Nera Saturn B User manual

Standard
• Charge Tone
• Traffic Log
• Access Code
Optional
• Precharge
• Restricted LES
• Restricted Dialing
• Cryptophone STUIII/STUIIB
• Credit Card Phone
Saturn B/M Enhanced Functions
Operator’s Manual


Saturn B/M Enhanced Functions – Operator’s Manual
Chapter 1. Introduction
About Enhanced Functions ...................... 1.1
Protection ................................................. 1.2
Renter/Owner Level ................................. 1.3
Password ................................................. 1.5
Chapter 2. Standard
Charge Tone ............................................ 2.1
Traffic Logging ......................................... 2.3
Access Code .......................................... 2.13
Chapter 3. Optional
Precharge ................................................. 3.1
Restricted LES ......................................... 3.3
Restricted Dialing ..................................... 3.4
Cryptophone STU III and STU IIB ............ 3.5
Credit Card Phone ................................... 3.6
APPENDIX –
Overview of Functions
1. Introduction
2. Standard
3. Optional
Appendix
5. Appendices
Doc. No. QLZB911016 Rev. B Copytema 5156 02/98
Nera SatCom AS reserves the right to change the design
and specifications of the equipment without notice.


Saturn B/M Enhanced Functions – Chapter 1. Introduction
Contents
About Enhanced Functions ........................................................ 1.1
Protection ................................................................................... 1.2
Renter/Owner Level .................................................................... 1.3
Password .................................................................................... 1.5
Chapter 1. Introduction
Nera SatCom AS reserves the right to change the design
and specifications of the equipment without notice.


Saturn B/M Enhanced Functions – Chapter 1. Introduction
1.1
About Enhanced Functions
About Enhanced Functions
Standard Enhanced Functions
The following Enhanced Functions are available as standard for
Saturn B and Saturn M terminals:
•Charge tone, which sends a tone on selected telephone ports
when charging starts.
•Traffic log, which logs traffic data from selected telephone ports
and provides detailed printout.
•Access code, which allocates a personal 1-8 digit code to up to
100 authorized users. The code opens the system for one call.
Optional Enhanced Functions
The Enhanced Functions below are available as options:
•Precharge, which allows preprogramming the Saturn M or B
terminal with a maximum total call duration. The maximum call
duration can be extended by the owner.
•Restricted LES, which allows the owner to lock the terminal to
one specific LES per Ocean Region.
•
Restricted Dialing, which allows calls to preset short numbers only.
•STU III and STU IIB, which prepares selected port(s) for use with
encrypted telephone.
•Credit Card Phone, which prepares selected port(s) for use with
credit card telephone.
Activation of these functions requires individual opening keys pro-
vided when purchasing the functions.
Optional Data and Telex Functions
Data link and telex functions are also available as options:
•
High Speed Data, HSD, which offers 56/64 kbps full duplex or sim-
plex link with terrestrial ISDN networks (Saturn B only).
•
Asynchronous Data, ASD, which offers data transmission at
2.4 kbps (Saturn M) or 9.6 kbps (Saturn B) via its built-in modem.
•
Telex, simplex and duplex (Saturn B only).
See separate manuals.
Installation
Enhanced Functions are activated using the "Enhanced Setup"
function no. 89.
Only Enhanced Functions that have been activated are listed when
searching through the main menu "Enhanced Functions" no.8.
Functions that are not yet activated appear as "PASSIVE" when
opening the "Enhanced Setup" function no.89.
See appendix for an overview of Saturn B/M functions.

