2.3 GENERAL INFORMATION
61.4%
GDI44
When the appliance is installed at elevations above 4,500ft, and in the absence of specific recommendations
from the local authority having jurisdiction, the certified high altitude input rating shall be reduced at the rate of
4% for each additional 1,000ft.
Expansion / contraction noises during heating up and cooling down cycles are normal and to be expected.
In order to achieve maximum turn down rate, the rear burner must be turned off. See Operating Instructions in
the owner's manual for more information.
This appliance is not approved for closet or recessed installations. It is approved for bathroom, bedroom and
bed-sitting room installations and is suitable for mobile homes. The natural gas model is suitable for installation
in a mobile home that is permanently positioned on its site and fuelled with natural gas.
This appliance must be recessed into a vented noncombustible wood-burning fireplace (prefabricated or
masonry) only.
GDI44
NG LP
Altitude (FT) 0-4,500 0-4,500
Max. Input (BTU/HR) 40,000 40,000
Max. Output (BTU/HR) 27,600 27,600
Efficiency (w/the fan on) 69% 69%
Min. Inlet Gas Supply
Pressure 4.5" Water Column 11" Water Column
Max. Inlet Gas Supply
Pressure 7" Water Column 13" Water Column
Manifold Pressure (Under
Flow Conditions) 3.5" Water Column 10" Water Column
FOR YOUR SATISFACTION, THIS APPLIANCE HAS BEEN TEST-FIRED TO ASSURE ITS
OPERATION AND QUALITY!
2.4 RATING PLATE INFORMATION
W385-0252 / F
SERIALNUMBER
NO.DESERIE
GDI / CDI-44
GDI-44N / CDI-44N MODEL GDI-44P / CDI-44P
0 - 4500FT ALTITUDE/ELEVATION 0 - 4500FT
40,000 BTU/h INPUT /ALIMENTATION 40,000 BTU/h
13,000 BTU/h REDUCED INPUT / ALIMENTATION REDUITE 10,000 BTU/h
THIS FIREPLACE USES AND REQUIRESA FAST ACTING THERMOCOUPLE. REPLACE
ONLY WITHA FAST ACTING THERMOCOUPLE SUPPLIED BY WOLF STEEL LTD.
APPROVED FOR BEDROOM, BATHROOM & BEDSITTING ROOM INSTALLATION. SUITABLE
FOR MOBILE HOME INSTALLATION IF INSTALLED IN ACCORDANCE WITH THE CURRENT
STANDARD CAN/CSAZ240MH SERIES GAS EQUIPPED MOBILE HOMES, IN CANADA OR IN
THE UNITED STATES THE MANUFACTURED HOME CONSTRUCTION AND SAFETY
STANDARD, TITLE 24 CFR, PART 3280. WHEN THIS US STANDARD IS NOTAPPLICABLE
USE THE STANDARD FOR FIRE SAFETYCRITERIA FOR MANUFACTURED HOME
INSTALLATIONS, SITES AND COMMUNITIES, ANSI / NFPA 501A.
HOMOLOGUE POUR INSTALLATION DANS UNE CHAMBRE A COUCHER, UNE SALLE DE
BAIN ET UN STUDIO. APPROPRIE POUR INSTALLATION DANS UNE MAISON MOBILE SI
SON INSTALLATION CONFORME AUX EXIGENCES DE LA NORME CAN/CSAZ240MH
SERIE DE MAISONS MOBILES EQUIPEES AU GAZ, EN VIGUEURAU CANADA OUAUX
ETATS-UNIS DE LA NORME DE SECURITE ET DE CONSTRUCTION DE MAISONS
MANUFACTUREES, TITRE 24 CFR, SECTION 3280. DANS LE CAS OU CETTE NORME
D'ETATS-UNIS NE PEUT ETRE APPLIQUEE, SE REFERER ALA NORME RELATIVE AU
CRITERE DE MESURES DE SECURITE CONTRE L'INCENDIE POUR LES INSTALLATIONS
DANS LES MAISONS MANUFACTURES, LES SITES ET LES COMMUNAUTES,ANSI/NFPA
501A.
