Navkom REX indoor2 User manual

USER MANUAL

2EN
TECHNICAL DATA
• Voltage 8 – 30V direct or alternating
• Use: maximum 150mA
• Number of codes: 100, of which 1 is an administrator code
• Length of code: optional, from 4 to 16 characters
• 2 separate relay exits
• 256-bit encrypted connection to the relay unit
• Capacitive illuminated keys
• Installation into a door wing
INDEX
1. DEVICE COMPONENTS ......................................................... 3
2. DESCRIPTION AND CORRECT USE OF KEYPAD ............ 4
3. ENTERING THE ADMINISTRATOR CODE .......................... 4
4. ENTERING THE USER CODE ................................................. 4
5. UNLOCKING THE DOORS ...................................................... 4
6. DELETING THE USER CODE .................................................. 4
7. CHANGING THE ADMINISTRATOR CODE ...................... 5
8. DELETING THE ENTIRE BASE ............................................... 5
9. RESTORING FACTORY SETTINGS (RESET) ...................... 5
10. DISABLING THE ILLUMINATION OF THE KEYPAD ........ 5
11. MAINTENANCE AND CLEANING OF THE DEVICE ........ 5
12. TABLE OF SIGNALS ................................................................. 6
13. ERROR DESCRIPTION AND ELIMINATION ...................... 7
14. MANUFACTURER’S WARRANTY ........................................ 7
15. QUICKGUIDE ............................................................................ 8
2. DESCRIPTION AND CORRECT USE OF KEYPAD
The keypad has 10 digits and two function keys: (the plus),
which is used for adding, and (the checkmark), which is used
for code deleting and conrming or for unlocking. The keypad is
illuminated with blue backlight. The function keys are illuminat-
ed with green backlight when a correct code has been inserted
or when a suitable function is being activated. Red backlight is
activated when the code is incorrect or when a suitable func-
tion is activated. Under strong light the illumination of the key-
pad is poorly visible and the keys will appear white. Should the
programming of the keypad be made under strong light, it is
recommended that you shade the keypad in order to better see
the illumination and the light signals. When any of the keys is
being pressed, you will hear a short beep, which signals that the
key has been activated.
The keys are capacitive, and each has a sensor underneath,
which detects a nger that has been pressed over. In order to
activate a key, you have to cover the entire digit with your n-
ger, by touching it lightly and quickly. If the nger approaches
the key slowly, it might not activate the key.
100 dierent codes can be stored in the keypad. Each code
can be of arbitrary length: at least 4 digits and not more than
16 digits. The rst code that is set is the administrator’s code.
1. DEVICE COMPONENTS
Factory
reset
Relay unit with
the reset button:
Keypad:

3
EN
Only with this code it is possible to change the functions of the
keypad and to add and delete other codes. There is only one
administrator’s code, stored in the keypad.
The keypad should be used only by the means of the nger. Do
not use hard or sharp objects for typing, as they can damage the
surface of the keypad.
3. ENTERING THE ADMINISTRATOR CODE
• Press the key for 3s.
• The blue LED will start blinking quickly. Choose which relay this
code will activate. If you press number 1, this code will activate
relay 1. If you press number 2, this code will activate relay 2.
If you press numbers 1 and 2 together, this code will activate
both relays at the same time. The chosen number(s) must be
pressed for 2s.
• The green LED lights up and and you will hear a 1 second long
beep.
• The blue LED starts blinking slowly.
• Now enter the administrator code. The code can consist of a
minimum of 4 and a maximum of 16 digits.
• Press for 1s for code conrmation.
• The green LED lights up and ayou will hear a 1 second long
beep.
• The administrator code has been saved.
ATTENTION: If you forget the administrator code, you
will no longer be able to control the device and will
have to reset it. How to reset the device is described in
the chapter »Restore Factory Settings.«
4. ENTERING THE USER CODE
• Press the key for 3s.
• When the blue LED starts blinking slowly, enter the administra-
tor code and press .
• The green LED lights up and you will hear a 1 second long
beep.
• The blue LED starts blinking quickly (This might not be visible
under strong light).
• Choose which relay this code will activate. If you press num-
ber 1, this code will activate relay 1. If you press number 2, this
code will activate relay 2. If you press numbers 1 and 2 together,
this code will activate both relays at the same time. The chosen
number(s) must be pressed for 2s.
• The green LED lights up and you will hear a 1 second long
beep.
• The blue and green LED start blinking alternately. Enter the
user code. The code can consist of a minimum of 4 and a max-
imum of 16 digits.
• Press for 1s for code conrmation.
• The green LED lights up and you will hear a 1 second long
beep.The user code has been saved.
The user code can only be used for unlocking the door. It cannot
be used for adding or deleting other codes. The user code can
be deleted at any time, using the administrator code. The key-
pad can store 99 user codes.
If you forget the user code, you can enter a new one, using the
administrator code, or delete the entire database start from the
beginning.
5. UNLOCKING THE DOORS
When at least one code has been entered, it can be used to
unlock the door:
• Type in the code.
• Press .
• The green LED will light up and you will hear a 1 second long
beep. The door will unlock.
Should you enter the wrong code, a red LED lights up and you will
hear 3 short beeps. The door will not unlock. If you enter a wrong
code for three times in a row, the keypad will lock itself for 10s.
During that time a code cannot be entered. If you enter a wrong
code for three more times in a row, the keypad will lock itself for
2 minutes.
6. DELETING THE USER CODE
• Press for 5s.
• When the blue LED will start blinking, enter the administrator
code and press .
• The green LED will light up and you will hear a 1 second long
beep.
• The green and red LED will start blinking alternately.
• Enter the user code you wish to delete and press for 1s.
• The green and red LED will light up and you will hear three 1
second long beeps The code has been deleted.
You can delete any user code. The administrator code cannot be
deleted however. It can only be changed or you can choose to
delete the entire database.
7. CHANGING THE ADMINISTRATOR CODE
• Press for 5s.
• When the blue LED will start blinking, enter the administrator
code and press .
• The green and red LED will start blinking alternately.
• Enter the old administrator code and press for 1s.