Saturn B/M Enhanced Functions – Chapter 1. Introduction
1.2
Protection
ON
OWN.
RENT. OPER.
SETUP OPEration
UPDATE OPEration VIEW OPEration
Protection
General
Two password protected user levels are provided in addition to USER
and OPERATOR level:
•RENTER, and
•OWNER
A common default password (1 2 3 4 5 6) facilitates the activation of
Enhanced Functions for new users (see "Password").
Warning! An individual OWNER password must be entered to protect
the equipment against unauthorized use. The password must be
stored in a safe place.
For safety purposes, protect all telephone ports, see "Access Code".
Up to three different operation rights can be assigned with selecta-
ble access level to each Enhanced Function:
• SETUP OPERATION – allows such as selection of ports.
Default access level: OWNER.
• UPDATE OPERATION – such as entering/deletion of data.
Default access level: OWNER.
• VIEW OPERATION – such as display readout and printout.
Default access level: OPERATOR
When activating a function, the access level required to operate each
right can be seen in the display when pressing MORE/HELP.
See example below.
Setup operations can be accessed from RENTER or OWNER level
only.

Saturn B/M Enhanced Functions – Chapter 1. Introduction
1.3
General
The Saturn M/B terminals provide the following access levels in
addition to USER (1) level and OPERATOR (2) level:
•RENTER (3), and
•OWNER (4)
The RENTER and OWNER levels are protected by passwords.
The default password for both levels is 1 2 3 4 5 6.
Password protection can be used to restrict operative functions to
different parameter levels, e.g.:
• level 4 (OWNER) allowed to change setup.
• level 3 (RENTER) allowed to read data.
• level 2 (OPERATOR) given no access to reading or setup.
• level 1 (USER) has standard minimum operational functions.
These restrictions can be applied according to function, e.g.:
The RENTER level can be allowed to configure the traffic log, but
restricted to reading only in the access code function.
An individual password may be assigned to each level using the "SET
PASSWORD" function no.13, see "Password".
To Set Access Level:
1Select SET USER
LEVEL function (12):
2Display the current level:
3Key in operator level ref. number,
e.g. 3 (RENTER):
3=RENTER, 4=OWNER
4Key in the current password for this
level (the default password
is 1 2 3 4 5 6):
5
The terminal is now set to RENTER LEVEL:
This level is active until a new level is set or the
terminal is switched off. Therefore, set the level
back to USER when finished with your operations.
and revert to IDLE:
Renter/Owner Level
ON
SET USER
LEVEL
12
ENTER
FUNC
ON
LEVEL:
USER
1
ABC
ENTER
2
DEF
PLAY
ON
LEVEL:
?
3
GHI
ENTER
ON
LEVEL:
RENTER
ON
PASSWORD
?
ENTER
ESC
3x
2
DEF
PLAY
1
ABC
6
PQR
4
JKL
5
MNO
3
GHI
Renter/Owner Level

Saturn B/M Enhanced Functions – Chapter 1. Introduction
1.4
Renter/Owner Level Cont’d
Optional Functions
When purchasing one or a set of Optional Enhanced Functions, an
"Opening Key" will be provided that cause the function(s) to be in-
stalled. Proceed as under "To Set Access Level":
1Select SET USER LEVEL function (12)
2Display current level
3At the "LEVEL" prompt, key in 5 9 6.
4At the "PASSWORD" prompt, key in the "Opening Key" provided
by the agent.
The function(s) are now installed.
5Activate the function using the ENHANCED SETUP function (89)
described later in this manual.
Renter/Owner Level Cont’d

