Nabco GT1175 U-19 Specification sheet

1 of 6
GT1175 U-19 Electric Lock Retrot Kit Quick Setup Parts Guide
P/N 15-12499-031 Rev 12-19-14
Nabco Entrances Inc. S82 W18717 Gemini Drive Muskego, Wisconsin 53150
Phone: (877) 622-2694 Fax: (888) 679-3319 www.nabcoentrances.com
This document is meant to serve as a Quick Set-Up Guide only.
Installaon manuals referenced below should be downloaded from the NABCO Website and reviewed for complete installaon instrucons.
Table of Contents
SECTION 1: RETROFIT THE BELT CLIP 3
SECTION 2: INSTALL THE ELECTRIC LOCK 4
SECTION 3: CHANGE HANDING OF SLIDE DOOR 4
SECTION 4: U19 WITH FAIL SECURE OR FAIL SAFE ELECTRIC LOCK 5
SERVICE PARTS: U-19 ELECTRIC LOCK RETROFIT KIT 6
Associated Manuals Part Numbers: ”1175 Electrical Installation Manual U19 & Earlier” Rev 5-18-04 (P/N 15-10596)
• Turn OFF all power to the Automatic Door if a Safety System is not working.
• Instruct the Owner to keep all power turned OFF until corrective action can be achieved
by a NABCO trained technician. Failure to follow these practices may result in serious
consequences.
• NEVER leave a Door operating without all Safety detection systems operational.
WARNING

THIS PAGE IS INTENTIONALLY LEFT BLANK

3 of 6
www.NabcoEntrances.com GT1175U-19ElectricLockRetrotKitQuickSetupPartsGuide
Rev12-19-14 P/N15-12499-031
SECTION 1: Retrot the Belt Clip
Note: Electric Locks can not prevent Breakout. If prevenng Breakout is deemed necessary, panic hardware must be ed to
the Door Panels.
Remove (2) 1/4-20 x 1 inch Hex Head screws used to secure the Belt Clip to the Belt Bracket. Save the spacers, screws and
a. Ensure the Belt Clip stays intact with the Belt, so the Belt does not lose Belt Tension.
Figure 1 and Figure 2.
a. If necessary rotate the Latch so the Flat Side of Latch faces the Terminal Strip located on the Lock Assembly.
DN 0743
Flat Side of Latch
Terminal Strip
Terminal Strip
Flat Side of Latch
Figure 1 Proper Latch Orientation
Secure the Belt Bracket to the Belt Clip with (2) 1/4-20 x 1 inch Hex Head screws, lock washers, and spacers that were saved
a. Figure 2.
Belt Clip Bo om
Terminal Strip
Belt Bracket Relay
Belt Clip Top
Terminal Strip
Belt Bracket
Relay
DN 0534
SINGLE SLIDE DOOR; RHFS, LHFO
BIPART SLIDE DOOR
Motor/Operator U-19 & Earlier
Motor/Operator
U-19 & Earlier
Motor/Operator U-19 & Earlier
Belt Clip Top
Belt Clip Top
11 11/16
11 11/16
8 5/16
SINGLE SLIDE DOOR; LHFS, RHFO
Figure 2 Belt Clip Location in Full Close Position

4 of 6
GT1175 U-19 Electric Lock Retrot Kit Quick Setup Parts Guide www.NabcoEntrances.com
P/N 15-12499-031 Rev 12-19-14
SECTION 2: Install the Electric Lock
Insert (2) 3/8 -16 x 3/4 inch T-Bolts into the Channel located inside Header and turn clockwise so they do not fall out.
DN 0738
Insert T-Bolt
into Channel
Turn T-Bolt Clockwise
to Lock into Channel
Figure 3 Insert Socket Head Cap Screws into Channel
Place the Electric Lock over the (2) 3/8-16 x 3/4 inch T-Bolts.
a. Ensure the Terminal Strip is facing the Pivot side of Slide Door.
Loosely secure the Electric Lock to the T-Bolts with (2) 3/8-16 Whizlock nuts.
see Figure 4.
a. Ensure there is a slight gap between the Strike Wall and Flat of Latch.
DN 0642
Strike Wall
Slight Gap
(Between Strike Wall and Flat of
Latch in Full Close Posi on)
Latch
Strike
Figure 4 Ensure Terminal Strip is Facing Pivot Side of Slide Door
Tighten (2) 3/8-16 Whizlock nuts to secure the Electric Lock to the Channel.
4.
SECTION 3: Change Handing of Slide Door
Note: Handing of the Slide Door is only necessary if the Slide Door: Opens when it should Close; or Closes when it should Open.
Obtain the Handing Harness provided within the Parts Bag.
Go to the Motor Harness that is connected to the Motor and the U-19 Microprocessor Control.
Separate the Motor Harness to connect the Handing Harness between the connectors.
Motor Connector (6 pin)
Power Connector (4 pin)
Size: 5.2 x 20mm
Rang: 125V, 5A
Fuse Inside
No.
COLORSYMBOLNO.
12
11
10
9
8
7
6
5
4
3
2
1
OUT -
OUT +
BA
SQ
62
M1
M0
H
6 B
61
7
9DC12V
Gray
Violet
Blue
Yellow
Orange
Orange
Orange
Green
White
Black
Red
Brown
COLORNO.
6
5
4
3
2
1
Yellow
Black
Blue
Brown
Orange
Red
USE
Encoder B Phase
Encoder Ground
Motor U Phase
Encoder A Phase
Encoder 12 VDC
Motor V Phase
USECOLORNO.
4
3
2
1
Black
White
Not Used
115 VAC Hot
115 VAC Common
Not Used
WARNING
type and rang.
with a fuse of the same
against fire, replace only
For connued protecon
CAUTION
DN 0749
Handing Harness
Motor Harness & Plug
Microprocessor Control
Motor
Figure 5 Change Handing of Slide Door