4EN
• The green LED will light up and you will hear a 1 second long
beep.
• The blue LED will start blinking. Enter a new administrator code
and press for 1s. The code can consist of a minimum of 4
• and a maximum of 16 digits.
• The green LED will light up and you will hear a 1 second long
beep
• The administrator code has been changed.
8. DELETING THE ENTIRE BASE
If the case of changing the owners or for any other reason, you
can delete the entire database and thus restore the device to
its original state.
• Press and together for 10s.
• Blue and red LED will start blinking alternately.
• Enter the administrator code and press .
• Blue and red LED will light up and a you will hear 5 beeps.
• The entire code base has been deleted.
ATTENTION: after this operation it is recommended
that you enter a new administrator code right away,
thus protecting the device from abuse!
9. RESTORING FACTORY SETTINGS (RESET)
If you have lost or forgotten the administrator code and the
device can no longer be controlled, the device can be reset or
restored to its factory settings. There is a small button on the
relay unit, which resets the device. Relay unit is located inside
the door next to the motor mechanism. The locking mechanism
must be unscrewed and taken out of the door prole in order
to access the relay unit. The device must be plugged in. Press
the button on the relay unit for 30s. After 30s the device will be
reset and put back to its original state.
10. DISABLING THE ILLUMINATION OF THE KEYPAD
The illumination of the keypad can be disabled so that it turns
o 15s after each function has ended.
• Press for 20s. After 3s the keypad starts blinking. Ignore that
and continue to hold , until 20s have passed.
• The green LED will start blinking.
• To disable the illumination, press for 3s or to enable the illu-
mination, press for 3s.
• If disabling the illumination has been selected, the green LED
will light up and you will hear 3 beeps. If enabling the illumi-
nation has been selected, the green LED lights up and you will
hear only one beep.
When the illumination is disabled, the blue illumination of the
keypad turns o 15s after any operation has ended. The illumi-
nation will turned back on by pressing any of the keys.
11. MAINTENANCE AND CLEANING OF THE DEVICE
The device does not require maintenance. Should the keypad
need cleaning, use a dry or slightly damp soft cloth. Do not use
aggressive detergents, solvents, lye or acids for cleaning. Use of
aggressive cleaning agents may damage the surface of the key-
pad and in this case complaints will be invalid.

5
EN
12. TABLE OF SIGNALS
LED BEEP FREQUENCY EXPLANATION
Blue No On constantly The device is ready and waiting for a code to be entered or a function to be
activated.
Blue No O
• The device has been turned o or is not plugged in.
• The device is ready, but the illumination has been turned o. Press any key to turn
it on.
Blue No Blinking
quickly
The device is waiting for a relay to be selected. Press No. 1 for relay 1, No. 2
for relay 2 or No. 1 and 2 together for both relays.
Blue No Blinking slowly The device is waiting for the administrator code to be entered.
Green Yes 1 x 1 s
• The code is correct.
• The code has been entered.
• A relay has been selected.
• Constant illumination has been selected.
Green Yes 3 x 1 s Disabling of the illumination function has been activated.
Green No Blinking
constantly The device is waiting for the illumination mode to be selected.
Green and red No Alternately
• Function of deleting the user code: Enter the user code which you would like to
delete.
• Function of changing the administrator code: Enter the old administrator code.
Green and red Yes 3 x 1 s The user code has been deleted.
Green and blue No Alternately Function of adding a user code: Enter a new user code.
Red Yes 3 x 0,2 s The code is incorrect.
Red No On constantly
A wrong code has been entered three times in a row and the device is
locked, at rst for 10 s. If a wrong code is entered three more times in a
row, the device will lock itself for 2 minutes.
Red No Blinking
constantly Device error.
Red and blue No Alternately Function of deleting the entire base: Enter the administrator code.
Red and blue Yes 5 x 1 s Function of deleting the entire base: The database has been deleted.