Saturn B/M Enhanced Functions – Chapter 1. Introduction
1.5
General
The RENTER and OWNER levels are protected by passwords.
The default password for both user levels is 1 2 3 4 5 6.
The password may be changed individually to any password contain-
ing at least 4 digits. The owner may change password for both OWN-
ER level and RENTER level, whilst the renter may change password
for the renter level only.
Setting Passwords from OWNER level
1Select SET PASSWORD
function (13):
2Display current level (OWNER):
Note! Pressing MORE/HELP reveals a
restore code
that allows the password
to be reset to default: 1 2 3 4 5 6.
See "Regaining RENTER Default
Password"on next page.
3Select required level, e.g. 3:
3=RENTER, 4=OWNER
4Key in new RENTER
password, e.g. 1 2 3 4 :
Minimum 4 digits
5Verify RENTER password:
6Select required level, e.g. 3:
3=RENTER, 4=OWNER
7Key in new OWNER
password, e.g.1 2 3 4 5:
8Verify the OWNER
password:
and revert to IDLE:
Password
FUNC
1
ABC
3
GHI
4
JKL
1
ABC
2
DEF
PLAY
3
GHI
4
JKL
1
ABC
2
DEF
PLAY
3
GHI
4
JKL
5
MNO
4
JKL
1
ABC
2
DEF
PLAY
3
GHI
5
MNO
4
JKL
1
ABC
2
DEF
PLAY
3
GHI
3
GHI
MORE/
HELP
ON
SET
PASSWORD
13
ON
CURR. LEVEL:
OWNER
ON
999 PASSWORD
03945723
ON
PASSWORD FOR
3
ENTER
ENTER
ESC
3x
ON
NEW PASSWORD
?
ON
VERIFY
?
ON
PASSWORD FOR
4
ENTER
ON
NEW PASSWORD
?
ON
VERIFY
?
ENTER
ENTER
ENTER
ENTER
Password

Saturn B/M Enhanced Functions – Chapter 1. Introduction
1.6
Password Cont’d
Setting Password from RENTER Level
The procedure below assumes that the Saturn terminal is set in
RENTER access level, see "Renter/Owner Level".
1Select SET PASSWORD
function (13):
2Current level:
3Key in new RENTER
password, e.g. 1 2 3 4 :
4
Verify RENTER password:
The verified password is correct:
Revert to IDLE:
Regaining Default RENTER Password
If accidentally losing the password, it can be reset to the default
password 1 2 3 4 5 6.
Proceed as under "Renter/Owner Level: To Set Access Level".
1Select SET USER LEVEL function (12).
2
Display current level.
3At the "LEVEL" prompt, key in 9 9 9.
4At the "PASSWORD" prompt, key in the restore code provided by
the agent.
5The RENTER password is now reset to default password
1 2 3 4 5 6.
Regaining Default OWNER Password
The OWNER password is reset to default value as described above,
except that the restore code must be provided by the manufacturer.
FUNC
ON
1
ABC
3
GHI
SET
PASSWORD
13
4
JKL
1
ABC
2
DEF
PLAY
3
GHI
ENTER
4
JKL
1
ABC
2
DEF
PLAY
3
GHI
ENTER
ON
PASSWORD FOR
RENTER
ESC
3x
ENTER
ON
PASSWORD FOR
RENTER
ENTER
NEW PASSWORD
ON
VERIFY
ON
Password Cont’d

Saturn B/M Enhanced Functions – Operator’s Manual
Contents Chapter 2. Standard
Charge Tone ............................................................................... 2.1
Traffic Logging ............................................................................ 2.3
Access Code ............................................................................ 2.13
Nera SatCom AS reserves the right to change the design
and specifications of the equipment without notice.


Saturn B/M Enhanced Functions – Chapter 2. Standard 2.1
Charge Tone
General
Each telephone port can be programmed to send a tone when the
remote end subscriber answers and charging commences, for use
with a card telephone or other debiting systems.
To avoid unauthorized use, setting of the function can be protected by
means of two password levels: "Renter/Owner Level".
Frequency and length of the charge tone is set with function no. 80,
see next page (the same tone is sent on all ports selected).
Selection of ports to send charge tone is made with function no. 89, see below.
Selecting Ports to Send Charge Tone
1Select ENHANCED
SETUP function (89):
2Check which ports are currently
selected, e.g. TEL.3 and TEL.5:
If no ports are set:
Current operation status (all
operations require OWNER level):
If PASSWORD PROTECTED, refer
to "Renter/Owner Level".
3
Change selection to ports TEL.1 and 4:
0=handset, 1-5=connectors TEL.1-5
(Use DEL to deselect ports)
4Assign operation access level, e.g. 3:
2=operator (OPER), 3=renter (RENT)
4=owner (OWN)
5Verify settings:
and revert to IDLE:
FUNC
ON
MORE/
HELP
9
LIGHT
YZÆ
8
VWX
TAX
1
ABC
4
JKL
3
GHI
ENHANCED
SETUP
89
ON
CHARGE TONE
PORTS: 35
ON
CHARGE TONE
PASSIVE
ON
OWN.
– –
ON
SETUP OPE.
3
ON
WHICH PORTS
14
ENTER
ENTER
ENTER
ON
CHARGE TONE
PORTS: 14
ENTER
ON
RENT.
– –
ESC
3x
MORE/
HELP
MORE/
HELP
p
Charge Tone

