netvox RB02C User manual

Model: RB02C
Wireless 3-Gang Push Button
Wireless 3-Gang Push Button
RB02C
User Manual
Copyright© Netvox Technology Co., Ltd.
This document contains proprietary technical information which is the property of NETVOX Technology.
It shall be maintained in strict confidence and shall not be disclosed to other parties, in whole or in part, without written permission of
NETVOX Technology. The specifications are subject to change without prior notice.

1
Table of Content
1. Introduction ........................................................................................................2
2. Appearance......................................................................................................... 2
3. Main Feature....................................................................................................... 3
4. Set up Instruction................................................................................................ 4
5. Data Report......................................................................................................... 5
6. Installation..........................................................................................................9
7. Important Maintenance Instruction..................................................................10

2
1.Introduction
RA02C is the Class A device based on the LoRaWAN protocol of Netvox.
RB02C, a smart wall switch, is a long-distance trigger device.
According to the needs of different scenarios, press the trigger button of RB02C, and the device will immediately send the trigger
information to the gateway. RB02C is compatible with the LoRaWAN protocol. The device has three trigger buttons.
LoRa Wireless Technology:
LoRa is a wireless communication technology dedicated to long distance and low power consumption. Compared with other
communication methods, LoRa spread spectrum modulation method greatly increases to expand the communication distance. Widely
used in long-distance, low-data wireless communications. For example, automatic meter reading, building automation equipment,
wireless security systems, industrial monitoring. Main features include small size, low power consumption, transmission distance,
anti-interference ability and so on.
LoRaWAN:
LoRaWAN uses LoRa technology to define end-to-end standard specifications to ensure interoperability between devices and gateways
from different manufacturers.
2.Appearance
Function Key
Snap-fit Joint
Indicator
Button2
Button3
Button1

3
3.Main Feature
⚫Adopt SX1276 wireless communication module
⚫2 AAA size batteries(1.5V/ section)series power supply
⚫Press the smart switch button to send trigger information to the gateway
⚫Compatible with LoRaWANTM Class A
⚫Frequency hopping spread spectrum technology
⚫Configuration parameters can be configured via a third-party software platform, data can be read and alerts can be set via SMS text
and email (optional)
⚫Applicable to third-party platforms: Actility/ThingPark, TTN, MyDevices/Cayenne
⚫Low power consumption and long battery life
Note:
Battery life is determined by sensor reporting frequency and other variables.
Please refer to web: http://www.netvox.com.tw/electric/electric_calc.html
In this website, users can find battery lifetime for various models at different configurations.

4
4.Set up Instruction
On/Off
Power on
Insert batteries. (users may need a screwdriver to open the cover)
Turn on
Press the function key till seeing one green indicator flash and one red indicator flash.
Turn off (Restore to original setting)
Press and hold the function key for 5 seconds till green indicator flashes 20 times.
Power off
Remove Batteries.
Note
1. Remove and insert the battery; the device is at off state by default.
2. On/off interval is suggested to be about 10 seconds to avoid the interference of capacitor
inductance and other energy storage components.
3. After insert batteries and press any button, the device will be in engineering test mode.
Network Joining
Never joined the network
Turn on the device to search the network to join.
The green indicator stays on for 5 seconds: success
The green indicator remains off: fail
Had joined the network
(not at factory setting)
Turn on the device to search the previous network to join.
The green indicator stays on for 5 seconds: success
The green indicator remains off: fail
Fail to join the network
Suggest to check the device verification information on the gateway or consult your platform
server provider.
Function Key
Press and hold for 5 seconds
Restore to factory setting / Turn off
The green indicator flashes 20 times: success
The green indicator remains off: fail
Press once
The device is in the network: green indicator flashes once and sends a report
The device is not in the network: green indicator remains off
The time of pressing the alarm button
exceeds the default
The device is in the network: red indicator flashes once and sends a report
The device is not in the network: red indicator remains off
Note: If the button of the device is kept pressed that leads to exceeding the set value, the device
will automatically send the data packet and flash once whether the button is released or
not.

