8
W415-0098 / H / 03.19.12
2.4 RATING PLATE INFORMATION
W385-0181 / G
SERIALNUMBER
NO.DESERIE
NOT FOR USE WITH SOLID FUEL
UN COMBUSTIBLE SOLIDE NE DOIT PAS
ETRE UTILISEAVEC CETAPPAREIL GDS50
WOLF STEEL LTD.
24 NAPOLEON ROAD, BARRIE, ON, L4M 0G8 CANADA
0-2000FT 2000-4500FT ALTITUDE / ELEVATION 0-2000FT 2000-4500FT
(0-610m) (610-1370m) (0-610m) (610-1370m)
44,000 BTU/h 40,000 BTU/h *INPUT /ALIMENTATION* 40,000 BTU/h 36,000 BTU/h
20,000 BTU/h 18,000 BTU/h REDUCED INPUT /ALIMENTATION REDUITE 21,000 BTU/h 18,000 BTU/h
33,000 BTU/h 30,000 BTU/h OUTPUT(MODEL GDS50) RENDEMENT 30,400 BTU/h 27,400 BTU/h
31,200 BTU/h 28,400 BTU/h OUTPUT(MODEL GS50) RENDEMENT 30,000 BTU/h 26,400 BTU/h
CERTIFIED UNDER: CSA2.33-2009, ANSI Z21.88 -2009 VENTED GAS FIREPLACE HEATER
HOMOLOGUE SELON LES NORMES CSA 2.33-2009, ANSI Z21.88 -2009 APPAREIL DE CHAUFFAGE ALIMENTÉ AU GAZ ET VENTILÉ.
CDVS500-N GDS50-N GDS50-P CDVS500-P
CS500-N GS50-N GS50-P CS500-P
9700539 (WSL) 4001657 (NGZ)
4001658 (NAC) 4001659 (WUSA)
*ALTITUDE DOWNRATING CONDITIONS APPLY TO CANADA ONLY
LES CONDITIONS DE BAISSE D’EVALUATION SELON
L’ALTITUDE S’APPLIQUENT AU CANADA SEULEMENT
MANIFOLD PRESSURE: 3.5” W.C. (NG) / 10” W.C.(LP)
PRESSION AU COLLECTEUR:3.5" D'UNE COLONNE D'EAU(GN)
10" D'UNE COLONNE D'EAU (PG)
MIN SUPPLY PRESSURE: 4.5" W.C.(NG) / 11" W.C. (LP)
PRESSION D'ALIMENTATION MIN:4.5" D'UNE COLONNE D'EAU (GN)
11" D'UNE COLONNE D'EAU (PG)
MAX. SUPPLY PRESSURE: 7" W.C. (NG) / 13" W.C. (LP)
PRESSION D'ALIMENTATION MAX:7" D'UNE COLONNE D'EAU (GN)
13" D'UNE COLONNE D'EAU (PG)
FOR USE WITH GLASS DOORS CERTIFIED WITH THIS UNIT ONLY.
UTILISER AVEC LES PORTES VITREES HOMOLOGUEES
SEULEMENTAVEC CETTE UNITE.
WARNING: DO NOT ADD ANY MATERIAL TO THE APPLIANCE,
WHICH WILL COME IN CONTACT WITH THE FLAMES, OTHER THAN
THAT SUPPLIED BY THE MANUFACTURER WITH THE APPLIANCE.
AVERTISSEMENT: N'AJOUTEZ PAS A CET APPAREIL
AUCUN MATERIAU DEVANT ENTRER EN CONTACTAVEC
LES FLAMMES AUTRE QUE CELUI QUI EST FOURNI
AVEC CET APPAREIL PAR LE FABRICANT.
MINIMUM CLEARANCE TO COMBUSTIBLE MATERIAL /
DEGAGEMENTS MINIMAUX DES MATERIAUX
COMBUSTIBLES:
A7" D17½"
B2" E6¼"
C1" F9½"
20" TO CEILING FROM STOVE TOP
20" ENTRE LE DESSUS DU FOYER ET LE PLAFOND
ELECTRICAL RATING / CLASS.: 115V 1.5AMP 60HZ
B-VENT MODELS GS50/CS500 APPROVED
FOR BEDROOM, & BEDSITTING ROOM
INSTALLATION. HOMOLOGUE POUR INSTALLATION
DANS UNE CHAMBRE A COUCHER, & UN STUDIO.
STEADY STATE EFFICIENCY (NG): 71% FAN OFF / 77% FAN ON
STEADY STATE EFFICIENCY (LP): 73% FAN OFF / 78% FAN ON
EFFICACITE CONSTANTE (GN): 71% VENT. ARRETE
77% VENT. FONCTIONNE
EFFICACITE CONSTANTE (GP): 73% VENTILATEUR ARRETE
78% VENTILATEUR FONCTIONNE
STEADY STATE EFFICIENCYAPPLIES TO CANADA ONLY /
L'EFFICACITE CONSTANTE S'APPLIQUENT SEULEMENTAU CANADA.
AFUE (NG/LP) (GN/GP): 64% / 67%
THISAPPLIANCE MUST BE INSTALLED USING ANADAPTER
KIT GS-150KT. CETAPPAREIL DOIT ETRE INSTALLE EN
UTILISANT UN ENSEMBLEADAPTATEUR GS-150KT.