MINIMUM AND MAXIMUM VERTICALVENT LENGTHS ARE 7 FEETAND 40 FEET
RESPECTIVELY. LES LONGUEURS VERTICALES MINIMALES ET MAXIMALES SONT 7
PIEDS ET 40 PIEDS RESPECTIVEMENT.
MANIFOLD PRESSURE: 3.5 INCHES W.C. (NG) / 10 INCHES W.C.(LP)
PRESSION AU COLLECTEUR : 3.5" D'UNE COLONNE D'EAU(GN) / 10" D'UNE COLONNE
D'EAU (P)
MIN SUPPLY PRESSURE: 4.5" W.C.(NG) / 11" W.C. (LP)
PRESSION D'ALIMENTATION MIN : 4.5" D'UNE COLONNE D'EAU (GN) / 11" D'UNE
COLONNE D'EAU (P)
MAX. SUPPLY PRESSURE: 7" W.C. (NG) / 13" W.C. (LP)
PRESSION D'ALIMENTATION MAX : 7" D'UNE COLONNE D'EAU (GN) / 13" D'UNE
COLONNE D'EAU (P)
FOR USE WITH GLASS DOORS CERTIFIED WITH THIS UNIT ONLY.
UTILISER AVEC LES PORTES VITREES HOMOLOGUEES SEULEMENT AVEC CETTE
UNITE.
WARNING: DO NOTADD ANY MATERIAL TO THE APPLIANCE, WHICH WILLCOME IN
CONTACT WITHTHE FLAMES, OTHER THAN THAT SUPPLIED BY THE MANUFACTURER
WITH THE APPLIANCE.
AVERTISSEMENT : N'AJOUTEZ PAS A CETAPPAREILAUCUN MATERIAU DEVANT
ENTRER EN CONTACTAVEC LES FLAMMES AUTRE QUE CELUI QUI EST FOURNIAVEC
CET APPAREIL PAR LE FABRICANT.
ELECTRICAL RATING / CLASS.: 115V 1.5AMP 60HZ
THE APPLIANCE MUST BE VENTED USING THEAPPROPRIATE WOLF STEEL VENT KITS.
SEE OWNERS INSTALLATION MANUAL FOR VENTING SPECIFICS. PROPER
REINSTALLATION AND RESEALING IS NECESSARY AFTER SERVICING THE VENTAIR
INTAKE SYSTEM.
L'APPAREILDOIT EVACUER SES GAZ EN UTILISANTL'ENSEMBLE D'EVACUATION
PROPRE AWOLF STEEL. REFERER AU MANUEL D'INSTALLATION DE PROPRIETAIRE
POUR L'EVACUATION PRECISE. IL EST IMPORTANTDE BIEN REINSTALLER ET
RESCELLER L'EVENT APRESAVOIRASSURE LE MAINTIEN DU SYSTEME DE PRISE D'AIR.
WARNING: FOR INSTALLATION INTO AVENTED NON-COMBUSTIBLE FIREPLACE
ONLY. THE MINIMUM FIREPLACE SIZE IS: HEIGHT 21”, DEPTH 16”, WIDTH 32”. THE
MINIMUM INSIDE FLUE SIZE IS 7”. THE MINIMUM DISTANCE, FROMTHE BOTTOM OF A
COMBUSTIBLE MANTLE PROJECTING AMAXIMUM 3” FROM THE WALLTO THE TOP OF
THE STANDARD TRIM IS 12”. SEE OWNERS MANUALFOR GREATER EXTENSIONS.
A HEARTH MUST PROTRUDEA MINIMUM OF 12” FROM THE UNIT.
ATTENTION : POUR INSTALLATION DANS UN FOYER VENTILE EN MACONNERIE.
LES DIMENSIONS MINIMUMS SONT: HAUTEUR 21”, PROFONDEUR 16”, LARGEUR 32”. LE
DIAMETRE INTERIEUR MINIMUM DE CONDUIT D’EVACUATION EST DE 7”.
