THIS APPLIANCE USES A 4” EXHAUST / 7” AIR INTAKE VENT PIPE SYSTEM.
Refer to the section applicable to your installation.
For safe and proper operation of the appliance follow the venting instruction exactly. Deviation from the
minimum vertical vent length can create difficulty in burner start-up and/or carboning. Under extreme vent
configurations, allow several minutes (5-15) for the flame to stabilize after ignition. Provide a means for
visually checking the vent connection to the appliance after the appliance is installed. Use a firestop, vent pipe
shield or attic insulation shield when penetrating interior walls, floor or ceiling.
NOTE: If for any reason the vent air intake system is disassembled; reinstall per the instructions
provided for the initial installation.
!
WARNING
RISK OF FIRE, MAINTAIN SPECIFIED AIR SPACE CLEARANCES TO VENT PIPE AND APPLIANCE.
IF VENTING IS INCLUDED WITH SPACERS THE VENT SYSTEM MUST BE SUPPORTED EVERY 3 FEET
FOR BOTH VERTICAL AND HORIZONTAL RUNS. USE SUPPORTS OR EQUIVALENT
NON-COMBUSTIBLE STRAPPING TO MAINTAIN THE REQUIRED CLEARANCE FROM
COMBUSTIBLES. USE WOLF STEEL LTD. SUPPORT RING ASSEMBLY W010-0370 OR EQUIVALENT
NON-COMBUSTIBLE STRAPPING TO MAINTAIN THE MINIMUM CLEARANCE TO COMBUSTIBLES
FOR BOTH VERTICAL AND HORIZONTAL RUNS. SPACERS ARE ATTACHED TO THE INNER PIPE AT
PREDETERMINED INTERVALS TO MAINTAIN AN EVEN AIR GAP TO THE OUTER PIPE. THIS GAP IS
REQUIRED FOR SAFE OPERATION. A SPACER IS REQUIRED AT THE START, MIDDLE AND END OF
EACH ELBOW TO ENSURE THIS GAP IS MAINTAINED. THESE SPACERS MUST NOT BE REMOVED.
2.4 RATING PLATE INFORMATION
*
MANIFOLD PRESSURE: 3.5"WATER COLUMN
PRESSION AU COLLECTEUR:3.5" D'UNE COLONNE D'EAU
MINIMUM SUPPLY PRESSURE: 4.5"WATER COLUMN
PRESSION D'ALIMENTATION MINIMALE: 4.5" D'UNE COLONNE D'EAU
MAXIMUM SUPPLY PRESSURE: 7.0" WATER COLUMN
PRESSION D'ALIMENTATION MAXIMALE: 7.0" D'UNE COLONNE D'EAU
NOT FOR USE WITH SOLID FUEL. FOR USE WITH GLASS
DOORS CERTIFIED WITH THIS UNIT ONLY.
WARNING:THIS FIREPLACE USES AND REQUIRES A FAST ACTING THERMOCOUPLE. REPLACE
ONLY WITH A FAST ACTING THERMOCOUPLE SUPPLIED BY WOLF STEEL LTD.
DO NOTADD ANYMATERIAL TOTHE APPLIANCE,WHICHWILL COME INCONTACT WITHTHE FLAMES,
OTHER THAN THAT SUPPLIEDBY THE MANUFACTURER WITH THE APPLIANCE.
MINIMUM CLEARANCE TO COMBUSTIBLE MATERIALS /
DEGAGEMENTS MINIMAUX DES MATERIAUX COMBUSTIBLES:
TOP/ DESSUS 0 RECESSED DEPTH / PROFONDEUR D'ENCASTRE 13"
FLOOR / PLANCHER 0 MANTLE / MANTEAU
VENT TOP / EVENT SUPERIEUR 2”
SIDES / COTES 0 VENT BOTTOM / EVENT INFERIEUR 1”
VENT SIDES / COTES DE L’EVENT 1”
2"
BACK / ARRIERE 0
TOP, SIDES & BACK: PER STAND OFF SPACERSFOR FRAMING MATERIALS. FOR FINISHING
MATERIALS SEE OWNERS MANUAL / DESSUS, COTES& ARRIERE: SELONLESESPACEURS DE
DEGAGEMENT POUR LES MATERIAUX D'OSSATURE SELON LE MANUEL DE PROPRIETAIRE
POUR LES MATERIAUX DE FINITION.
