7
W415-0695 / A / 06.07.10
2.4 RATING PLATE INFORMATION
INSTALLER: It is your responsibility to check off the appropriate box on the rating plate according to
the model, venting and gas type of the appliance.
For rating plate location, see “INSTALLATION OVERVIEW” section.
The illustration is for reference only. Refer to the rating plate on the appliance for accurate information.
CERTIFIED UNDER / HOMOLOGUE SELON LES NORMES: CSA 2.33-2009,ANSI Z21.88-2009 VENTED GAS FIREPLACE HEATER / APPAREIL DE CHAUFFAGEALIMENTÉAU GAZ ET VENTILÉ
VENTED GAS FIREPLACE HEATER. APPROVED FOR BEDROOM, BATHROOMAND BED-SITTING ROOM INSTALLATION. SUITABLE FOR MOBILE HOME INSTALLATION IF INSTALLED IN ACCORDANCE WITH THE CURRENT STANDARD
CAN/CSA Z240MH SERIES GAS EQUIPPED MOBILE HOMES, IN CANADAOR IN THE UNITED STATES THE MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARD, TITLE 24 CFR, PART 3280. WHEN THIS US STANDARD IS
NOT APPLICABLE USE THE STANDARD FOR FIRE SAFETY CRITERIA FOR MANUFACTURED HOME INSTALLATIONS, SITES AND COMMUNITIES, ANSI / NFPA 501A.
FOYER DE CHAUFFAGEAU GAZAVEC ÉVACUATION. HOMOLOGUÉ POUR INSTALLATION DANS UNE CHAMBRE À COUCHER, UNE SALLE DE BAIN ET UN STUDIO. APPROPRIÉ POUR INSTALLATION DANS UNE MAISON MOBILE SI
SON INSTALLATION CONFORME AUX EXIGENCES DE LANORME CAN/CSA Z240MH SÉRIE DE MAISONS MOBILES ÉQUIPÉES AU GAZ, EN VIGUEURAU CANADA OUAUX ÉTATS-UNIS DE LA NORME DE SECURITÉ ET DE
CONSTRUCTION DE MAISONS MANUFACTURÉES, TITRE 24 CFR, SECTION 3280. DANS LE CAS OU CETTE NORME D'ÉTATS-UNIS NE PEUT ÊTRE APPLIQUÉE, SE RÉFÉRERA LA NORME RELATIVE AU CRITÈRE DE MESURES DE
SÉCURITÉ CONTRE L'INCENDIE POUR LES INSTALLATIONS DANS LES MAISONS MANUFACTURÉS, LES SITES ET LES COMMUNAUTÉS, ANSI/NFPA 501A.
NOT FOR USE WITH SOLID FUEL.
FOR USE WITH GLASS DOORS
CERTIFIED WITH THIS UNIT ONLY.
WARNING: DO NOT ADD ANY MATERIAL TO
THE APPLIANCE, WHICH WILL COME IN
CONTACT WITH THE FLAMES, OTHER THAN
THAT SUPPLIED BY THE MANUFACTURER
WITH THE APPLIANCE.
MINIMUM CLEARANCE TO COMBUSTIBLE
MATERIALS:
TOP 0 RECESSED DEPTH 29"
FLOOR 0 VENT 2"
SIDES 0 MANTLE 8" *
BACK 0
TOP, SIDES & BACK: PER STAND OFF SPACERS FOR
FRAMING MATERIALS. FOR FINISHING MATERIALS
SEE OWNERS MANUAL
* MAXIMUM HORIZONTAL EXTENSION / L'EXTENSION
HORIZONTALE MAXIMALE: 2". SEE INSTRUCTION
MANUAL FOR GREATER EXTENSIONS.
SEE OWNER'S INSTRUCTION MANUAL FOR MINIMUM
AND MAXIMUM VENT LENGTHS.
