neno primo User manual

USER’S MANUAL
EN
Dear Customer,
the device Neno Primo you received is an electronic breast pump. It is used to express breast
milk aer childbirth.
Please read the instrucons before using the device.
1. SAFETY MEASURES
1. Do not use the breast pump during pregnancy – this can cause early delivery.
2. Do not use the device if you suffer from chronic diseases or oversensivity that would
make using the device painful to you.
3. Before each use of the device, make sure that no component is damaged. Do not use
a breast pump if any of its components are clearly damaged.
4. Keep the device away from children and animals.
5. For hygienic reasons, only one person should use the breast pump.
6. Keep the pumping part of the device away from water.
7. Avoid exposing the device to mechanical damage caused by, for example, dropping it.
8. Store the silicon parts of the breast pump away from hot surfaces to avoid distorng them.
9. Store only milk that has been drained using a clean and disinfected breast pump.
10. Do not clean parts of the device with abrasives.
11. Do not try to repair the breast pump yourself – this will void the warranty.
12. If the use of the device causes pain or severe discomfort, turn it off and move
the breast pump away from your breast.
13. Do not clean the tube too oen and make sure it is dry before use. A wet tube can
damage the device.
14. Do not charge the device with a voltage higher than specified in the technical
specificaon.
9
primo
2. ELEMENTS
See - Figure 1 on page 2
A. Cap
B. Breast shield 24 mm
C.Connector
D.Pumping device
E.Sucon bowl
x2F.Valve
G. Milk bole
H. Bole holder
I. Bole teat
J. Charging cable
K. Bole cap

10
3. DESCRIPTION OF MODES
Smulaon mode:
L1 - 5 kPa; L2 - 12 kPa; L3 - 17 kPa; L4 - 21 kPa ; L5 - 25 kPa ;
:Expression mode
L1 - 21 kPa; L2 - 24 kPa; L3 - 27 kPa; L4 - 31 kPa ; L5 - 37 kPa ; L6 - 40 kPa ;
L7 - 42 kPa; L8 - 43 kPa; L9 - 45 kPa;
Allowable difference is ± 5 kpa
4. DESCRIPTION OF ICONS AND BUTTONS
1. Power buon:
Hold for 2 seconds to turn the breast pump on or off.
2. Mode change:
Press the buon to change the mode. The device will automacally switch from smulaon to
expression mode aer 2 minutes. The device can save sengs and has a me counter. When you
turn on the device, the sengs from the previous use of the device are automacally turned on.
The breast pump will automacally turn off aer 30 minutes of use.
3. Sucon power:
+ increases sucon power; - reducon of sucon power (smulaon mode: L1-L5;
expression mode: L1-L9).
4. Baery status:
Indicates the amount of baery power remaining. Charge the breast pump if the baery is low.
5. Session duraon:
Indicates how long you have been using the breast pump. The device will turn off automacally aer
30 minutes of use.
E- Sucon increase
F- Sucon level
G- Expression mode
H- Session Duraon
See - Figure 2 on page 2
A- Sucon decrease
B- Smulaon mode
C- Baery Percent
D- Power buon/ mode change
5. BEFORE FIRST USE
6. CLEANING
Cleaning and sanizing are two different acvies. They must be done separately to protect
your child and ensure that the breast pump works properly.
Cleaning - washing the surface of the device and removing dirt.
Sanizing - killing organisms such as bacteria or viruses that may be present on the surface
of the device.
See - Figure 3 on page 2
1. Remove the cap from the breast shield before each use.
2. Pull down on valve toremove from connector.
3. Separate the connectorfrom the sucon bowl and sucon cap

11
Breast shield Breast pump elements
(connector, sucon cap,
sucon bowl) The bole and teat
Before first use
Aer each use
Once a day
Cleaning
Cleaning and sanizing
Sanizing
Cleaning
Cleaning and sanizing
Sanizing
Cleaning
Cleaning and sanizing
Sanizing
7. ASSEMBLING THE BREAST PUMP
1. Wash your hands thoroughly with soap and water before touching the breast pump and
breast.
2. Aach the breast shield, sucon bowl and sucon cap to the connector.
3. Place the valve in the connector and screw the milk bole onto the connector by turning
it clockwise unl it stops turning.
Tips:
a. Check the breast pump components for damage before each use. Replace damaged items
with new ones as needed.
b. Always check the cleanliness of the elements before using the machine.
c. To avoid damage to the breast pump, make sure that all its parts are dry before using it.
8. CHARGING THE BREAST PUMP
Before the first use, charge the breast pump for 2 hours by connecng it to the power supply
using the USB cable. The baery icon on the display will be full when charging is complete.
9. USING THE BREAST PUMP
See - Figure 4 on page 2
1. Place the breast shield on the breast so that the nipple is inside the drainage channel.
2. Press the breast shield and the connector to your breast, using your thumb and forefinger.
Support your chest with the palm of your hand.
3. Turn on the breast pump by pressing the power buon and select the mode of operaon
that suits you.
4. Press the power buon to turn off the breast pump aer use and place the lid on the breast
shield to protect the machine from dust.
a. The breast pump starts work in the smulaon mode. Set the sucon power to a level that
is comfortable for you using the +/- buons
Smulaon mode - fast pumping that mimics the natural sucking of breast milk by a baby,
smulang milk flow.
b. Aer 2 minutes, the breast pump will automacally acvate the expression mode. Adjust
the level of sucon using the +/- buons to find the highest level of sucon that is
comfortable for you. If milk begins to flow out of your breast before two minutes pass, press
the mode buon to manually switch to the expression mode.