5
Sleeping Mode
The device is on and in the
network
Sleeping period: Min Interval.
When the reportchange exceeds setting value or the state changes: send a data report according
to Min Interval.
Low Battery Voltage Threshold
Low Voltage
2.4 V
5.Data Report
After power on, the device will immediately send a version packet report and a data report including the voltage and button status.
The device sends data according to the default configuration before any other configuring.
Report MaxTime: Max Interval =3600s
Report MinTime: Min Interval =3600s
Default reportchange:BatteryvoltageChange ---- 0x01(0.1V)
Note:
1. The cycle of the device sending the data report is according to the default.
2. The interval between two reports must be the MinTime.
The data parsing that is reported by the device please refer to
Netvox LoraWAN Application Command document and Netvox Lora Command Resolver
http://www.netvox.com.cn:8888/page/index
Report configuration and sending period are as following:
Min Interval
(Unit: second)
Max Interval
(Unit: second)
Reportable Change
Current Change≥
Reportable Change
Current Change<
Reportable Change
Any number between
1~65535
Any number between
1~65535
Can not be 0.
Report
per Min Interval
Report
per Max Interval

6
Example of ConfigureCmd
FPort:0x07
Bytes
1
1
Var(Fix =9 Bytes)
CmdID
DeviceType
NetvoxPayLoadData
CmdID–1 byte
DeviceType–1 byte –Device Type of Device
NetvoxPayLoadData–var bytes (Max=9bytes)
Description
Device
Cmd
ID
Device
Type
NetvoxPayLoadData
ConfigReport
Req
RB02C
0x01
0x A7
MinTime
(2bytes Unit: s)
MaxTime
(2bytes Unit: s)
BatteryChange
(1byte Unit: 0.1v)
Reserved
(4Bytes, Fixed 0x00)
ConfigReport
Rsp
0x81
Status
(0x00_success)
Reserved
(8Bytes, Fixed 0x00)
ReadConfig
ReportReq
0x02
Reserved
(9Bytes, Fixed 0x00)
ReadConfig
ReportRsp
0x82
MinTime
(2bytes Unit: s)
MaxTime
(2bytes Unit: s)
BatteryChange
(1byte Unit: 0.1v)
Reserved
(4Bytes, Fixed 0x00)
(1)Configure RB02C report parameters:
MinTime = 1min、MaxTime = 1min、BatteryChange = 0.1v
Downlink: 01A7003C003C0100000000
Device Return:
81A7000000000000000000 (Configuration success)
81A7010000000000000000 (Configuration failure)
(2)Read Device Configuration:
Downlink: 02A7000000000000000000

7
Device Return:
82A7003C003C0100000000 (Current configuration)
Example ofButton Pressing
FPort : 0x0D
Description
CmdID
PayLoad(Var bytes)
SetButtonPress
TimeReq
0x01
PressTime(1byte)
0x00_QuickPush_Less then 1 Second,
Other value present the presstime such as
0x01_1 Second push,
0x02_2 Seconds push,
0x03_3 Seconds push,
0x04_4 Seconds push,
0x05_5 Seconds push, and so on
SetButtonPress
TimeRsp
0x81
Status
(0x00_Success 0x01_Failure)
GetButtonPress
TimeReq
0x02
GetButtonPress
TimeRsp
0x82
PressTime(1byte)
Other value present the presstime such as
0x01_1 Second push,
0x02_2 Seconds push,
0x03_3 Seconds push,
0x04_4 Seconds push,
0x05_5 Seconds push, and so on
Other value is reserved
(1)Configure RB02C device parameter ButtonPressTime=0x0A ( Press and hold the button for 10 seconds to report )
Downlink: 010A
Device Return:
8100 (Configuration success)
8101(Configuration failure)
(2)Read RB02C device parameter:
Downlink: 02

