W415-1362 / 11.11.14
7
EN
2.5 RATING PLATE INFORMATION
INSTALLER: It is your responsibility to check off the appropriate box on the rating plate according to
the model, venting and gas type of the appliance.
This illustration is for reference only. Refer to the rating plate on the appliance for accurate information.
NOTE: The rating plate must remain with the appliance at all times. It must not be removed.
W385-1982
NOT FOR USE WITH SOLID FUEL
GI3600
GI3600N
NATURAL GAS / GAZ MODEL
CONFORMS TO / CONFORMEAUX:ANSI Z21.50-2014, CERTIFIED TO / CERTIFIE CSA 2.22-2014 VENTED GAS FIREPLACE / FOYER À GAZ VENTILÉ.
GAS-FIRED VENTED GAS FIREPLACE. MUST BE RECESSED INTO A WOOBURNING NON-
COMBUSTIBLE FIREPLACE AND USE A LISTED VENT LINER. CERTIFIED FOR BEDROOM AND
BEDSITTING ROOM INSTALLATION.
FOYER À GAZ VENTILÉ. IL DOIT ETRE ENCASTRE DANS UN FOYER EN MACONNERIE ET
RACCORDE A UN CONDUIT HOMOLOGUE. CERTIFIE POUR INSTALLATION DANS UNE
CHAMBRE A COUCHER ET UN STUDIO.
MANIFOLD PRESSURE: 3.5 INCHES W.C. (NG)
PRESSION AU COLLECTEUR: 3.5" D'UNE
COLONNE D'EAU(GN)
MIN SUPPLY PRESSURE: 4.5" W.C.(NG)
PRESSION D'ALIMENTATION MIN: 4.5" D'UNE
COLONNE D'EAU (GN)
MAX. SUPPLY PRESSURE: 7" W.C. (NG)
PRESSION D'ALIMENTATION MAX: 7" D'UNE
COLONNE D'EAU (GN)
MANIFOLD PRESSURE: 10 INCHES W.C.(LP)
PRESSION AU COLLECTEUR: 10" D'UNE
COLONNE D'EAU (P)
MIN SUPPLY PRESSURE: 11" W.C. (LP)
PRESSION D'ALIMENTATION MIN: 11" D'UNE
COLONNE D'EAU (P)
MAX. SUPPLY PRESSURE: 13" W.C. (LP)
PRESSION D'ALIMENTATION MAX: 13" D'UNE
COLONNE D'EAU (P)
0-4500ft
24,000 BTU/h
16,000 BTU/h
15,900 BTU/h
57.5%
ALTITUDE / ELEVATION
INPUT / ALIMENTATION
REDUCED INPUT / ALIMENTATION REDUITE
OUTPUT / RENDEMENT
P4
NOT A SOURCE OF HEAT. FOR USE WITH GLASS
DOORS CERTIFIED WITH THIS UNIT ONLY. FOR USE
ONLY WITH BARRIER W565-0180. FOLLOW THE
INSTALLATION INSTRUCTIONS LOCATED IN
THE INSTALLATION MANUAL.
NON CONCU POUR CHAUFFER UTILISERAVEC LES
PORTES VITREES HOMOLOGUEES SEULEMENT
AVEC CETTE UNITE. POUR UNE UTILISER SEULMENT
AVEC BARRIÈRE W565-0180. SUIVEZ LES
INSTRUCTIONS D'INSTALLATION SE TROUVENT
DANS LE MANUEL D'INSTALLATION.
UN COMBUSTIBLE SOLIDE NE DOIT PAS
ETRE UTILSE AVEC CET APPAREIL
SERIAL NUMBER / NO. DESERIE
0-4500ft
22,000 BTU/h
17,000 BTU/h
15,900 BTU/h
62.3%
CBI360N GI3600P CBI360P
PROPANE MODEL
WOLF STEEL LTD.
24 NAPOLEON ROAD, BARRIE, ON, L4M 0G8 CANADA
9700539 (WSL) 4001657 (NGZ)
4001658 (NAC) 4001659 (WUSA)
WARNING: FOR INSTALLATION IN A VENTED NON-COMBUSTIBLE FIREPLACE ONLY. THE
FIREPLACE CHIMNEY MUST HAVE A PERMANENT VENT OPENING TO ATMOSPHERE OF NOT LESS
THAN 13 SQ. INCHES (84 SQ CM). THE MINIMUM FIREPLACE SIZE IS: HEIGHT 17½”, DEPTH 16½”,
WIDTH 25½”. THE MINIMUM INSIDE DIAMETER CHIMNEY FLUE SIZE IS 5”. THE MINIMUM DISTANCE,
FROM THE BOTTOM OF A COMBUSTIBLE MANTEL PROJECTING A MAXIMUM 6” FROM THE WALL TO
THE TOP OF THE UNIT IS 8”. THIS DECORATIVE APPLIANCE NEEDS FRESH AIR FOR SAFE OPERATION
AND MUST BE INSTALLED SO THERE ARE PROVISIONS FOR ADEQUATE COMBUSTION AND
VENTILATION AIR.
ELECTRICAL RATING: 115V, 0.82 AMPS, 60 HZ
OPTIONALFAN KIT: GZ550-KT
ATTENTION: POUR INSTALLATION DANS UN FOYER VENTILE EN MACONNERIE. LA CHEMINEE DU
FOYER DOIT AVOIR UNE OUVERTURE DE L’EVENT PERMANENTE VERS L’ATMOSPHERE D’AU MOINS 13
POUCES CA. (84 CM. CA.). LES DIMENSIONS MINIMUMS SONT: HAUTEUR 17½”, PROFONDEUR 16½”,
LARGEUR 25½”. LE DIAMETRE INTERIEUR MINIMUM DU CONDUIT D’EVACUATION EST DE 5”. LA DISTANCE
MINIMALE, DU BAS DU MANTEAU COMBUSTIBLE FORMANT UNE PROJECTION MAXIMALE DE 6” DU MUR
AU DESSUS DU FOYER EST 8”. PAR MESURE DE SECURITE, CET APPAREIL REQUIERT DE L’AIR FRAIS ET
DOIT ETRE INSTALLE DE FACON A ASSURER UN APPROVISIONNEMENT SUFFISANT D’AIR DE
COMBUSTION ET DE VENTILATION.
PRODUIT DÉCORATIF: NE PAS UTILISER COMME APPARIEL DE CHAUFFAGE.
DECORATIVE PRODUCT: NOT FOR USE AS A HEATING APPLIANCE
CLASS: 115V, 0.82 AMPS, 60 HZ
EMSEMBLE DEVENTILATIONFACULTATIF: GZ550-KT
ZE IS 5”. THE MINIMUM DISTANCE,
G A MAXIMUM 6” FROM THE WALL T
NEEDS FRESH AIR FOR SAFE OPERAT