Saturn B/M Enhanced Functions – Chapter 2. Standard2.2
Charge Tone Cont’d
Frequency and Length
1Select CHARGE
TONE SETUP function (80):
2
Check current tone frequency and length:
3
Change frequency to
e.g. 2800 Hz:
Valid value: 400 – 3400 Hz,
or 0 –15 for selection of DTMF tones:
4
Change length to
e.g. 400 ms:
Valid value: 10 – 5000
milliseconds (0.01 – 5 seconds):
5
Verify settings:
and revert to IDLE:
FUNC
ON
8VWX
TAX
4JKL
0ÄÖÜ
8VWX
TAX
0ÄÖÜ
0ÄÖÜ
2DEF
PLAY
0ÄÖÜ
0ÄÖÜ
CHARGE TONE
SETUP
80
MORE/
HELP
MORE/
HELP
ON
FRQ: 2400
LEN: 1000
MS
ON
FREQ (HZ)
2800
ON
400 –
3400 HZ
ON
LENGTH (MS)
400
ENTER
ENTER
ENTER
ESC
3x
ENTER
ON
10 –
5000 MS
ON
FRQ: 2800
LEN: 400
MS
Charge Tone Cont’d

Saturn B/M Enhanced Functions – Chapter 2. Standard 2.3
Traffic Logging
General
Each telephone port can be configured for logging of the following
data:
• Destination address (B subscriber’s number)
• Date and time of call
• Call duration
• LES used
• User ID (to code protected ports only,
see "Access Code".)
• Port designation
To avoid unauthorized use, the function can be protected by password
levels:
see "Renter/Owner Level"
.
The following tasks can be allocated:
• SETUP OPE. –
selection of ports to be logged, and clearing of logs.
(default access level: OWNER).
• UPDATE OPE. – defining levels that can delete and flush logs
(default access level: OWNER).
• VIEW OPE. – reading and printout of logs
(default access level: OPERATOR)
Setting of ports to be logged and access levels is made with the "En-
hanced Setup" function no. 89,
see "Selecting Ports and Access
Level" on next page.
Shortcut
For daily routine, you may print out the traffic log using the shortcut
SHIFT + PLAY:
This will print and flush the time log,
see "TIME Log Output".
Make sure that the user level is appropriate.
Traffic Logging
SHIFT
2
DEF
PLAY
DIAL 00+INTL
TEL.NO.+
ON
PRINTING
ACCEPTED
ON

Saturn B/M Enhanced Functions – Chapter 2. Standard2.4
Traffic Logging Cont’d
Selecting Ports and Access Level
1Select ENHANCED
SETUP function (89):
2
Check which ports are currently
logged, e.g. TEL.3 and TEL.5:
If no ports are logged:
Current operation status (SETUP and UPDATE
operations require OWNER level, VIEW
operation requires OPERATOR level):
If PASSWORD PROTECTED, refer
to "Renter/Owner Level".
3
Change selection
to ports HANDSET and TEL.4:
0=handset, 1-5=TEL.1 - 5, 6=DTE
(Use DEL to deselect ports)
4
Assign operation access levels, e.g.:
2=operator (OPER)
3=renter (RENT)
4=owner (OWN)
5
Verify settings:
and revert to IDLE:
FUNC
ON
MORE/
HELP
9
LIGHT
YZÆ
8
VWX
TAX
1
ABC
4
JKL
2
DEF
PLAY
0
ÄÖÜ
4
JKL
ENHANCED
SETUP
89
LIST
ON
TRAFFIC LOG
PORTS: 35
ON
TRAFFIC LOG
PASSIVE
ON
OWN.
RENT. OPER.
ON
WHICH PORTS
01
ENTER
ENTER
ENTER
ON
TRAFFIC LOG
PORTS: 04
ENTER
ON
OWN.
OWN. OPER.
ESC
3x
MORE/
HELP
MORE/
HELP
ON
SETUP OPE.
4
UPDATE OPE.
4
ON
ENTER
ENTER
VIEW OPE.
2
Traffic Logging Cont’d

