8. Settings
Wheels
Gas piston levers
Peripheral Foot switch
Handlebar Support
Paper roll holder
Breather hole
Armrests
Heating
9. Maintenance
10. Troubleshooting
N’RUN

Introduction
CONGRATULATIONS! You took NAGGURA home!
Thank you for having acquired a NAGGURA product and for the trust shown in us.
We are sure that this treatment table will turn into the pillar of your work and will
more than fulfil your most demanding work requirements. NAGGURA’s experts are in
the lead of a project created with great devotion. Every single detail has been cared
to join technology, performance and design altogether in a single table. Our aim is
designing and manufacturing INTUITIVE, DYNAMIC and HI-TECH tables of a DARING
and UNIQUE design.
Thanks for your choice and start enjoying the NAGGURA experience.
2
Instruction
Manual
N’RUN

3
Instruction
Manual
Use of the manual
Please make sure that this instructions manual is always accessible to the personnel involved with the use of this equipment.
The manual describes the correct use of the dierent models and types.
Some texts and/or illustrations are not relevant to your Naggura couch since it depends on your product choice at the purchase time.
Warranty
The warranty period for your Naggura N’RUN is 3 years for all the components of the couch, from its date of purchase.
The above-mentioned warranty is not applicable in the following cases:
a. In the event of improper use of the couch;
b. In the event of non-observance of the precautions stated in this instruction manual;
c. If repair and maintenance are carried out by non-qualified service personnel who are unauthorized by the manufacturer.
Liability
The manufacturer cannot be held responsible for any consequences incurred by the user, the patient or by the couch itself as a result of e.g.
a. A wrong diagnosis;
b. Incorrect use of the couch or any of its accessories;
c. The wrong interpretation or non-observance of this user manual;
d. A lack of maintenance of the couch;
e. Or maintenance works of the couch and/or repairs performed by persons unauthorized to do so by the manufacturer.
After a period of 10 (ten) years after introduction of the couch (or any of its accessories), the manufacturer can no longer be held responsible for any
flaws in the couch or its accessories and he will no longer be obliged to supply any spare parts or accessories.
N’RUN

4
Instruction
Manual
EC Declaration of conformity
Naggura products are produced and marked in conformity with the directives hereby stated:
Low voltage: 2006/95/CE
Electromagnetic compatibility: 2004/108/CE
These products are manufactured according the essential requirements established in the European Medical Devices Directive 93/42/EEC.
The N'RUN line has a guarantee of 2 years. The manufacturer will not be held responsible for the results of maintenance or repairs performed by
unauthorised persons. For further information on guarantee terms, please contact your distributor.
Warnings and general instructions
1. When you receive the order, check first whether the product has been damaged during transport. Report your dealer immediately about any
damage, defect or non-conformity with the order received.
2. Keep the packaging and store it during the first 20 days.
3. Read this manual carefully before using the equipment.
4. The maximum loading weight is 300 kg.
5. Do not place the hands in the moving parts of the treatment table when performing any electrical adjustment. The motor has a safety system with
brake which stops exerting strength when an obstacle is found. However, this safety device will not prevent the weight of the table section from going
down.
6. Guide the backrest section with the other hand when adjusting the backrest by gas levers.
7. Make sure that the unit is correctly plugged to an earth intake following the local and national electrical requirements and standards.
8. Although the treatment couch is equipped with wheels, it cannot be used for the transport of patients.
9. Keep the table out of high-humidity environments.
10. If the table gets wet accidentally, unplug the table immediately.
11. Naggura treatment tables are only meant to be used by professional personnel in physiotherapy, rehabilitation and massage fields. Avoid any use of
the equipment by unauthorised non-skilled personnel.
12. Place the table in a space with free access form the 4 sides. Do not place the table against the wall or against any obstacles.
13. Do not leave children unattended alone near the table.
14. Change the bed cover or protecting paper after each patient in order to guarantee the hygiene of the treatment.
15. Whenever it is necessary to lift the bed, DO NOT take it by the upholstered section. You must take it by the structure, as it is shown in the pictures
below.
N’RUN