MAXIMUMHORIZONTALEXTENSION/L'EXTENSIONHORIZONTALEMAXIMALE: 2".SEE
INSTRUCTION MANUAL FOR GREATER EXTENSIONS. REFERER AU MANUEL
D'INSTRUCTION POUR DES EXTENSIONS PLUS GRANDES.
DIRECT VENT VENTED GAS FIREPLACE HEATER . APPROVED FOR BEDROOM, BATHROOM AND BED-SITTING ROOM INSTALLATION. SUITABLE FOR MOBILE
HOME INSTALLATION IFINSTALLEDINACCORDANCE WITHTHE CURRENTSTANDARD CAN/CSA Z240MH SERIES GAS EQUIPPEDMOBILEHOMES, INCANADA
OR INTHE UNITED STATESTHE MANUFACTURED HOME CONTRUCTIONAND SAFETYSTANDARD, TITLE 24 CFR,PART 3280. WHEN THISUS STANDARDIS NOT
APPLICABLE USE THE STANDARD FOR FIRE SAFETY CRITERIA FOR MANUFACTURED HOME INSTALLATIONS, SITES AND COMMUNITIES, ANSI / NFPA 501A.
APPAREIL DE CHAUFFAGE AU GAZVENTILÉA L'EVACUATION DIRECTE. HOMOLOGUEPOUR INSTALLATIONDANSUNE CHAMBRE ACOUCHER,UNE SALLE DE
BAIN ET UN STUDIO. APPROPRIE POUR INSTALLATION DANS UNE MAISON MOBILE SI SON INSTALLATION CONFORME AUX EXIGENCES DE LA NORME
CAN/CSA Z240MH SERIE DE MAISONS MOBILES EQUIPEES AU GAZ, EN VIGUEUR AU CANADA OU AUX ETATS-UNIS DE LA NORME DE SECURITE ET DE
CONSTRUCTIONDE MAISONS MANUFACTUREES, TITRE24 CFR,SECTION 3280.DANS LECAS OUCETTE NORMED'ETATS-UNIS NE PEUT ETREAPPLIQUEE,
SE REFERERALANORME RELATIVE AUCRITERE DEMESURES DE SECURITECONTRE L'INCENDIEPOURLES INSTALLATIONSDANSLES MAISONSMANUFAC-
TURES, LES SITES ET LES COMMUNAUTES, ANSI/NFPA 501A.
*
MANIFOLD PRESSURE: 10" WATER COLUMN
PRESSION AU COLLECTEUR:10" D'UNE COLONNE D'EAU
MINIMUM SUPPLY PRESSURE: 11" WATER COLUMN
PRESSION D'ALIMENTATION MINIMALE: 11" D'UNE COLONNE D'EAU
MAXIMUM SUPPLY PRESSURE: 13" WATER COLUMN
PRESSION D'ALIMENTATION MAXIMALE: 13" D'UNE COLONNE D'EAU
UN COMBUSTIBLE SOLIDE NE DOIT PAS ETRE UTILISE AVEC CET
APPAREIL. UTILISER AVEC LES PORTES VITREES HOMOLOGUEES
SEULEMENT AVEC CETTE UNITE.
AVERTISSEMENT:CE FOYER UTILISE ET REQUIERT UN THERMOCOUPLE À ACTION RAPIDE. REMPLACEZ
UNIQUEMENT AVEC UN THERMOCOUPLE À ACTION RAPIDE DE WOLF STEEL LTÉE.
