Naggura N'RUN Series User manual

N’RUN series 2-3-4-5 models, with accessories
N’RUN __ line
N’RUN line
VERSION 1.0
Instruction Manual
EN

Instruction
Manual
2
N’RUN
N’RUN series 2-3-4-5 models, with accessories
Instruction Manual
Table of contents
1. Introduction
2. Use of the manual
3. Warranty
4. Liability
5. EC Declaration of conformity
6. Safety instructions
7. Product Dimensions
8. Operation
Wheel block/unblocking system
Gas piston levers
Peripherial switch
Handlebar support
Paper roll holder
Nose gap
Twinli armrests
Folding widening supports
Safety lock
Switches for lumbar flexion and Heating
Lever for back section
9. Maintenance and cleaning
10. Troubleshooting
11. Service

Instruction
Manual
3
N’RUN
CONGRATULATIONS! You took NAGGURA home!
Thank you for having acquired a NAGGURA product and for the trust shown in us.
We are sure that this treatment table will turn into the pillar of your work and will more than
fulfil your most demanding work requirements. NAGGURA’s experts are in the lead of a project
created with great devotion. Every single detail has been cared to join technology, performan-
ce and design altogether in a single table. Our aim is designing and manufacturing INTUITIVE,
DYNAMIC and HI-TECH tables of a DARING and UNIQUE design.
Thanks for your choice and start enjoying the NAGGURA experience.
1. Introduction

Instruction
Manual
4
N’RUN
Please make sure that this instructions manual is always accessible to the personnel involved with the use of this equipment.
The manual describes the correct use of the dierent models and types.
Some texts and/or illustrations are not relevant to your Naggura couch since it depends on your product choice at the purchase
time.
2. Use of the Manual
The warranty period for your Naggura N’RUN is 2 years for all the components of the couch, from its date of purchase.
The above-mentioned warranty is not applicable in the following cases:
a. In the event of improper use of the couch;
b. In the event of non-observance of the precautions stated in this instruction manual;
c. If repair and maintenance are carried out by non-qualified service personnel who are unauthorized by the manufacturer.
d. the device is not serviced regularly in accordance with the instructions (maintenance interval: every 2 years)
e. the electrical installation meets the legal requirements
The warranty only covers materials and production defects.
3. Warranty
The manufacturer cannot be held responsible for any consequences incurred by the user, the patient or by the couch itself as a
result of e.g.
a. A wrong diagnosis;
b. Incorrect use of the couch or any of its accessories;
c. The wrong interpretation or non-observance of this user manual;
d. A lack of maintenance of the couch;
e. Or maintenance works of the couch and/or repairs performed by persons unauthorized to do so by the manufacturer.
Aer a period of 10 (ten) years aer introduction of the couch (or any of its accessories), the manufacturer can no longer be held
responsible for any flaws in the couch or its accessories and he will no longer be obliged to supply any spare parts or accessories.
4. Liability
The expected lifespan of the Naggura bed is 10 years. This counts from the production date.
Naggura will try to provide spare parts during this period, as far as possible.
Expected lifespan

Instruction
Manual
5
N’RUN
Naggura products are produced and marked in conformity with the directives hereby stated:
Low voltage: 2014/35/CE
Electromagnetic compatibility: 2014/30/CE
Classification (according to the Annex of MDR): class I, rule 1
Conformity assessment route: Chapters I and III of Annex IX of MDR
These products are manufactured according the essential requirements established in the European Medical Device Directive:
IEC 60601-1-2:2014 (fourth edition), IEC 60601-1:2005
COR1: 2006, COR2:2007, AMD1:2012 (or IEC 60601-1:2012 reprint), IEC 60601-1-6:2010, AMD1:2013 for use in conjunction with IEC
62366:2007, AMD1:2014 and IEC 60601-1:2005,COR1:2006, COR2:2007,AMD1:2012
The N’RUN line has a guarantee of 2 years in all parts. The manufacturer will not be held responsible for the results of maintenance
or repairs performed by unauthorised persons. For further information on guarantee terms, please contact your distributor.
5. EC Declaration of conformity
Naggura treatment tables are only meant to be used by professional personnel in Physiotherapy, rehabilitation, examination and
massage field.
It is the responsibility of the owner to ensure that training is given to all operators and third parties (like for example cleaning per-
sonnel) on safe use of the treatment table, and that they have read and understood all the operating and safety instructions.
Only trained operators may use the treatment bed. Please keep the manual in a place where it is easily accessible to all users, and
make it an important part of your employee training program.
6. Safety instructions
Responsibility of the owner
- Place the table in a space with free access from the 4 sides. Do not place the table against the wall or against any obstacles.
- Do not use the table in a high-humidity environment
- Check if the mains voltage and frequency are in accordance with the information on the typeshield. If not, contact your supplier
before connecting the device.
- Make sure that the unit is correctly plugged into an earth intake, following the local and national requirements and standards.
- Make sure that the mains cable is positioned in such a way that it cannot get stuck between the mechanism.
- Especially pay attention that the mains cable does not get pinched under the feet of the table, for example aer the tables has
been moved on its wheels.
- If the table gets wet accidentally, unplug the table immediately.
Safety on installation and electricity