DIRECT VENT MODELS GDS50/CDVS500
APPROVED FOR BEDROOM, BATHROOM & BEDSITTING ROOM
INSTALLATION. SUITABLE FOR MOBILE HOME INSTALLATION
IF INSTALLED INACCORDANCE WITH THE CURRENT
STANDARD CAN/CSAZ240MH SERIES GAS EQUIPPED MOBILE
HOMES, IN CANADAOR IN THE UNITED STATES THE
MANUFACTURED HOME CONTRUCTION AND SAFETY
STANDARD, TITLE 24 CFR, PART 3280. WHEN THIS US
STANDARD IS NOTAPPLICABLE USE THE STANDARD FOR FIRE
SAFETY CRITERIAFOR MANUFACTURED HOME
INSTALLATIONS, SITESAND COMMUNITIES, ANSI / NFPA501A.
HOMOLOGUE POUR INSTALLATION DANS UNE CHAMBREA
COUCHER, UNE SALLE DE BAIN ET UN STUDIO.APPROPRIE POUR
INSTALLATION DANS UNE MAISON MOBILE SI SON INSTALLATION
CONFORMEAUX EXIGENCES DE LANORME CAN/CSA Z240MH
SERIE DE MAISONS MOBILES EQUIPEESAU GAZ, EN VIGUEURAU
CANADAOUAUX ETATS-UNIS DE LA NORME DE SECURITE ET DE
CONSTRUCTION DE MAISONS MANUFACTUREES, TITRE 24 CFR,
SECTION 3280. DANS LE CAS OU CETTE NORME D'ETATS-UNIS NE
PEUT ETREAPPLIQUEE, SE REFERER ALA NORME RELATIVE AU
CRITERE DE MESURES DE SECURITE CONTRE L'INCENDIE POUR
LES INSTALLATIONS DANS LES MAISONS MANUFACTURES, LES
SITES ET LES COMMUNAUTES,ANSI/NFPA501A.
STEADY STATE EFFICIENCY (NG): 75% FAN OFF / 78% FAN ON
STEADY STATE EFFICIENCY (LP): 76% FAN OFF / 79% FAN ON
EFFICACITE CONSTANTE (GN): 75% VENT.ARRETE
78% VENT. FONCTIONNE
EFFICACITE CONSTANTE (GP): 76% VENTILATEURARRETE
79% VENTILATEUR FONCTIONNE
STEADY STATE EFFICIENCYAPPLIES TO CANADA ONLY /
L'EFFICACITE CONSTANTE S'APPLIQUENT SEULEMENTAU CANADA.
AFUE (NG/LP) (GN/GP): 65% / 67%
MINIMUMAND MAXIMUM HORIZONTAL VENTLENGTHS ARE
25 INCHESAND 20 FEET RESPECTIVELY. LES LONGUEURS
HORIZONTALES MINIMALE ET MAXIMALE SONT 25 POUCES
ET 20 PIEDS RESPECTIVEMENT.
THEAPPLIANCE MUST BE VENTED USING THE
APPROPRIATE NAPOLEON VENT KITS. SEE OWNERS
INSTALLATION MANUAL FOR VENTING SPECIFICS. PROPER
REINSTALLATIONAND RESEALING IS NECESSARYAFTER
SERVICING THE VENT-AIR INTAKE SYSTEM.
L'APPAREIL DOITEVACUER SES GAZ EN UTILISANT
L'ENSEMBLE D'EVACUATION PROPREA NAPOLEON.
REFERERAU MANUEL D'INSTALLATION DE PROPRIETAIRE
POUR L'EVACUATION PRECISE. IL ESTIMPORTANT DE BIEN
REINSTALLER ET RESCELLER L'EVENTAPRES AVOIR
ASSURE LE MAINTIEN DU SYSTEME DE PRISE D'AIR.
For rating plate location, see "INSTALLATION OVERVIEW" section
INSTALLER: It is your responsibility to check off the appropriate box on the rating plate according to
the model, venting and gas type of the unit.
This illustration is for reference only. Refer to the rating plate on the appliance for accurate information.
E FLAMES, OTHER THANFLAMES, OTHER THAN
ER WITH THE APPLIANCE.R WITH THE APPLIANCE.
PAS A CET APPAREILAS A CET APPAREIL
ENTRER EN CONTACT AVECER EN CONTACT AVE
E CELUI QUI EST FOURNIUI EST FOURNI
R LE FABRICANT.R LE FABRICANT.
E TO COMBUSTIBLE MATERIAE TO COMBUSTIBLE MATERI
NIMAUX DES MATERIAUXMAUX DES MATERIAU
17½
6
F
9½
CEILING FROM STOVE TOPCEILING FROM STOVE TOP
T MODELS GDS50/CDMODELS GDS50/CD
R BEDROOM, BATHROOM & BEDS
N. SUITABLE FOR MOBILE HOME IE FOR MOBILE HOME
LED INACCORDANCE WITH THE CED INACCORDANCE WITH THE C
ARD CAN/CSAZ240MH SERIES GAARD CAN/CSAZ240MH SERIES GA
MES, IN CANADAOR IN THE UNITEDES, IN CANADAOR IN THE UNITE
MANUFACTURED HOME CONTRUCACTURED HOME CONTRU
STANDARD, TITLE 24 CFR, PARTSTANDARD, TITLE 24 CFR, PART
STANDARD IS NOTAPPLICABSTANDARD IS NOTAPPLICAB
SAFETY CRITERIAFOR MASAFETY CRITERIAFOR MA
INSTALLATIONS, SITESAINSTALLATIONS, SITES