D-Net 8550TM USER MANUAL 9
TECHNICAL DATA
Max. lateral length - 10% flow variation
Inlet pressure: 3.0 bar
Slope
Distance between sprinklers (m)
910 11 12 13
Max. lateral length (m)
Uphill 2% 180 190 198 204 208
1% 216 220 242 252 260
Flat terrain 0 252 270 286 300 312
Downhill -1% 279 300 319 348 364
-2% 306 330 352 384 403
Nozzle size
2.3 + 1.8,
510 l/h*
Lateral: FlexNet™ 2" ID: 51.5 mm Lateral: FlexNet™ 3" ID: 78.3 mm
Slope
Distance between sprinklers (m)
910 11 12 13
Max. lateral length (m)
Uphill 2% 171 180 187 192 195
1% 198 210 220 228 247
Flat terrain 0 234 250 264 276 299
Downhill -1% 261 280 297 312 338
-2% 279 300 330 348 364
Nozzle size
2.5 + 1.8,
580 l/h*
Slope
Distance between sprinklers (m)
910 11 12 13
Max. lateral length (m)
Uphill 2% 162 170 176 180 195
1% 180 190 209 216 221
Flat terrain 0 207 220 242 252 260
Downhill -1% 234 250 264 288 299
-2% 252 270 286 312 325
Nozzle size
2.9 + 1.8,
680 l/h*
Slope
Distance between sprinklers (m)
910 11 12 13
Max. lateral length (m)
Uphill 2% 144 160 165 168 182
1% 171 180 187 192 208
Flat terrain 0 189 200 209 228 234
Downhill -1% 207 220 242 252 273
-2% 225 240 253 276 286
Nozzle size
3.2 + 1.8,
810 l/h*
Slope
Distance between sprinklers (m)
910 11 12 13
Max. lateral length (m)
Uphill 2% 135 150 154 156 169
1% 153 160 176 180 195
Flat terrain 0 171 180 198 204 221
Downhill -1% 189 200 220 228 247
-2% 198 220 231 252 260
Nozzle size
3.5 + 1.8,
940 l/h*
Slope
Distance between sprinklers (m)
910 11 12 13
Max. lateral length (m)
Uphill 2% 126 130 143 144 156
1% 135 150 154 168 169
Flat terrain 0 153 160 176 180 195
Downhill -1% 162 180 187 204 208
-2% 180 190 198 216 234
Nozzle size
3.5 + 2.5,
1135 l/h*
Slope
Distance between sprinklers (m)
910 11 12 13
Max. lateral length (m)
Uphill 2% 117 130 132 144 143
1% 135 140 143 156 169
Flat terrain 0 144 150 165 168 182
Downhill -1% 153 170 176 192 195
-2% 162 180 187 204 208
Nozzle size
4.0 + 2.5,
1275 l/h*
Slope
Distance between sprinklers (m)
910 11 12 13
Max. lateral length (m)
Uphill 2% 252 260 264 276 273
1% 369 380 396 408 416
Flat terrain 0 522 560 594 636 663
Downhill -1% 648 700 759 804 858
-2% 738 440 473 504 455
Nozzle size
2.3 + 1.8,
510 l/h*
Slope
Distance between sprinklers (m)
910 11 12 13
Max. lateral length (m)
Uphill 2% 252 260 264 264 273
1% 351 360 374 396 403
Flat terrain 0 486 520 550 576 611
Downhill -1% 594 640 693 732 780
-2% 675 730 781 456 481
Nozzle size
2.5 + 1.8,
580 l/h*
Slope
Distance between sprinklers (m)
910 11 12 13
Max. lateral length (m)
Uphill 2% 243 250 253 264 260
1% 324 340 352 372 377
Flat terrain 0 441 470 495 528 559
Downhill -1% 531 570 616 648 689
-2% 594 650 693 744 442
Nozzle size
2.9 + 1.8,
680 l/h*
Slope
Distance between sprinklers (m)
910 11 12 13
Max. lateral length (m)
Uphill 2% 234 240 242 252 260
1% 297 320 330 348 351
Flat terrain 0 396 420 451 468 494
Downhill -1% 468 500 539 576 611
-2% 522 570 605 648 689
Nozzle size
3.2 + 1.8,
810 l/h*
Slope
Distance between sprinklers (m)
910 11 12 13
Max. lateral length (m)
Uphill 2% 216 230 231 240 247
1% 279 300 308 324 338
Flat terrain 0 360 380 407 432 455
Downhill -1% 423 450 484 516 546
-2% 468 510 550 588 624
Nozzle size
3.5 + 1.8,
940 l/h*
Slope
Distance between sprinklers (m)
910 11 12 13
Max. lateral length (m)
Uphill 2% 207 220 220 228 234
1% 261 270 286 300 312
Flat terrain 0 315 340 363 384 403
Downhill -1% 369 400 429 456 481
-2% 405 440 473 504 533
Nozzle size
3.5 + 2.5,
1135 l/h*
Slope
Distance between sprinklers (m)
910 11 12 13
Max. lateral length (m)
Uphill 2% 198 210 220 216 234
1% 243 260 275 288 299
Flat terrain 0 297 320 341 360 377
Downhill -1% 342 370 396 420 442
-2% 378 400 440 468 494
Nozzle size
4.0 + 2.5,
1275 l/h*
*Nominal flow rate at 2.5 bar working pressure.