Starting
After checking to make sure that all the tubes have been adequately sealed, that the
power supply cable has been connected to its attachment and the gun is in the rest
position, the pump can be started.
After inserting the suction tube in the tank and the gun in the filling hole, switch on the
pump, gradually release the gun’s lever and begin the transfer of the Diesel oil.
WARNINGS
It is absolutely prohibited to abandon the pump while filling in order to prevent the potential
overflow of Diesel oil.
Never start the pump before first connecting the suction and delivery tubes.
After closing the gun, switch off the motor pump as quickly as possible.
It is absolutely prohibited to use the pump with your hands wet, barefoot or while standing
in water.
WARNING: The use of batteries of adequate capacity that are not sufficiently charged
creates decreased pump speed, reduced flow, and insufficient suction that may lead to the
lack of suitable Diesel oil flow.
ASSEMBLY AND DISASSEMBLY
The motor pump has no separate accessories and therefore does not require assembly.
The motor must be disassembled only and exclusively at authorized assistance centers or
by qualified technicians.
MECHANICAL RISKS
Risks created by extreme surrounding temperature.
Remember that excessively low temperature (-30℃) can freeze the diesel oil inside the
pump and that this can cause serious damage to all parts of the motor pump.
Excessively high temperature (40℃in the shade) can cause the sagging or dilatation
of the unit’s plastic parts. We recommend fastening the unit in a well-ventilated area
protected from direct sunlight.
MAINTENANCE AND TROUBLE SHOOTING
Maintenance operations can be performed only after first disconnecting the power supply
plug. The motor pump does not require any special maintenance inside, and for this
reason must never be disassembled. It is important to keep the suction and
deliverysections perfectly clean and free from all clogging.
TROUBLESHOOTING
12V DIESEL FUEL TRANSFER DISPENSER PUMP
CT5261
Technical Specifications:
Voltage: 12V (DC)
Power: 175W
Load current: 10Amps
Flowing: 45L/Min
Head: 7m
Suction: 3m
Inlet /Outlet diameter: 3/4"
CAUTION: Please read this manual carefully before operating the pump!
PROBLEMS
CAUSES
SOLUTIONS
The pump
fails to turn
No power supply
Impeller jammed
Motor malfunction
Check the clamps and the safety
devices.
Disassemble, check for signs of
damage or clogging. Reassemble.
Contact your local dealer.
Low pump
flow.
Tank liquid level too low.
By-pass valve jammed.
Filter clogged.
Air in the suction tube.
Decreased pump rotation speed.
Leakage of Diesel oil.
The suction tube is resting on the
bottom of the tank.
Excessive suction height.
Fill up the tank.
Clean and re-assemble.
Clean the filter.
Make sure that the suction tube is
not damaged.
Check and correct pump voltage.
Check the connectors and
gaskets.
Raise the tube in the tank.
Lower the level of the pump.
EC DECLARATION OF CONFORMITY
We CANNON TOOLS LTD
20 Station road, Rowley Regis, West Midlands,B65 0JU.U.K.
Declare that the following machine complies with the appropriate basic safety and
health requirements of the EC Directive based on its design and type, as brought
into circulation by us.
In case of alteration of the machine, not agreed upon by us, this declaration will
lose its validity.
Product description : 12V DIESEL FUEL TRANSFER DISPENSER PUMP
Model: CT 5261
Applicable EC Directives:
EC Machinery Directive 2006/42/EC
EC Low Voltage Directive 2014/35/EU
EC Directive of Electromagnetic Compatibility 2014/30/EU
Harmonized standards:
EN ISO 12100, EN 60335-1, EN 60335-2-41, EN 55014-1,
EN 55014-2, EN 61000-3-2, EN 61000-3-3, EN 61000-6-1, EN 61000-6-3
20 Station Road, Rowley Regis, West Midlands, B65 0JU.U.K.
Mr. Gurcharan Tony Singh Sanghera
Managing Director
CANNON TOOLS LTD
2019-12-04
Warning
•The user must absolutely observe the accident-prevention measures in force, and must
also respect the indications provided in the following chapters.
•Never shift the motor pump during operation for any reason whatsoever.
•Before using the motor pump, always make sure that the power supply cable and all the
other devices are in perfect working condition.
•Before starting the motor pump, make sure that you are not barefoot, that your hands are
not wet, and that you are not even partially standing in water.
•The motor pumps are constructed in such way that all the moving parts are protected by
casings. Never remove any of these casings when the motor pump is running for any
reason whatsoever.
•It is very important to keep the motor pumps’ power socket protected from sprays of water,
rain and atmospheric agents in general and all the other liquids.
•Not for use with gasoline or alcohol.
•Not for use in hazardous locations.
•Improper use or installation of this product can cause serious bodily injury or death.
• Do NOT smoke near pump or use pump near an open flame.
• Do not use this product for fluid transfer into aircraft.
• This product is not suited for use with fluids for human consumption or fluids containing
water.
• Do not dispense fluid that is thicker than diesel fuel. Motor may overheat.
SAFETY INSTRUCTIONS
To ensure safe and efficient operation, it is essential to read and follow each of these warnings
and precautions.
1. Disconnect power to pump before servicing pump.
2. A diesel compatible filter should be used on pump outlet to ensure that no foreign material is
transferred to fuel tank.
3. Tank or barrel should be anchored to prevent tipping in both the full and empty conditions.
4. The pump should never be left running unattended.
HANDING AND TRANSPORT
Unpacking
Whenever the packaging appears to have been damaged, check the motor pump for signs of
damage during transport of handling.
WARNING: Before installing and using the motor pump, check the identification plate to make
sure that the model and its characteristics correspond to those specified.
Handling disassembly and transport
Although the reduced size and weight of the motor pump will not create particular problems in
transport, we recommend the following:
Never move the motor pump for any reason without first unplugging the power supply plug from
the socket or disconnecting the electrical power supply.
Unscrew and remove the delivery and suction tubes.
Unscrew the bolts or screws used to anchor the motor pump in place.
Never move or drag the motor pump by pulling its power supply cable.
USE AND STARTING
Electrical power supply connection:
Before using, first make sure pump is to use DC power or AC power.
If the pump’s power is DC power:
(1)Connect the pump’s clamps to a battery capable of delivering the current and voltage
required for the operation of the pump.
(2)If a motor vehicle battery is used to power the pump, we recommended first removing it from
the vehicle and standing it on a stable surface in a comfortable position.
(3)The pump can be connected to a battery mounted in a motor vehicle only if the vehicle is
parked outdoors and only if the pumps’ electrical cables and connection piping are long enough
to provide the pump with solid support.
(4)The use of extension cords for the electric cables connected to the clamps is prohibited .If
the length of the cables supplied with the machine is not sufficient to power the pump, the
clamps must be substituted with jack plugs of adequate section by a specialized electrician.
(5)The pump can be connected to a battery-charger only of adequate power equipped with
terminals, never make connections to clamps coming from the battery charger and connect the
pumps’ clamps directly to the battery charger’s terminals in order to prevent the generation of
sparks that might cause fires.
(6)Make sure that the voltage of the pump (indicated on the identification plate) corresponds to
the voltage of the battery.
(7)Make to always respect polarity: connect the black clamps to the - pole and the red clamps to
the + pole.
Be extremely careful (when connecting the pump to the battery) to avoid making contact
between opposite poles and creating sparks (which can cause fire). We recommend connecting
the negative pole first and then the positive pole.
(8)Position the pump securely and make sure that the lengths of both the power supply cables
and the piping are sufficient to ensure solid positioning.
If the pump’s power is AC power:
(1) Power overload current protection switch must be installed
(2) Position the pump securely and make sure that the lengths of both the power supply cables
and the piping are sufficient to ensure solid positioning.

