8
W415-0098 / E / 06.28.10
2.4 RATING PLATE INFORMATION
DIRECTVENT MODELS GDS50/CDVS500
APPROVEDFORBEDROOM,BATHROOM&BEDSITTINGROOM
INSTALLATION.SUITABLE FOR MOBILE HOMEINSTALLATION
IF INSTALLED IN ACCORDANCE WITH THE CURRENT
STANDARD CAN/CSA Z240MH SERIES GAS EQUIPPED
MOBILE HOMES, IN CANADAOR IN THE UNITED STATES THE
MANUFACTURED HOME CONTRUCTION AND SAFETY
STANDARD, TITLE 24 CFR, PART 3280. WHEN THIS US
STANDARD IS NOT APPLICABLE USE THE STANDARD FOR
FIRE SAFETY CRITERIA FOR MANUFACTURED HOME IN-
STALLATIONS, SITES AND COMMUNITIES, ANSI / NFPA 501A.
HOMOLOGUE POUR INSTALLATION DANS UNE CHAMBRE A
COUCHER, UNE SALLE DE BAIN ET UN STUDIO. APPROPRIE
POUR INSTALLATION DANS UNE MAISON MOBILE SI SON
INSTALLATION CONFORME AUX EXIGENCES DE LA NORME
CAN/CSA Z240MH SERIE DE MAISONS MOBILES EQUIPEES
AU GAZ, EN VIGUEUR AU CANADA OU AUX ETATS-UNIS DE
LA NORME DE SECURITE ET DE CONSTRUCTION DE
MAISONS MANUFACTUREES, TITRE 24 CFR, SECTION 3280.
DANS LE CAS OU CETTE NORME D'ETATS-UNIS NE PEUT
ETRE APPLIQUEE, SE REFERER A LA NORME RELATIVEAU
CRITERE DE MESURES DE SECURITE CONTRE L'INCENDIE
POUR LES INSTALLATIONS DANS LES MAISONS MANUFAC-
TURES,LES SITES ETLES COMMUNAUTES,ANSI/NFPA501A
.
STEADY STATE EFFICIENCY (NG): 75% FAN OFF / 78% FAN ON
STEADY STATE EFFICIENCY (LP): 76% FAN OFF / 79% FAN ON
EFFICACITE CONSTANTE (GN): 75% VENT.ARRETE
78% VENT. FONCTIONNE
EFFICACITE CONSTANTE (GP): 76% VENTILATEUR ARRETE
79% VENTILATEUR FONCTIONNE
STEADYSTATE EFFICIENCYAPPLIESTOCANADAONLY / L'EFFICACITE
CONSTANTES'APPLIQUENTSEULEMENTAUCANADA.
AFUE (NG/LP) (GN/GP): 65% / 67%
MINIMUMAND MAXIMUM HORIZONTAL VENTLENGTHSARE
25 INCHES AND 20 FEET RESPECTIVELY. LES LONGUEURS
HORIZONTALES MINIMALE ET MAXIMALE SONT 25 POUCES
ET 20 PIEDS RESPECTIVEMENT.
THE APPLIANCE MUST BE VENTED USING THE APPROPRI-
ATE NAPOLEON VENT KITS. SEE OWNERS INSTALLATION
MANUAL FOR VENTING SPECIFICS. PROPER REINSTALLA-
TION AND RESEALING IS NECESSARY AFTER SERVICING
THE VENT-AIR INTAKE SYSTEM.
L'APPAREIL DOIT EVACUER SES GAZ EN UTILISANT
L'ENSEMBLE D'EVACUATION PROPRE A NAPOLEON.
REFERER AU MANUEL D'INSTALLATION DE PROPRIETAIRE
POUR L'EVACUATION PRECISE. IL ESTIMPORTANT DE BIEN
REINSTALLER ET RESCELLER L'EVENT APRES AVOIR AS-
SURE LE MAINTIEN DU SYSTEME DE PRISE D'AIR.
CERTIFIED UNDER/HOMOLOGUE SELON LES NORMES:
CSA2.33-2009,ANSIZ21.88-2009 VENTEDGASFIREPLACE HEATER
APPLIANCEMUSTBEINSTALLEDUSINGBURNERKIT:GDS50BN-KT,
ORGDS50BP-KT.
WOLF STEEL LTD
BARRIE,ONTARIOCANADA
MADE IN CANADA / FABRIQUE AU CANADA
W385-0181 / D
SERIALNUMBER
NO.DESERIE
*ALTITUDEDOWNRATINGCONDITIONSAPPLYTOCANADAONLY
LESCONDITIONSDEBAISSED’EVALUATIONSELONL’ALTITUDE
S’APPLIQUENTAUCANADASEULEMENT
MANIFOLDPRESSURE:3.5INCHESW.C.(NG)/10INCHESW.C.(LP)
PRESSIONAU COLLECTEUR:3.5"D'UNECOLONNED'EAU(GN)
10" D'UNE COLONNE D'EAU (PG)
MIN SUPPLY PRESSURE: 4.5" W.C.(NG) / 11" W.C. (LP)
PRESSIOND'ALIMENTATIONMIN:4.5"D'UNECOLONNED'EAU(GN)
11" D'UNE COLONNE D'EAU (PG)
MAX. SUPPLY PRESSURE: 7" W.C. (NG) / 13" W.C. (LP)
PRESSIOND'ALIMENTATIONMAX:7"D'UNECOLONNED'EAU(GN)
13" D'UNE COLONNE D'EAU (PG)
FOR USE WITH GLASS DOORS CERTIFIED WITH THIS UNITONLY.