5
Instruction
Manual
Product dimensions in movement (cm)
Pack dimensions (cm)
Handling and transport
Power cord lenght (cm)
300
control
box
215 80
80 N’RUN–– line
www.naggura.com
Madein EU
N’RUN
––
line
PHYSIOTHERAPY
TABLE
220
N’RUN
NO
21 &
1
2
1
5
8
9
10
67
2
3
4

6
2
9
1
1
3
3
10
3
4
5
Essential Settings
1. Wheel block./
unblocking system
2. Gas piston levers
3. Peripheral switch
4. Handlebar support
5. Paper roll holder
6. Folding armrest
7. Breather hole
8. Armrests
9. Heating
10. Safety Lock
Optional
6
57
1
1
2
Only N’RUN303
Instruction
Manual
7
N’RUN
2

Essential Settings
7
Instinctive handling with easy access from the 4 sides of the table. The mechanism in each side of the table consists of 2 bars fully
integrated in the base making it simply beautiful. In the front and rear part of the table, the height motion is operated by means of 2 foot
switches for both up and down movements respectively. In the tables equipped with 2 or 3 engines, the peripheral foot switch controls
the height while the other motions are controlled by a push button box placed at both sides of the table.
Peripheral switch
3
3
3
3
Instruction
Manual
3
N’RUN

8
Instruction
Manual
If your table is equipped with a head section with arms support (optional), you can adjust them as it is shown in the pictures below.
Unscrew the fixing knob to loosen the arm-blocking mechanism, slide the arm support down the bar to its place and tighten the knob
again to block it.
Armrests (only 304, 308)
Essential Settings
8
Optional
N’RUN

9
Instruction
Manual
Heating
Essential Settings
9
Safety Lock 10
Optional
1 2 3
1. COMFORT option o
2. Comfort option on, with lower temperature level selected
(approx. 35 oC, green light on).
3. Comfort option on, with higher temperature level selected
(approx. 38 oC, orange light on).
For security reasons the Comfort mode switches o
automatically after 90 minutes.
The tables may feature the optional Comfort mode. It allows for a more comfortable
and relaxing experience when using the table.
The operating personnel must control the patient's state while operating the table with the
Comfort mode on.
N’RUN
if you want, you are able to block or unblock the Naggura table by using the Safety Lock system using the wheel.

10
Instruction
Manual
Maintenance
Cleaning
Clean the table frame using a damp white cloth, clear water and a domestic free-of-alcohol household cleaner. To clean
Spradling Permablock® upholstery, mix clear water with a mild soap, soak in water and remove excess of water. Next, rinse
with clear water and dry. Clean only in one direction. Before using any specific product, read the Spradling Care and
Cleaning guide to get more complete information. See the demo video in the QR symbol.
·Important: Lacquers, strong cleaners, xylene-based solutions, acetone or MEK cause immediate damage and contribute to the deterioration of
the material. The use of such cleaners is at the owner’s risk.
Maintenance
Naggura tables have been designed for an intensive use during long time thanks to its stability, reliability and durability.
However, we advise to keep the table in perfect conditions and make a correct use of it. Unplug the table if you will not use it
for a long period of time.
Environment information
If this symbol appears on electrical products or on its packaging, this means that they must be recycled properly. Please
ensure that you are well informed of the local rules and regulations regarding to the removal of equipment and accessories.
Troubleshooting
The top sections cannot be adjusted
The supporting gas springs might “stick” if the couch has not been used for a long time
• In such a case, push the corresponding lever with your hand, wait for a few seconds and pull the table section upwards with
the other hand.
The electric adjustments do not work properly
• Check the power cable for any damage.
• Check all the plugs and connections.
Persisting problems
If problems persist, please contact the dealer and provide the serial number and model of the table as they appear on the
identification plate (refer to the illustration).
QR code
Naggura
NRUN16018481215684515-1
N_RUN308-1 . 000000004
N’RUN

11
Instruction
Manual
Our products are subject to
continuous technical improvements.
Naggura reserves the rightto
change ormodify the product and
contents without prior notice.
N’RUN

www.naggura.com
Naggura
Pol. Ind. La Valldan
Camí de Garreta, 92
08600 Berga
Barcelona - Spain
T. +34 93 824 90 20
www.naggura.com
* Las imágenes tienen carácter orientativo y no son contractuales.
Other manuals for N'RUN Series
2
This manual suits for next models
5
Table of contents
Other Naggura Medical Equipment manuals