Saturn B/M Enhanced Functions – Chapter 2. Standard 2.5
Traffic Logging Cont’d
Selecting Destination and Autoprint
1Select TRAFFIC
LOG SETUP function (82):
2Check current destination of flush printout,
and number calls before automatic printout:
0=no autoprintout, 1=computer formatted
printout (without heading etc.) after every call.
3Key in destination, e.g. 2 (to printer):
0=no output, 2=to printer,
3=to DTE port
(DTE is the only choice
for Saturn MiniPhone)
4Key in number of calls before printout:
1 – 100 records, 0=disabled,
1=computer formatted printout
after every call
5
Choose whether or not the user log
should be flushed automatically when full:
6
Choose whether or not the port log
should be flushed automatically when full:
Automatic flush: printout after 100 calls,
and log is reset.
Revert to IDLE:
FUNC
ON
8
VWX
TAX
1
ABC
2
DEF
PLAY
8
VWX
TAX
1
ABC
TRAFFIC LOG
SETUP
82
ON
TO PRINTER
LIMIT: 12
ON
ENABLED
DISABLED
ON
0=NO, 2=PRINT
3=DTE PORT
ENTER
ENTER
ON
1 - 100
O = DISABLED
ESC
3x
MORE/
HELP
ON
PRINT TO
2
MORE/
HELP
Autoflushing of USER log ENABLED
Autoflushing of PORT log DISABLED
ENTER
2
DEF
PLAY
ENTER
MORE/
HELP
ON
MAX ENTRIES
8
ON
AUTOFLSH USR
1
ON
AUTOFLSH PRT
1
MORE/
HELP
ON
O=DISABLED
1=ENABLED
ENTER
Traffic Logging Cont’d

Saturn B/M Enhanced Functions – Chapter 2. Standard2.6
Traffic Logging Cont’d
Traffic Log Output
The "Traffic Log" function no.81 provides three types of call logs:
•TIME LOG – which sorts all calls by date/time
•USER LOG – which sorts calls by selected user ID
•PORT LOG – which sorts calls from selected port
Each log can be output in three ways:
• VIEW – scrolling through list
• PRINT –
printout of list (without deleting printed records)
• FLUSH – print/deletion of logged data
•
VIEW HISTORY LOG
– which lists the 100 last calls (also the data
that have been FLUSHED).
Selection of logs is made as follows:
1Select TRAFFIC
LOG function (81):
2
Select TIME LOG (A):
(sorted by date/time)
See "TIME Log Output" for
further information.
3
Select USER LOG (B):
(sorted by User ID)
See "USER Log Output" for
further information.
4
Select PORT LOG (C):
(sorted within selected end terminal)
See "PORT Log Output" for
further information.
Deleting Traffic Log Data
Deletion of all traffic log data can only be achieved when in OWNER level:
1Select TRAFFIC LOG function (81):
2
Press and hold the DEL key:
and
press the Y-key to delete traffic logs:
FUNC
ON
8
VWX
TAX
LIST
LIST
1
ABC
TRAFFIC LOG
81
ON
TIME LOG
A
ENTER
ON
USER LOG
B
ON
PORT LOG
C
FUNC
ON
8
VWX
TAX
1
ABC
9
LIGHT
YZÆ
DEL
TRAFFIC LOG
81
ON
DELETE ?
Y= YES
81
ALPHA
Traffic Logging Cont’d
Other manuals for Saturn B
2
This manual suits for next models
1
Table of contents
Other Nera Touch Terminal manuals