UTILISER AVEC LES PORTES VITREES HOMOLOGUEES
SEULEMENTAVECCETTEUNITE.
WARNING: DO NOT ADD ANY MATERIAL TO THE APPLIANCE,
WHICHWILLCOMEINCONTACTWITHTHEFLAMES,OTHERTHAN
THATSUPPLIEDBYTHE MANUFACTURERWITHTHEAPPLIANCE.
AVERTISSEMENT: N'AJOUTEZ PASACETAPPAREILAUCUN
MATERIAU DEVANT ENTRER EN CONTACT AVEC LES
FLAMMES AUTRE QUE CELUI QUI EST FOURNIAVEC CET
APPAREIL PAR LE FABRICANT.
MINIMUMCLEARANCETOCOMBUSTIBLEMATERIAL/
DEGAGEMENTSMINIMAUXDESMATERIAUXCOMBUSTIBLES:
A7" D17½"
B2" E6¼"
C1" F9½"
20"TO CEILING FROM STOVE TOP
20" ENTRE LE DESSUS DU FOYER ET LE PLAFOND
ELECTRICAL RATING / CLASS.: 115V 1.5AMP 60HZ
B-VENT MODELS GS50/CS500 APPROVEDFORBED-
ROOM, & BEDSITTING ROOM INSTALLATION. HOMOLOGUE
POUR INSTALLATION DANS UNE CHAMBRE A COUCHER,
& UN STUDIO.
STEADYSTATEEFFICIENCY(NG): 71%FANOFF/77%FAN ON
STEADYSTATEEFFICIENCY(LP):73% FANOFF /78% FANON
EFFICACITE CONSTANTE (GN): 71% VENT.ARRETE
77% VENT. FONCTIONNE
EFFICACITECONSTANTE (GP):73%VENTILATEURARRETE
78% VENTILATEUR FONCTIONNE
STEADYSTATEEFFICIENCYAPPLIESTOCANADAONLY / L'EFFICACITE
CONSTANTES'APPLIQUENTSEULEMENTAUCANADA.
AFUE (NG/LP) (GN/GP): 64% / 67%
THISAPPLIANCEMUSTBEINSTALLEDUSINGANADAPTERKIT
GS-150KT. CET APPAREIL DOIT ETRE INSTALLE EN UTILISANT
UNENSEMBLEADAPTATEURGS-150KT.
NOT FOR USE WITH SOLID FUEL
UN COMBUSTIBLE SOLIDE NE DOIT PAS
ETRE UTILISEAVEC CETAPPAREIL GDS/CDVS50
CERTIFIED UNDER/HOMOLOGUE SELON LES NORMES:
CSA2.33-2009, ANSIZ21.88-2009 VENTED GASFIREPLACE
HEATER APPLIANCE MUST BE INSTALLED USING BURNER
KIT:GDS50BN-KT,ORGDS50BP-KT.
2000-4500FT(610-1370m)
40,000 BTU/h
18,000 BTU/h
30,000 BTU/h
28,400 BTU/h
#36
#45
ALTITUDE/ELEVATION
INPUT /ALIMENTATION
REDUCED INPUT /ALIMENTATION REDUITE
OUTPUT(MODEL GDS50) RENDEMENT
OUTPUT(MODEL GS50)RENDEMENT
FRONT ORIFICE / INJECTEURAVANT
TURBO ORIFICE / INJECTEUR TURBO
0-2000FT(0-610m)
44,000 BTU/h
20,000 BTU/h
33,000 BTU/h
31,200 BTU/h
#34
#43
0-2000FT(0-610m)
40,000 BTU/h
21,000 BTU/h
30,400 BTU/h
30,000 BTU/h
#53
#57
2000-4500FT(610-1370m)
36,000 BTU/h
18,000 BTU/h
27,400 BTU/h
26,400 BTU/h
#53
#59
**
GDS50 -P
GS50-P
CDVS50 -P
CS50-P
CDVS500 -N
CS500-N
GDS50 -N
GS50-N REFERENCE # W/N 15493
For rating plate location, see "INSTALLATION OVERVIEW" section
INSTALLER: It is your responsibility to check off the appropriate box on the rating plate according to the
model, venting and gas type of the unit.
This illustration is for reference only. Refer to the rating plate on the appliance for accurate information.
B
I
F
BIL
I
RDAN
AN
24
M
ME
,
I
ANAD
F
RED
TITL
24
ND
D
I
N
PP
AFETY
,
M
L
P
IN
I
L
A
P
PPLIAN
A
PP
I
AN
E
P
EI
L
E
F
RNI
DE
FR
M
T
V
T
P
DE
D
F
YE
E
CLASS.