6EN
13. ERROR DESCRIPTION AND ELIMINATION
DESCRIPTION CAUSE
The keypad does not react
to the touch of a nger.
You did not use enough of the nger's surface to press the key. The nger must cover
the entire digit.
You drew the nger to the key too slowly. The key must be pressed quickly.
If the device still does not react after several attempts, it is malfunctioning and you
should call a repairman.
The door does not open
after entering the code.
You forgot to press after entering the code.
The code is incorrect.
The code has been deleted.
If the code is correct and after entering it a green LED lights up and a beep goes on for
1s, the electric lock is malfunctioning. Call a repairman.
I cannot see
the illumination of the
keypad.
Illumination of the keypad is poorly visible under the strong light.
The device's illumination has been disabled. Press any key to turn on the illumination.
The device has been turned o or is not plugged in.
The device is malfunctioning. Call a repairman.
The red LED is on constantly.
I cannot enter a code.
The wrong code has been entered 3 times in a row and the keypad is temporarily
locked.
The red LED is blinking
constantly. The device is malfunctioning. Call a repairman.
14. MANUFACTURER’S WARRANTY
Warranty conditions:
The warranty period is 24 months from the day of hand on of
the product to the nal customer. With this statement, the man-
ufacturer of the product, NAVKOM d.o.o., guarantees that in the
warranty period the REX-touchpad (the product) will operate
faultlessly and that the materials it is made of are faultless and
undamaged. If the customer nds a fault in the functioning of
the product, they can enforce the rights under the warranty on
the seller or the manufacturer, who shall issue a claim receipt.
The manufacturer undertakes that in the event of a justied
complaint they shall eliminate the malfunction no later than 45
days after the day of complaint. If the malfunction is impossi-
ble to repair, the customer will receive a new product from the
seller or the manufacturer no later than 45 days after the day
of complaint.
Notes concerning the warranty enforcement:
The customer assumes all risks and expenses incurred during
the transport of the product to the licensed seller or the licensed
service. The warranty is only valid if the warranty certicate is
completely lled in by Navkom d.o.o. or a licensed seller of the
product or if the circumstances of the purchase are satisfactori-
ly evidenced from other documents. Therefore, please ensure
that your name, the name of the seller, the serial number of the
product, the year, month and day of the purchase are written in
full in the original pro forma invoice or invoice; or see to it that
your purchase receipt showing the name of the seller, the date
of the purchase and type of product is attached to the original
warranty certicate. Navkom d.o.o. reserves the right to refuse
to provide repairs free of charge where the submitted warranty
certicate is not completely lled in and the above mentioned
document (invoice, bill) is not enclosed, or when the data on
the warranty certicate are not completed or are illegible. Keep
the warranty certicate in a safe place because we cannot issue
a duplicate.
Warranty extension:
In the case that the customer enforced the warranty and the li-
censed service found the complaint to be justied, the warranty