Other Neilsen Water Pump manuals

Neilsen WWB-05806 User manual

Neilsen

Neilsen WWB-05806 User manual

Neilsen CT5261 User manual

Neilsen

Neilsen CT5261 User manual

Neilsen CT1731 User manual

Neilsen

Neilsen CT1731 User manual

Neilsen CT0848 User manual

Neilsen

Neilsen CT0848 User manual

Neilsen CT5182 User manual

Neilsen

Neilsen CT5182 User manual

Neilsen CT3793 User manual

Neilsen

Neilsen CT3793 User manual

Neilsen CT2437 User manual

Neilsen

Neilsen CT2437 User manual

Neilsen CT5183 User manual

Neilsen

Neilsen CT5183 User manual

Popular Water Pump manuals by other brands

Simer SIMER 2961 owner's manual

Simer

Simer SIMER 2961 owner's manual

JABSCO 11860-0005 manual

JABSCO

JABSCO 11860-0005 manual

Wacker Neuson PS2 1503 Operator's manual

Wacker Neuson

Wacker Neuson PS2 1503 Operator's manual

FLEXXOLUTIONS Flexxoturi user manual

FLEXXOLUTIONS

FLEXXOLUTIONS Flexxoturi user manual

Flotec 4202A Series owner's manual

Flotec

Flotec 4202A Series owner's manual

Liquiflo MAX Series Installation, operation and maintenance manual

Liquiflo

Liquiflo MAX Series Installation, operation and maintenance manual

ATI Technologies 39-0038 Control manual

ATI Technologies

ATI Technologies 39-0038 Control manual

Pfeiffer Vacuum OKTA 1000 M operating instructions

Pfeiffer Vacuum

Pfeiffer Vacuum OKTA 1000 M operating instructions

DAB E-SWIM 150 manual

DAB

DAB E-SWIM 150 manual

Onninen ONNLINE 6 Series Original instructions

Onninen

Onninen ONNLINE 6 Series Original instructions

PeriBest Pumps T05 manual

PeriBest Pumps

PeriBest Pumps T05 manual

Pfeiffer Vacuum TC 750 operating instructions

Pfeiffer Vacuum

Pfeiffer Vacuum TC 750 operating instructions

STERWINS 900 JET IC-3 manual

STERWINS

STERWINS 900 JET IC-3 manual

Pentair Jung Pumpen BASICLOGO BD 610 EC instruction manual

Pentair

Pentair Jung Pumpen BASICLOGO BD 610 EC instruction manual

Grundfos CM Smart Installation and operating instructions

Grundfos

Grundfos CM Smart Installation and operating instructions

RP Pump UVC Series operating instructions

RP Pump

RP Pump UVC Series operating instructions

Groz OPM/115 instruction manual

Groz

Groz OPM/115 instruction manual

Gardena 5500/5 inox operating instructions

Gardena

Gardena 5500/5 inox operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.