12
10. FAQ
1. The machine does not start: ensure that the breast pump is connected to a working
electrical outlet. If the breast pump has no power source, its display will not turn on and
no error message will appear.
2. No/ poor sucon: make sure all parts of the breast pump are correctly posioned.
Disassemble the breast pump and make sure that all parts are clean and undamaged.
Assemble the breast pump again according to the instrucons in secon „Assembling the
breast pump”.
3. More milk has flowed out of the breast than the bole can hold: switch off the breast
pump and unplug it. Use a damp (not wet) cloth to wipe the breast pump. When all parts
of the device are dry, reassemble them.
Expression mode - slower pumping which gently and efficiently sucks breast milk.
c. In the expression mode, increase the sucon power unl you feel slight discomfort
(not pain) and reduce the sucon power by one degree.
11. LONG-TERM STORAGE
1. The breast pump has a built-in baery. To protect against damage, the device goes into
storage mode aer a long period of inacvity. To turn off storage mode, connect the device
to power and charge it for 2 hours.
2. Before pung the breast pump away for a longer period of me, make sure that:
a. All parts of the breast pump are clean.
b. You have cleaned the pumping device.
c. The device's baery is fully charged.
12. CLEANING INSTRUCTIONS
Prepare: mild soap or other cleaning agent, clean dish towel, drinking-quality water.
Parts that need to be washed or disinfected:
- Breast shield,
- Milk bole,
- Connector,
- Valve,
- Sucon cup,
- Sucon bowl,
- Breast shield dust cap.
WARNING:
- Wash all parts that have had direct contact with breast milk immediately aer use. This
helps you will avoid residue and the growth of bacteria in the device.
- Use only drinking-quality water (tap or boled) to clean the appliance.
- When cleaning valves, do not use small instruments such as brushes. Be careful not to pierce
the part.
- Disassemble, wash and rinse all parts of the device that have come into direct contact with
breast milk (except for the pump).

13
1. Cleaning the breast pump components (Before first use and aer each use):
Step 1 - Disassemble the device and rinse all parts that have come into contact with the
breast and milk in cold water to get rid of the remains of milk and any residue.
Step 2 - Soak in warm, soapy water for 5 minutes, then wash and rinse
Step 3 - Let the parts air dry. Store dry device parts in a cool and dry place when you're not
using them.
minute
5
minutes
10
2. Sterilizaon of the breast pump components (before first use and aer use):
Step 1 - Fill the pot with enough water to cover all parts of the disassembled appliance.
Bring the water to a boil before you put the unfolded breast pump inside.
Step 2 - Place the parts of the device in boiling water for 10 minutes.
Step 3 - Let the parts air dry. Store dry device parts in a cool and dry place when you're not
using them.
Prepare:
-mild soap or other cleaning agent,
-clean dish towel.
Parts that need to be cleaned:
-pumping device.
3. Cleaning the pumping device:

14
13. SPECIFICATION
Output power: 110-240V 50-60Hz
Input power: 5V 1A
Weight: 357 g
Dimensions: 84x64x63 mm
Baery capacity and type: 3.7V 1400 mAh Li-Ion
WARNING:
- Do not submerge the pumping device in water.
- Do not rinse the pumping device with water.
- When cleaning the display of the pumping device, use only a damp, so cloth with
a mild soap or cleaner. Stronger cleaning products or abrasive materials can destroy
the display.
14. WARRANTY CARD/ COMPLAINTS
The product is covered by a 24-month warranty.
The terms of the guarantee can be found at: hps://neno.pl/gwarancja
Details, contact and website address can be found at: hps://neno.pl/kontakt
Specificaons and contents of the kit are subject to change without noce.
We apologise for any inconvenience.
Manufacturer:
KGK Trade sp. z o.o. sp. k.
Ujastek 5b,
31-752 Cracow
Poland
Made in P.R.C.
www.neno.pl
inspired by Children,
designed by Parents
Table of contents
Other neno Breast Pump manuals