7
EN
period is extended for the time the product was at service. If the
respective product has undergone a major service intervention,
or if the product was replaced, a new warranty is issued to the
customer for a 24 month period.
The warranty cannot be enforced in the case of:
1. Any defect caused by improper handling of the product (e.g.
the use of the product with the intentions and in a manner not
specied in the instructions for use, handling and maintenance
etc.).
2. Any defect caused during repair, adaptation, cleaning or any
other intervention in the product by any other party except the
services licensed by Navkom d.o.o.
3. Any defect caused because of transport, fall, hit etc. after the
purchase of the product.
4. Any defect caused by burning/re, earthquake, ood, light-
ning, other natural disasters, polluted environment and im-
proper voltage of the electrical supply.
5. Any defect caused by negligent handling or inappropriate
storage of the product (e.g. keeping it at high temperatures or
high humidity, in the vicinity of insecticides, e.g. naphthalene,
or medicines, poisons or chemicals which can cause damage),
inappropriate maintenance etc.
6. When the product which was sent to repair is not accompa-
nied by the warranty certicate.
7. Any changes of the warranty certicate concerning the year,
month and day of purchase, name of the customer or seller and
serial number.
8. When the warranty certicate is not accompanied by the re-
ceipt for the item(s) purchased (invoice).
Limits of liability:
Navkom d.o.o. does not either represent or guarantee, explicitly
or implicitly, anything on behalf of the suppliers or in connec-
tion with the contents of written materials. It is in no way liable
to warrant the purchased material or its suitability for certain
purpose or any consequent injury, accidental damage or im-
mediate damage (including but not limited to the damage or
loss of business prots, the termination of business operations
and the loss of business information), derived from the use or
incapability of use of these printed materials or device. Some
countries do not allow limitations of liability concerning con-
sequential or accidental damage; therefore, it is possible that
the above mentioned provision does not apply. In the case that
the customer sends the reclaimed product via mail, it is advised
to secure the consignment. The seller and the manufacturer are
not liable for damage caused during transportation.
Serial number:
Purchase date:
Installation date:
Name of the customer:
Adress of the customer:
Stamp and signature of the seller:
REX-touchpad was manufactured by:
Navkom d.o.o., Prijateljeva 24, 1000 Ljubljana, Slovenija
[email protected], www.navkom.si
Product type:
Keypad based access control device

UNLOCKING THE DOOR
ADMINISTRATOR CODE
(rst code entered)
PRESS 3 s
BLUE IS FLASHING RAPIDLY.
CHOOSE THE RELAY:
Relay 1: number 1
Relay 2: number 2
Both relays:
numbers 1 and 2
GREEN + BEEP 1 s.
BLUE IS FLASHING
SLOWLY.
ENTER ADMIN. CODE 4 - 16
NUMBERS.
PRESS 1 s.
GREEN + BEEP 1 s
THE CODE SAVED.
LIGHTING MODE TURN OFF
AFTER 15 s
PRESS 20 s.
BLUE IS FLASHING AFTER
3 s (ignore and remain
pressing the button),
GREEN IS FLASHING.
SELECT LIGHTING MODE
TURN OFF AFTER 15 s:
PRESS 1 s.
GREEN + BEEP 3 X 1 s.
LIGHTING MODE TURNS
OFF 15 s AFTER THE END
OF EACH FUNCTION.
SELECT CONSTANT
LIGHTING:
PRESS 1 s.
GREEN + BEEP 1 s.
CONSTANT LIGHTING
TURNS ON.
USER CODE
PRESS 3 s.
BLUE IS FLASHING SLOWLY.
ENTER ADMIN. CODE.
PRESS .
GREEN + BEEP 1 s. BLUE IS
FLASHING RAPIDLY.
CHOOSE THE RELAY:
Relay 1: number 1
Relay 2: number 2
Both relays:
numbers 1 and 2
GREEN + BEEP 1 s.
BLUE IS FLASHING
SLOWLY.
ENTER USER CODE 4 - 16
NUMBERS.
PRESS 1 s.
GREEN + BEEP 1 s
CODE IS SAVED.
CHANGING
ADMINISTRATOR CODE
ENTER YOUR PASSWORD
AND PRESS .
GREEN + BEEP 1 s
THE DOOR UNLOCKS.
DELETE USER CODE
PRESS 5 s.
BLUE IS FLASHING.
ENTER ADMIN. CODE.
PRESS .
GREEN + BEEP 1 s.
GREEN AND RED ARE
FLASHING ALTERNATINGLY.
ENTER USER CODE YOU
WISH TO DELETE. PRESS
1 s.
GREEN + RED + BEEP 3 X 1
s. USER CODE IS DELETED.
PRESS 5 s.
BLUE IS FLASHING.
ENTER ADMIN. CODE.
PRESS .
GREEN + BEEP 1 s.
GREEN AND RED ARE
FLASHING ALTERNATINGLY.
ENTER OLD ADMIN. CODE,
PRESS 1 s.
GREEN + BEEP 1 s.
BLUE IS FLASHING.
ENTER NEW ADMIN. CODE
4 - 16 NUMBERS.
PRESS 1 s.
GREEN + BEEP 1 s.
NEW ADMIN. CODE IS
SAVED.
DELETE ENTIRE BASE
PRESS AND 10 s.
BLUE + RED ARE FLASHING
ALTERNATINGLY.
ENTER ADMIN. CODE AND
PRESS .
BLUE + RED + BEEP 5 X 1 s.
ENTIRE CODE BASE IS
DELETED.
8
EN
Table of contents