5 of 6
www.NabcoEntrances.com GT1175U-19ElectricLockRetrotKitQuickSetupPartsGuide
Rev12-19-14 P/N15-12499-031
SECTION 4: U19 with Fail Secure or Fail Safe Electric Lock
Note: Electric Lock only works in One Way mode or Night Mode.
DN 0694
VIO
GRY
WHT
BLK
NOTES:
1. UNDER "SPECIAL FUNCTIONS" SET "AUX. OUTPUT" TO "0".
2. SET "OUTPUT TIMER" TO "3".
TO 120VAC
LOCK
U-SERIES CONTROL
(U19 OR EARLIER)
RELAY
Wire Nut
10-3125
BROWN 60"
VIOLET 60"
OUT+
(VIOLET)
OUT-
(GRAY)
7 (RED)
9DC12V
(BROWN)
GREY 10"
VIOLET 10"
HANDING HARNESS
(Used only when Necessary
)
PT. NO. 11-9208
HARNESS
MOTOR
1
6
110V
HANDY TERMINAL (6P)
SENSOR (12P)
1.Please adjust this operator as per instrucon manual.
2.Turn the power off, before opening the box.
3.Don't open this box except for replacing fuse.
Otherwise, the warranty will be terminated.
4.Repair of this unit except by Lanson Industries, Inc.
may cause soware and hardware malfuncon.
USE
USE [SLIDER/SWINGER]
For connued protecon
against fire, replace only
with same type and rang
of fuse.
WARNING
FUSE INSIDE
RATING:125V,4A
SIZE:5.2 x 20mm
COLOR
BROWN
RED
BLACK
WHITE
GREEN
ORANGE
ORANGE
ORANGE
YELLOW
BLUE
VIOLET
GRAY
7
61
6B
9DC12V
SYMBOL
H
M0
M1
62
BA
OUT +
OUT -
SQ
1
2
3
4
NO.
5
6
7
8
9
10
11
12
POWER SOURCE (4P)
OPERATOR (6P)
EMPTY
115VAC HOT
EMPTY
115VAC COMMONWHITE
BLACK
1
2
3
4
COLORNO.
MOTOR V PHASE
ENCODER 12VDC
ENCODER A PHASE
MOTOR U PHASE
ENCODER GND
ENCODER B PHASE
ORANGE
RED
BROWN
YELLOW
COLOR
BLUE
BLACK
1
2
3
4
5
6
NO.
GYRO TECH
ENTRANCES
LANSON INDUSTRIES INC.
CAUTION
No.
MICROPROCESSOR CONTROLLER
PT. NO. 24-8901
& PLUG
MOTOR
BROWN 60"
VIOLET 60"
GREY 10"
VIOLET 10"
FAIL SAFE RELAY WIRING
P/N 24-14594-02
BROWN 60"
VIOLET 60"
GREY 10"
VIOLET 10"
FAIL SECURE RELAY WIRING
P/N 24-14594-01

6 of 6
GT1175 U-19 Electric Lock Retrot Kit Quick Setup Parts Guide www.NabcoEntrances.com
P/N 15-12499-031 Rev 12-19-14
Header
Item Part Finish/Sizes/Notes Descripon
111-9208 HARNESS, HANDING, U-19 MICROPROCESSOR
214-14592 T-BOLT, 3/8”-16 X .75 LG
322-10522-03 Fail Secure
22-10522-04 Fail Safe
424-14594-01 Fail Secure
24-14594-02 Fail Safe
524-0021-21
614-12104-10
714-11870 SPACER, BELT CLIP, 1175
824-11493 CLIP, BELT
924-0019-05 1/4” EXTERNAL STAR WASHER
10 24-0014-01 HHCS, 1/4-20 X 1”, ZN
11 24-0014-15 HHCS, 1/4-20 X 3/4, ZN
DN 0687
*Sold in Parts Bag; P/N 12-10599-01 Fail Secure
Sold in Parts Bag; P/N 12-10599-02 Fail Safe
**
1
2
3
4
5
6
7
8
910
11
Front Back
SERVICE PARTS: U-19 ELECTRIC LOCK RETROFIT KIT
P/N 21- Fail Secure
P/N 21-11658-04 Fail Safe
1
2
3
4
5
6
7
8
9
10
11
Table of contents
Other Nabco Lock manuals
Popular Lock manuals by other brands

BURG WATCHER
BURG WATCHER TSE 3004 Operating instruction

Assa Abloy
Assa Abloy Sargent Passport 1000 Series installation instructions

Vemus
Vemus Kilitronik MiniK 10p operating manual

COMPX
COMPX Stock Locks C8051 Dimensional drawing

Yale
Yale 5400LN SERIES installation instructions

Sargent and Greenleaf
Sargent and Greenleaf Comptronic 6124 Set up and operation guide