PDQ 85001 User manual

This manual suits for next models

1

Popular IP Access Controllers manuals by other brands

Ava bqt miPASS BT510 installation guide

Ava

Ava bqt miPASS BT510 installation guide

ZKTeco SpeedFace-V5L user manual

ZKTeco

ZKTeco SpeedFace-V5L user manual

2N Access Unit Configuration manual

2N

2N Access Unit Configuration manual

Kedacom KSCA120 Series quick start guide

Kedacom

Kedacom KSCA120 Series quick start guide

H3C WX2880X installation guide

H3C

H3C WX2880X installation guide

G4S S870-EX Installation and user instructions

G4S

G4S S870-EX Installation and user instructions

PRASTEL M2000PE manual

PRASTEL

PRASTEL M2000PE manual

Allegion interflex IF-281 Cylinder manual

Allegion

Allegion interflex IF-281 Cylinder manual

TECOM TS1067E manual

TECOM

TECOM TS1067E manual

Fermax Memokey 100C Installer manual

Fermax

Fermax Memokey 100C Installer manual

Fermax CITYLINE MEMOKEY User& installer's manual

Fermax

Fermax CITYLINE MEMOKEY User& installer's manual

Civintec CV9601T-T-1F installation manual

Civintec

Civintec CV9601T-T-1F installation manual

BioMax N-X90W user manual

BioMax

BioMax N-X90W user manual

ZKTeco OP-200 quick start guide

ZKTeco

ZKTeco OP-200 quick start guide

FingerTec s-Kadex user guide

FingerTec

FingerTec s-Kadex user guide

H3C WX5002ACCESSCONTROLLER installation manual

H3C

H3C WX5002ACCESSCONTROLLER installation manual

Conrad Electronic KeyMatic CAC operating instructions

Conrad Electronic

Conrad Electronic KeyMatic CAC operating instructions

IDTECK Star 100R manual

IDTECK

IDTECK Star 100R manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Operating Voltage 12VDC,24VDC,12/24VDC
Voltage Tolerance ±15%
Current Draw 0.25A/12VDC
0.15A/24VDC
Operating Temperature 14 – 110 degrees F
Humidity 0-95%
For PDQ GR1 and GR2 Cylindrical
Locks
Faceplate
Door Stop
Latch Opening
Base
Cable
2 x M4x0.7 Screw(s)
4 x M5x0.8 Screw(s)
2 x 1-1/4 Wood Screw(s)
2 x M4x0.7 Nut(s)
2 x Butt Splice
Connector(s)
2 x Support Bracket(s)
Included Hardware Installation Instructions
1. Verify that the strike is in the proper mode of operation
(Fail Secure/ Fail Safe). Refer to page 3
2. Prepare frame using the appropriate template for your
frame type. Refer to page 2
3. Connect the strike to power source. Refer to page 3
4. Install the strike unit in jamb cutout using the hardware
provided. Refer to page 2
1
85101
REV 0
6/30/11
ANSI Metal Jamb Installations
Aluminum Jamb Installations
2
85101
REV 0
6/30/11
(2) M4x0.7
(4) M5x0.8
(2) M4x0.7 Nut
(2) Support
(4) M5x0.8
Fail Secure
Apply Power to Open
Fail Safe
Apply Power to Lock
Changing Fail-Safe / Fail-Secure
Strike is shipped from factory in fail-secure configuration. If fail-safe configuration is desired, remove
screw from hole #1 as shown in above diagram and loosen screw #2. Slide screw #2 to opposite end of
the slot and tighten. Install screw #1 into hole labeled fail safe.
Wiring Diagram
Black Black
Red Red
Red
Control Device
(e.g. Reader)
Power
Supply
12vDC/24vDC
Single Voltage (12v or 24v)
12vDC
24vDC
Dual Voltage (12v or 24v)
Black
Black Black
Red Red
Red
Black
Connect wires in Parallel for the 12vDC operation.
N.C. Contact or Access Relay for “Fail-safe” setting
N.O. Contact of Access Relay for “Fail-secure” setting
3
85101
REV 0
6/30/11
Connect wires in Series for the 24vDC operation.