Instruction
Manual
6
N’RUN
- Don’t let anybody, except the operator and the patient, in the treatment room
- The bed may not be used for patient transport.
- Never leave the bed on its wheels during treatment.
- Do not exceed the maximum load of the table (see typeshield)
- Place the table on a stable and horizontal surface.
- Guide the backrest section with the other hand when adjusting the backrest by gas levers.
- Make sure that all persons, hands, or limbs are always clear from the mechanism of the bed especially when the table or parts of
the table move downwards (picture below)
Safety during treatments
- Put the safety lock in o-position (green LED must be o) and remove the safety key.
- Do not leave anybody unattended alone near the table
Safety instructions
Safety before or aer the treatment
- Put the safety lock in o-position and remove the safety key (green LED must be o)
- Pull out the mains plug
- Do not move into the elevating mechanism (picture below)
Safety when cleaning the bed or the therapy room

Instruction
Manual
7
N’RUN
N’RUN 2L N’RUN 2W
N’RUN 3 N’RUN 4
N’RUN 5
7. Product dimensions

Instruction
Manual
8
N’RUN
Pack dimensions (cm)
Handling and transport
Do not li from the long sides

Instruction
Manual
9
N’RUN
cm
Product dimensions in movement (cm) Power cord lenght (cm)
Voltage and frequency input shall be AC 100-120, 50/60Hz or 220-240V, 50/60Hz. Plug the bed on the power supply properly as
shown below:
8. Operation
Power input

Instruction
Manual
10
N’RUN
1. Wheel block/unblocking
system
2. Gas piston levers
3. Peripheral switch
4. Handlebar support
(NRUN2L, 2W and 3)
5. Paper roll holder
6. Breather hole
7. Twinli armrests
(NRUN4 and 5)
8. Folding widening supports
(NRUN 2W)
9. Safety Lock
10. Switches for lumbar flexion
and Heating
11. Lever for back section
Optional
Operation of N’Run

Instruction
Manual
11
N’RUN
3
The height of the table can be adjusted from the 4 sides of the table thanks to a very intuitive peripheral switch. The mechanism on
both sides consists of 2 grey long overhanging bars which are fully integrated in the base making the design simply beautiful. When
the physiotherapist presses the bar with his foot, the table goes up. If the physiotherapist pulls on the same bar, the table goes
down. In the front and rear part of the table, the height motion is operated by means of 2 foot switches for both up and down mo-
vements respectively. The arrows show the sense of the movement (up or down). In the case of N’RUN3 and N’RUN5 (2 engines), the
peripheral switch controls the height, while the second motor movements are controlled by 2 buttons placed one side of the table.
Operation
Peripheral Switch

Instruction
Manual
12
N’RUN
10
10
Operation
Specifications
Product size 202 (+/- 23 cm with movement) x 68 x 56 / 92 cm
Package size 206 x 74 x 65 cm
Highest position 92 cm
Lowest position 56 cm
Net weight 132 / 148 Kg
Gross weight 142 / 158 Kg
Power AC 100 - 120V, 50/60Hz · AC 220 - 240V, 50/60Hz
Max power 300W
Environment temperature 0ºC - +40ºC
Relative humidity 30% - 90%
Max weight supported 200Kg
Section motors
If your table is equipped with more than one motor to adjust one of the sections, is possible to adjust them by the push button
box placed at both sides of the table. If a handcontroller is included, the motors can also be adjusted by the buttons on the
handcontroller.
N’RUN3 and N’RUN5 button panel for
controlling middle section engine.
Switches for lumbar flexion and heating
The tables N’RUN3 and N’RUN5 may feature the optional heating. This feature is controlled by the side button panel in the top of
the bed, and it allows to switch on or o the heating system. You can check the state of the heating system by looking at the LED
indicator. Next to the heating option, you can find the controls of the middle section motor.
Optional

