIN (packaged as a 26-bit Wiegand output with the fixed
facility code). We recommend PIN numbers to be a four-digit number between 1 and
32767.
The PIN should always be entered starting with * and end with #.
Example: * 1 2 3 4 #
Isonas Inc 4750 Walnut St. Suite 110 Boulder CO 80301 800-581-0083

Popular IP Access Controllers manuals by other brands

4U CHECK4U KWS manual

4U

4U CHECK4U KWS manual

Siemens SIDOOR ATD410W operating instructions

Siemens

Siemens SIDOOR ATD410W operating instructions

VIRDI AC-2100 Plus user guide

VIRDI

VIRDI AC-2100 Plus user guide

Chamberlain CAPXL user manual

Chamberlain

Chamberlain CAPXL user manual

Anviz CX2 user guide

Anviz

Anviz CX2 user guide

Eden SOLO Technical manual

Eden

Eden SOLO Technical manual

impro technologies HRB910 installation manual

impro technologies

impro technologies HRB910 installation manual

Sebury F1 manual

Sebury

Sebury F1 manual

Viking C-2000 Technical practice

Viking

Viking C-2000 Technical practice

IDTECK iPass IP-RFL200 Quick installation guide

IDTECK

IDTECK iPass IP-RFL200 Quick installation guide

Global electronics EclypX Installation & user manual

Global electronics

Global electronics EclypX Installation & user manual

Ness VIRDI AC-1000RF installation guide

Ness

Ness VIRDI AC-1000RF installation guide

CAMDEN WC13PS Series installation instructions

CAMDEN

CAMDEN WC13PS Series installation instructions

CDVI DGLIWLC installation manual

CDVI

CDVI DGLIWLC installation manual

Axis 2N Access Unit Configuration manual

Axis

Axis 2N Access Unit Configuration manual

ievo ultimate reference guide

ievo

ievo ultimate reference guide

Integra BCR-SD G2 Installation and service manual

Integra

Integra BCR-SD G2 Installation and service manual

Viking RAD-1A Application note

Viking

Viking RAD-1A Application note

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.