8
Device Return:
820A (device current parameter)
*ButtonPressTime can be set to 255 at most.
Example for MinTime/MaxTime logic:
Example#1 based on MinTime = 1 Hour, MaxTime= 1 Hour, Reportable Change i.e. BatteryVoltageChange=0.1V
MaxTime MaxTime
Sleeping(MinTime) Sleeping(MinTime)
Note: MaxTime=MinTime. Data will only be report according to MaxTime (MinTime) duration regardless BatteryVoltageChange value.
Example#2 based on MinTime = 15 Minutes, MaxTime= 1 Hour, Reportable Change i.e. BatteryVoltageChange= 0.1V.
MaxTime
Sleeping(MinTime) sleeping sleeping sleeping
0H 15th M 30th M 45th M 1H 2H
Example#3 based on MinTime = 15 Minutes, MaxTime= 1 Hour, Reportable Change i.e. BatteryVoltageChange= 0.1V.
MaxTime
sleeping sleeping ...
0H 15th M 30th M 45th M 1H 1H 10th M 1H 25th M 1H 40th M 1H 55th M 2H 10th M
Notes :
1) The device only wakes up and performs data sampling according to MinTime Interval. When it is sleeping, it does not collect
data.
2) The data collected is compared with the last data reported. If the data variation is greater than the ReportableChange value, the
device reports according to MinTime interval. If the data variation is not greater than the last data reported, the device reports
according to MaxTime interval.
Wakes up and
collects data
3V
Does not report
Wakes up and
collects data
3V
Does not report
Wakes up and
collects data
3V
Does not report
Wakes up and
collects data
REPORTS 3V
Wakes up and
collects data
REPORT 3V
Wakes up and
collects data
REPORTS 3V
Wakes up and collects data
|2.9-3.0|=0.1
REPORTS 2.9V
Wakes up and
collects data
2.9V
Does not report
Wakes up and
collects data
2.9V
Does not report
Wakes up and
collects data
2.9V
Does not report
Wakes up and
collects data 2.9V
Does not report
Wakes up and
collects data
2.9V
Does not report
Wakes up and
collects data
REPORTS 2.9V
Wake up and collects data
REPORTS 3V
Wakes up and collects data
REPORTS 3V
Wakes up and collects data
REPORTS 3V
Wakes up and
collects data
3V
Does not report
Users push the button,
REPORTS 2.9V.
Recalculate MaxTime.

9
3) We do not recommend to set the MinTime Interval value too low. If the MinTime Interval is too low, the device wakes up
frequently and the battery will be drained soon.
4) Whenever the device sends a report, no matter resulting from data variation, button pushed or MaxTime interval, another cycle of
MinTime/MaxTime calculation is started.
6.Installation
1. Use the attached 3M rubber pad, stick one side to the
Wireless 3-Gang Push Button (RB02C), and stick the
other side to the wall.
2. To make the installation firmer, please use screws
(purchased separately) to fix the device to the wall.
* Note:
⚫Please don't stick it on the rough wall to avoid the device
from falling off after the long-term usage.
⚫If use the supplied 3M rubber pad, please wipe the wall
clean before installation to avoid dust on the wall and affect
the effect of the paste.
⚫The middle part of the 3M rubber pad (the part with the
red frame in the left picture below) is where the label is
attached to the device. Please remove the rubber pad that
has been cut.
⚫Do not install the device in a metal shielded box or in an
environment surrounded by other electrical equipment to
avoid affecting the wireless transmission of the device.
3.Install the battery in the battery slot, and close the snap-fit
joint of the device, as shown in the figure below.
*Note:
If user wants to open the snap-fit joint, user can pry it
gently.
RB02C can be applied to the following scenarios:
⚫Home (bathroom)
⚫School
⚫Nursing home
⚫Hospital
⚫Bank
⚫Hotel
The place where an emergency may occur.
3. When the button of the device is pressed, the device will send
button status.
When the device periodically reports data next time, it restores the
"normal" state and sends the "normal" state information.
When button pressing, the bit of data is "1".
When button no pressing, the bit of data is "0".
3M Rubber Pad
Screw holes
Snap-fit Joint

10
7. Important Maintenance Instruction
Kindly pay attention to the following in order to achieve the best maintenance of the product:
•Keep the equipment dry. Rain, moisture and various liquids or water may contain minerals that can corrode electronic circuits. In case
the device is wet, please dry it completely.
•Do not use or store in dusty or dirty areas. This way can damage its detachable parts and electronic components.
•Do not store in excessive heat place. High temperatures can shorten the life of electronic devices, destroy batteries, and deform or melt
some plastic parts.
•Do not store in excessive cold place. Otherwise, when the temperature rises to normal temperature, moisture will form inside which
will destroy the board.
•Do not throw, knock or shake the device. Treating equipment roughly can destroy internal circuit boards and delicate structures.
•Do not wash with strong chemicals, detergents or strong detergents.
•Do not paint the device. Smudges can make debris block detachable parts up and affect normal operation.
•Do not throw the battery into the fire to prevent the battery from exploding. Damaged batteries may also explode.
All the above suggestions apply equally to your device, batteries and accessories.