LA DISTANCE MINIMALE, DU BAS DU MANTEAU COMBUSTIBLE FORMANT UNE
PROJECTION MAXIMALE DE 3” DU MUR AU DESSUS DE LAGARNITURE NORMALE EST
12”. REFERER AU MANUEL D’INSTALLATION POUR DES EXTENSIONS PLUS GRANDES.
UNE DALLE DE PROTECTION INCOMBUSTIBLE DOIT SE PROLONGER D’AU MOINS 12" DE
L’UNITÉ.
NOT FOR USE WITH SOLID FUEL / UN COMBUSTIBLE
SOLIDE NE DOIT PAS ETRE UTILSE AVEC CET APPAREIL
WOLF STEEL LTD.
24 NAPOLEON ROAD, BARRIE, ON, L4M 0G8 CANADA
9700539 (WSL) 4001657 (NGZ)
4001658 (NAC) 4001659 (WUSA)
CERTIFIED UNDER: CSA 2.22b-2009,ANSI
Z21.50b-2009 VENTEDGAS FIREPLACE. HOMOLOGUESELON LESNORMES: CSA
2.22b-2009, ANSI Z21.50b-2009 FOYER
GAZ AVEC EVACUATION.
UCTION DE MAISONSUCTION DE
S LE CAS OU CETTE NORMELE CAS OU CET
RER ALA NORME RELATIVE AULA NORME RELATIVE AU
NCENDIE POUR LES INSTALLATIONSENDIE POUR LES INSTALLATIONS
ES ET LES COMMUNAUTES, ANSI/NFPAES ET LES COMMUNAUTES, ANSI/NFPA
LENGTHS ARE 7 FEETAND 40 FEETLENGTHS ARE 7 FEETAND 40 FEET
TICALES MINIMALES ET MAXIMALES SONTICALES MINIMALES ET MAXIMALES SONT
S W.C. (NG) / 10 INCHES W.C.(LP)W.C. (NG) / 10 INCHES W.C
3.5" D'UNE COLONNE D'EAU(GN) / 10" D'UNE.5" D'UNE COLONNE D'EAU(
4.5" W.C.(NG) / 11" W.C. (LP).5" W.C.(NG) / 11" W.C. (LP)
4.5" D'UNE COLONNE D'EAU (GN4.5" D'UNE COLONNE D'EAU
7" W.
.
N
13" W.
.
LP
)7" W.C. (NG) / 13" W.C. (LP)
MENTATION MAX :MENTATION MAX :
7" D'UNE COLONNE D'EA7" D'UNE COLONNE D'E
WITH GLASS DOORS CERTIFIED WITH THISTH GLASS DOORS CERTIFIED WITH THIS
R AVEC LES PORTES VITREES HOMOLOGUEAVEC LES PORTES VITREES HOMOLOGU
DO NOT ADD ANY MATERIAL TO THNOT ADD ANY MATERIAL TO T
CONTACT WITH THE FLAMES, OTHER THANONTACT WITH THE FLAMES, OTHER THAN
WITH THE APPLIANCE.WITH THE APPLIANCE.
AVERTISSEMENT
N'AJOUTEZ PASA COUTEZ PAS
ENTRER EN CONTACTAVEC LES FLAENTRER EN CONTACTAVEC LES FL
CET APPAREIL PAR LE FABRICANTCET APPAREIL PAR LE FABRICAN
ELECTRICAL RATING / CLASS.:ELECTRICAL RATING / CLASS
THE APPLIANCE MUST BE VETHE APPLIANCE MUST BE V
SEE OWNERS INSTALLATISEE OWNERS INSTALLAT
REINSTALLATION AND RREINSTALLATION AND
INTAKE
Y
TEM.
L'APPAREIL DOIT EAPPAREIL D
INSTALLER: It is your responsibility to check off
the appropriate box on the rating plate according
to the model, venting and gas type of the
appliance.
For rating plate location, see “INSTALLATION
OVERVIEW” section.
This illustration is for reference only. Refer to the
rating plate on the appliance for accurate information.