N'AJOUTEZ PAS A CET APPAREIL AUCUN MATERIAU DEVANT ENTRER EN CONTACT AVEC LES FLAMMES AUTRE
QUE CELUI QUI EST FOURNI AVEC CET APPAREILPAR LE FABRICANT.
THE APPLIANCE MUST BE VENTED USINGTHE APPROPRIATEWOLFSTEELVENTKITS. SEEOWNERS INSTALLATION
MANUAL FOR VENTING SPECIFICS. PROPER REINSTALLATION ANDRESEALING ISNECESSARY AFTERSER VICING
THE VENT-AIR INTAKE SYSTEM.
L'APPAREIL DOITEVACUERSES GAZEN UTILISANTL'ENSEMBLE D'EVACUATION PROPREA WOLF STEEL.REFERER
AU MANUEL D'INSTALLATION DE PROPRIETAIRE POUR L'EVACUATION PRECISE. IL EST IMPORTANT DE BIEN
REINSTALLER ETRESCELLER L'EVENT APRES AVOIR ASSURE LE MAINTIEN DU SYSTEME DE PRISE D'AIR.
THIS VENTED GAS FIREPLACE HEATER IS NOT FOR USE WITH AIR FILTERS.
CET APPAREIL DE CHAUFF AGE AU GAZ NE DOIT PAS ÊTRE UTILISÉ CONJOINTEMENT AVECDES FILTRES À AIR.
ELECTRICAL RATING / CLASSIFICATION: 115V 0.82AMP, 60HZ
OPTIONAL FAN KIT / ENSEMBLE DE VENTILATEUR FACULTATIF: GZ550-1KT
W385-0393 / D
SERIAL NUMBER/NO. DE SERIE: GD34-1
ALTITUDE / ELEVATION
INPUT/ ALIMENTATION
REDUCED INPUT/ ALIMENTATION REDUITE
NATURAL GAS MODEL
0-4500FT (0-610m)
22,000 BTU/h
13,500 BTU/h
GD34-1NT GD34-1NTE
CDV34-1NT CDV34-1NTE
PROPANE MODEL
0-4500FT (0-610m)
22,000 BTU/h
13,500 BTU/h
VENTED GAS FIREPLACE/
FOYER AU GAZ AVEC EVACUATION
$16,=E&6$E
GD34-1PT GD34-1PTE
CDV34-1PT CDV34-1PTE
WOLF STEEL LTD.
24 NAPOLEON ROAD, BARRIE, ON, L4M 4Y4 CANADA
XXXXXX
For rating plate location, see “INSTALLATION OVERVIEW” section.
This illustration is for reference only. Refer to the rating plate on the appliance for accurate information.
RMOCOUPLE. REPLACEOUPLE. REPLACE
WITH
THEFLAME
NDEUR D'ENCASTRED'ENCASTRE
ES DE L’EVENTES DE L’EVEN
FOR FRAMING MAFOR FRAMING
ARRIERE:SELON LES EARRIERE:SELON LES E
TURE SELON LE MANUELTURE SELON LE MANUEL
ENSION/ L'EXTENSION HORIZON
TER EXTENSIONS.TER EXTENSIONS
NSIONS PLUS GRANDS PLUS GRAND
ACTURED HOME INSTTURED HOME INST
LL
OMOLOGUEPOUR INSTUEPOUR INST
LL
AISON MOBILE SI SON INSTE SI SON INST
LL
SECTION 3280.DANS LE CAS OU CETTSECTION3280. DANSLE CAS OU CETT
DESECURITE CONTRE L'INCENDIEPOUDESECURITE CONTRE L'INCENDIEPO
ANIFOLD PRESSURE:
PRESSION AU COLLECTEUR:PRESSION AU COLLEC
MINIMUM SUPPLMINIMUM SUPPL
PRESSION D'ALIMENTPRESSION D'ALIMENT
PRESSION D'ALIMEPRESSION D'AL
AP
INP
3.0 VENTING