Do not use abrasive cleaners to clean plated parts. Buff lightly with
a clean dry cloth.
DO NOT SUBSTITUTE MATERIALS. Clean the glass after the first 10
hours of operation with a recommended gas fireplace glass cleaner.
Thereafter clean as required.
DO NOT CLEAN GLASS WHEN HOT! If the glass is not kept clean
permanent discolouration and / or blemishes may result.
THIS GAS FIREPLACE SHOULD BE INSTALLED AND SERVICED BY A QUALIFIED INSTALLER to conform with local
codes. Installation practices vary from region to region and it is important to know the specifics that apply to your area,
for example: in Massachusetts State:
• The fireplace damper must be removed or welded in the open position prior to installation of a fireplace insert or gas log.
• A carbon monoxide detector is required in all rooms containing gas fired appliances.
• The appliance off valve must be a “T” handle gas cock.
• The flexible connector must not be longer than 36 inches.
• The appliance is not approved for installation in a bedroom or bathroom unless the unit is a direct vent sealed combustion product.
• WARNING: This product must be installed by a licensed plumber or gas fitter when installed within the commonwealth of
Massachusetts.
In absence of local codes, install to the current National Fuel Gas Code, ANSI Z223.1, or the current CAN/CGA B149,
Installation Codes. Mobile home installation must conform with local codes or in the absence of local codes, install to the
current standard for gas equipped mobile housing CAN/CSA ZA240 MH Series in Canada or the Manufactured Home
Construction and Safety Standard, Title 24 CFR, Part 3280, or the Fire Safety Criteria for Manufactured Home Installations,
Sites, and Communities Standard ANSI/NFPA 501A in the United States.
The fireplace and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure
testing of that system at test pressures in excess of 1/2 psig (3.5 kPa). The fireplace must be isolated from the gas supply
piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at
test pressures equal to or less than 1/2 psig (3.5 kPa).
When the fireplace is installed directly on carpeting, vinyl tile or other combustible
material other than wood flooring, the fireplace shall be installed on a metal or
wood panel extending the full width and depth.
If the optional blower is installed, the receptacle / junction box must be electrically
connected and grounded in accordance with local codes. In the absence of local
codes, use the current CSA C22.1 CANADIAN ELECTRICAL CODE in Canada
or the ANSI/NFPA 70 NATIONAL ELECTRICAL CODE in the United States.
FOR YOUR SATISFACTION, THIS FIREPLACE HAS BEEN TEST-FIRED TO ASSURE ITS OPERATION AND QUALITY!
GENERAL INSTRUCTIONS
GENERAL INFORMATION
CARE OF GLASS AND PLATED PARTS
GD34-1 RATES AND EFFICIENCIES
ALTITUDE (FT) 0 - 4,500
MAX. INPUT (BTU/HR) 22,000
MAX. OUTPUT (BTU/HR) 18,040
EFFICIENCY (w/ the fan on) 82%
GD34-1 GLASS TYPE BGD34-1 GLASS TYPE
3/16" Ceramic Glass* 3/16" Tempered Glass*
*Available from your Napoleon®/ Wolf Steel Ltd. dealer.
This fireplace is approved for bathroom, bedroom and bed-sitting room installations and is suitable for mobile home
installation.
No external electricity (110 volts or 24 volts) is required for the gas system operation.
Expansion / contraction noises during heating up and cooling down cycles are normal and are to be expected.
Provide adequate circulation air. Provide adequate accessibility clearance for servicing and operating the fireplace.
Never obstruct the front opening of the fireplace.
Objects placed in front of the fireplace must be kept at a minimum of 48" from the front face of the unit.
Use only Napoleon® accessories designed for and listed with the model.
BGD34-1 RATES AND EFFICIENCIES
ALTITUDE (FT) 0 - 4,500
MAX. INPUT (BTU/HR) 15,000
MAX. OUTPUT (BTU/HR) 11,700
EFFICIENCY (w/ the fan on) 78%