7
W415-0811 / A / 04.28.10
2.3 GENERAL INFORMATION
This appliance is approved for bathroom, bedroom and bed-sitting room
installations and is suitable for mobile home installation.
No external electricity (110 volts or 24 volts) is required for the gas system
operation. Expansion / contraction noises during heating up and cooling
down cycles are normal and are to be expected.
If utilizing one of Wolf Steel's trim or surround kits, follow the framing
instructions and the finishing instructions, for removal of the top extension.
NOTE: The protective wrap on plated parts is best removed when the assembly is at room temperature but this
can be improved if the assembly is warmed, using a hair dryer or similar heat source.
66.8%
BGD40
4.1
If the appliance is installed directly on carpeting, vinyl tile or other combustible material other than wood
flooring, the appliance shall be installed on a metal or wood panel extending the full width and depth.
If the optional fan or blower is installed, the junction box must be electrically connected and grounded in
accordance with local codes, use the current CSA C22.1 Canadian Electrical Code in Canada or the ANSI/
NFPA 70 National Electrical code in the United States.
2.4 RATING PLATE INFORMATION
TOP, FLOOR, SIDES & BACK
DESSUS, PLANCHER, COTES & ARRIERE
RECESSED DEPTH (CORNER INSTALLATION ONLY)
PROFONDEUR D'ENCASTRE (INSTALLATION DU COIN SEULEMENT)
VENT / EVENT 1"
MANTLE HEIGHT / HAUTEUR DU MANTEAU 5"*
NOT FOR USE WITH SOLID FUEL. FOR USE WITH COVERS AND
GLASS DOORS CERTIFIED WITH THIS UNIT ONLY.
WARNING:DO NOT ADD ANY MATERIAL TO THE APPLIANCE, WHICH WILL COME IN CONTACT
WITHTHE FLAMES, OTHER THANTHAT SUPPLIEDBY THEMANUFACTURER WITHTHE APPLIANCE.
MINIMUM CLEARANCE TO COMBUSTIBLE MATERIALS /
DEGAGEMENTS MINIMAUX DES MATERIAUX COMBUSTIBLES:
UN COMBUSTIBLE SOLIDE NE DOIT PAS ETRE UTILISE AVEC CET
APPAREIL. UTILISER AVEC LES COUVERTURES ET LES PORTES
VITREES HOMOLOGUEES SEULEMENT AVEC CETTE UNITE.
AVERTISSEMENT: N'AJOUTEZ PAS A CET APPAREIL AUCUN MATERIAU DEVANT ENTRER EN
CONTACT AVEC LES FLAMMES AUTRE QUE CELUI QUI EST FOURNI AVEC CET APPAREIL PAR LE
FABRICANT.
THEAPPLIANCE MUST BEVENTED USINGTHEAPPROPRIATE WOLF STEEL VENT KITS. SEEOWNERS
INSTALLATION MANUAL FOR VENTING SPECIFICS. PROPER REINSTALLATION AND RESEALING IS
NECESSARY AFTER SERVICING THE VENT-AIR INTAKE SYSTEM.
L'APPAREIL DOIT EVACUER SES GAZ EN UTILISANT L'ENSEMBLE D'EVACUATION PROPRE A WOLF
STEEL. REFERER AUMANUEL D'INSTALLATION DE PROPRIETAIRE POURL'EVACUATION PRECISE. IL
ESTIMPORTANT DE BIEN REINSTALLERET RESCELLER L'EVENT APRESAVOIR ASSURE LE MAINTIEN
DU SYSTEME DE PRISE D'AIR.
ELECTRICAL RATING / CLASSIFICATION: 115V, 0.82AMP, 60HZ
OPTIONAL FAN KIT / ENSEMBLE DE VENTILATEUR FACULTATIF: GZ-550KT
0
25¼"
* MAXIMUMHORIZONTALEXTENSION/L'EXTENSIONHORIZONTALE MAXIMALE: 3". SEEINSTRUC-
TION MANUAL FOR GREATER EXTENSIONS. REFERER AU MANUEL D'INSTRUCTION POUR DES
EXTENSIONS PLUS GRANDES.
MINIMUM AND MAXIMUM HORIZONTAL VENT LENGTHS ARE 10 INCHES AND 20 FEET RESPEC-
TIVELY. LES LONGUEURS HORIZONTALES MINIMALE ET MAXIMALE SONT 10 POUCES ET 20 PIEDS
RESPECTIVEMENT.