UN COMBUSTIBLE SOLIDE NE DOIT
PAS ÊTRÉ UTILISÉ AVEC CET
APPAREIL. UTILISER AVEC LES
PORTES VITRÉES HOMOLOGUÉES
SEULEMENT AVEC CETTE UNITÉ.
AVERTISSEMENT: N'AJOUTEZ PAS ACET
APPAREIL AUCUN MATÉRIAU DEVANT ENTRER
EN CONTACT AVEC LES FLAMMESAUTRE QUE
CELUI QUI EST FOURNI AVEC CET APPAREIL
PAR LE FABRICANT.
DÉGAGEMENTS MINIMAUX DES MATÉRIAUX
COMBUSTIBLES:
DESSUS 0 PROFONDEUR D'ENCASTRÉ 29"
PLANCHER 0 ÉVENT 2"
CÔTES 0 MANTEAU 8" *
ARRIÉRE 0
DESSUS,COTÉS&ARRIÈRE: SELON LES ESPACEURS
DEDÉGAGEMENTPOURLES MATÉRIAUXD'OSSATURE
SELONLEMANUELDE PROPRIÉTAIREPOUR LES
MATÉRIAUX DE FINITION.
*L'EXTENSIONHORIZONTALE MAXIMALE: 2". RÉFÉRER
AUMANUELD'INSTRUCTION POUR DES EXTENSIONS
PLUSGRANDES.RÉFÉRERAU MANUEL D'INSTALLATION
DEPROPRIÉTAIRE.
MADE IN CANADA / FABRIQUÉ AU CANADA
WOLF STEEL LTD. BARRIE, ONTARIO, CANADA
ALTITUDE / ÉLÉVATION
INPUT / ALIMENTATION
REDUCED INPUT / ALIMENTATION RÉDUITE
ORIFICE / INJECTEUR
MANIFOLD PRESSURE /
PRESSION AU COLLECTEUR
MINIMUM SUPPLY PRESSURE /
PRESSION D'ALIMENTATION MINIMALE
MAXIMUM SUPPLY PRESSURE /
PRESSION D'ALIMENTATION MAXIMALE
0-4500FT (0-1370M)
43,000 BTU/H
29,000 BTU/H
#30
3.5" WATER COLUMN/D'UNE COLONNE D'EAU
4.5" WATER COLUMN/D'UNE COLONNE D'EAU
7.0" WATER COLUMN/D'UNE COLONNE D'EAU
0-4500FT (0-1370M)
43,000 BTU/H
26,000BTU/H
#49
10" WATER COLUMN/D'UNE COLONNE D'EAU
11" WATER COLUMN/D'UNE COLONNE D'EAU
13" WATER COLUMN/ D'UNE COLONNE D'EAU
THE APPLIANCE MUST BE VENTED USING THEAPPROPRIATE
NAPOLEON VENT KITS. SEE OWNERS INSTALLATION MANUAL
FOR VENTING SPECIFICS. PROPER REINSTALLATION AND
RESEALING IS NECESSARYAFTER SERVICING THE VENT-AIR
INTAKE SYSTEM.
L'APPAREIL DOIT ÉVACUER SES GAZ EN UTILISANT L'ENSEMBLE
D'ÉVACUATION PROPRE ANAPOLEON. RÉFÉRER AU MANUEL
D'INSTALLATION DE PROPRIÉTAIRE POUR L'ÉVACUATION
PRÉCISE. IL EST IMPORTANT DE BIEN RÉINSTALLER ET
RESCELLER L'ÉVENT APRÈSAVOIRASSURÉ LE MAINTIEN DU
SYSTÉME DE PRISE D'AIR.
CLASSIFICATION: 115V 0.82AMP, 60HZ W385-0294
MODEL
GD80NT MODEL
GD80PT
SERIAL NUMBER/NO. DE SÉRIE: GD80
ELECTRICAL RATING: 115V 0.82AMP, 60HZ
REFERENCE # 15529
ÉTATS-UNIS NE PEUT ÊTRE APPL
LES COMMUNAUTÉS, ANSI/NFPA
NTED USING THE APPROPRIAT