Instruction
Manual
13
N’RUN
7
9
Operation
Twinli Armrests
If your table is equipped with a head section with arms support (N’RUN4 or N’RUN5), you can adjust them as it is shown in the pic-
tures below. Press the lever on the side, and adjust the exact height you need the armrests to be. Both arms will eortlessly move at
the same time to the desired position.
Safety lock
The table can be locked or unlocked using the key on the base. If the key switched to ON-position (in vertical position, pointed
towards the LED), the LED behind the safety lock lights up, and you hear a “beep”. Now the table and all its functions are
unlocked and ready to use.
If the key is in OFF-position (horizontal position),
the table is locked and all the electrical systems
are disabled.
The safety-key can only be removed when the
safety lock is in OFF-position.
*(Only available for Germany)
The table can only released from its standby mode when the peripheral
switch or the switch for lumbar flexion is pushed 2-times. This is called the
double-tip system.
Once it is released, the user can adjust all settings within a period of approx.
5 sec. Aer that, the system goes automatically into standby mode again.
LED to indicate if the
table is switched ON
OFF
ON
Integrated safety system with automatic standby mode*

Instruction
Manual
14
N’RUN
9. Maintenance and cleaning
Cleaning the chassis and metal frame:
Clean the table with a clean, so and dry cloth.
For persisting stains, use a white cloth, damp it with clear water and a domestic household cleaner FREE of alcohol.
Cleaning the cushions:
The Naggura tables have a high quality Spradling vinyl protected by Permablok, against stains and abrasion.
The vinyl should be cleaned periodically in orde to maintain its appearance and prevent build-up of dirt and contaminants.
Any stains should be removed immediately.
Daily cleaning:
Clean the entire surface using a mixture of 1:9 liquid soap (neutral PH) and water. Do not use soap or cleaning solutions that
contain alcohol, ketones, xylene, acetates or solvents.
- Massage oils should be removed with a PH-neutral soap immediately.
Cleaning of tougher stains:
Use the original Naggura Cuirnet high-performance cleaner in a dilution of 1:9 Cuirnet and water.
If the stain cannot be removed, the cuirnet cleaner maybe be used undiluted.
-Aer the cleaning, always rinse with clear water and dry.
-NEVER use the Naggura Cuirnet cleaner for the metal frame of the table.
Disinfection:
The list of recommended disinfectants, refers to the performance of Permablok in specific tests, conducted under laboratory
conditions. Results may vary under actual conditions.
Asepticare TB + II
Antifect (in 0,5% dilution)
Caviwipes XL Packed
Cleanisept Wipes
Clorox Healthcare bleach germicidal wipes
Desomed rapid
FD 366
Hydrogen Peroxide Disinfectant Wipes
Instrunet Anionsurf
Lysol Foaming disinfectant cleaner
Microzid
Oxivir TB Wipes
Oxycide Diluted 3 oz/gl in water
PDI Sani-cloth bleach wipes
Sanicloth AF 3
Sodium Hypochlorite disinfectant bleach cleaner (dilution 1:10 of bleach and water)
Surfanious Premium (in 0,25% dilution)
Surfa’Safe Premium (in 0,25% dilution)
Super-sani-cloth
Virex II 256 (1:256 dilution)
Virox 5 Rtu
Wet wipe
Wex Cide 128 (1:128 dilution)
Aer the surface has been disinfected or cleaned, rinse the surface with clean water and dry.
Maintenance
Naggura tables have been designed for an intensive use during long time thanks to its stability, reliability and durability.
However, we advise to keep the table in perfect conditions and make a correct use of it. Unplug the table if you will not use it
for a long period of time.
Environment information
If this symbol appears on electrical products or on its packaging, this means that they must be recycled properly. Please en-
sure that you are well informed of the local rules and regulations regarding to the removal of equipment and accessories.

Instruction
Manual
15
N’RUN
10. Troubeshooting
The top sections cannot be adjusted
The supporting gas springs might “stick” if the couch has not been used for a long time
• In such a case, push the corresponding lever with your hand, wait for a few seconds and pull the table section upwards with
the other hand.
The electric adjustments do not work
• Check if the keyswitch is on.
• Check if the green LED lights up.
• Check the power cable for any damage.
• Check all the plugs and connections.
Persisting problems
If the problem persists, contact your local distributor and provide the serial number and the model of the table, or a picture of
the typeshield.
This can be found on the typeshield, located at the backside of the table, inside the top frame.
Only a technician authorized by Naggura is allowed to perform any kind of repairs on the bed.
If your technical sta is allowed by Naggura to repair the bed, naggura can provide the necessary instructions and spare
parts lists.
Please contact your local Naggura distributor for more information.
11. Service
Serial number

Instruction
Manual
16
N’RUN
Our products are subject to
continuous technical improvements.
Naggura reserves the rightto
change ormodify the product and
contents without prior notice.

www.naggura.com
Pol. Ind. La Valldan
Camí de Garreta, 92
08600 Berga
Barcelona - Spain
T. +34 93 824 90 20
E. info@naggura.com
Other manuals for N'RUN Series
2
Table of contents
Other Naggura Medical Equipment manuals