WOLF STEEL LTD, BARRIE, ON, CANADA SERIAL NUMBER/NO. DE SERIE:
GD22
MADE IN CANADA / FABRIQUE AU CANADA
BGD40 / BCDV400 W385-0249
CERTIFIEDUNDER / HOMOLOGUE SELON LES NORMES: CSA 2.33-2002, ANSI Z21.88-2002 VENTED GAS FIREPLACE HEATER / FOYER DE CHAUFFAGE AU GAZ AVEC EVACUATION
DIRECT VENT GAS FIREPLACE.APPROVED FOR BEDROOM, BATHROOM AND BED-SITTING ROOM INSTALLATION. SUITABLE FOR MOBILE HOME INSTALLATION IF INSTALLED IN ACCORDANCE WITH THE
CURRENT STANDARD CAN/CSAZ240MH SERIES GAS EQUIPPED MOBILE HOMES, IN CANADAOR IN THE UNITED STATES THEMANUFACTURED HOME CONTRUCTIONAND SAFETY STANDARD,TITLE 24
CFR, PART 3280. WHENTHIS US STANDARD IS NOTAPPLICABLE USETHE STANDARD FOR FIRE SAFETY CRITERIA FOR MANUFACTURED HOME INSTALLATIONS,SITESAND COMMUNITIES, ANSI/ NFPA501A.
FOYER A GAZ VENTILE DIRECT. HOMOLOGUE POUR INSTALLATION DANS UNE CHAMBRE A COUCHER,UNE SALLE DEBAIN ET UN STUDIO. APPROPRIE POUR INSTALLATION DANS UNE MAISON MOBILE
SI SON INSTALLATION CONFORME AUX EXIGENCES DE LA NORME CAN/CSA Z240MH SERIE DE MAISONS MOBILES EQUIPEES AU GAZ, EN VIGUEUR AU CANADAOU AUX ETATS-UNIS DE LA NORME DE
SECURITE ET DE CONSTRUCTION DE MAISONS MANUFACTUREES,TITRE 24 CFR, SECTION 3280. DANS LE CAS OU CETTE NORME D'ETATS-UNIS NE PEUT ETREAPPLIQUEE, SE REFERERA LA NORME
RELATIVEAU CRITERE DE MESURES DE SECURITE CONTRE L'INCENDIE POUR LES INSTALLATIONS DANS LES MAISONS MANUFACTURES, LES SITES ET LES COMMUNAUTES, ANSI/NFPA 501A.
MANIFOLD PRESSURE: 3.5" WATER COLUMN
PRESSION AU COLLECTEUR: 3.5" D'UNE COLONNE D'EAU
MINIMUM SUPPLY PRESSURE: 4.5" WATER COLUMN
PRESSION D'ALIMENTATION MINIMALE: 4.5" D'UNE COLONNE D'EAU
MAXIMUM SUPPLY PRESSURE: 7.0" WATER COLUMN
PRESSION D'ALIMENTATION MAXIMAL: 7.0" D'UNE COLONNE D'EAU
ALTITUDE/ELEVATION: 0-4500FT(0-1370m)
INPUT/ALIMENTATION: 30,000 BTU/h
REDUCED INPUT/ALIMENTATION REDUIT:
20,000 BTU/h
ORIFICE: #39
ALTITUDE / ELEVATION: 0-4500FT (0-1370m)
INPUT /ALIMENTATION: 30,000 BTU/h
REDUCED INPUT / ALIMENTATION REDUIT:
20,000 BTU/h
ORIFICE: #52
MANIFOLD PRESSURE: 10" WATER COLUMN
PRESSION AU COLLECTEUR: 10" D'UNE COLONNE D'EAU
MINIMUM SUPPLY PRESSURE: 11" WATER COLUMN
PRESSION D'ALIMENTATION MINIMALE: 11" D'UNE COLONNE D'EAU
MAXIMUM SUPPLY PRESSURE: 13" WATER COLUMN
PRESSION D'ALIMENTATION MAXIMAL: 13" D'UNE COLONNE D'EAU
CANADA AND
ET
CERTIFIEDFOR
CERTIFIEEPOUR USA
MODEL BGD40 - N
MODELBCDV400- N MODEL BGD40 - P
MODELBCDV400- P
REFERENCE #15510
For rating plate
location, see
“INSTALLATION
OVERVIEW”
section.
APPLIANCE
NG LP
Altitude (FT) 0-4,500 0-4500
Max. Input (BTU/HR) 30,000 30,000
Max. Output Steady State (BTU/HR) 20,400 20,400
Min. Inlet Gas Supply Pressure 4.5" Water Column 11" Water Column
Max. Inlet Gas Supply Pressure 7" Water Column 13" Water Column
Manifold Pressure (Under Flow Conditions) 3.5" Water Column 10" Water Column
FOR YOUR SATISFACTION, THIS APPLIANCE HAS BEEN TEST-FIRED TO ASSURE ITS OPERATION AND
QUALITY!