Nexo Geo M6 Series User manual

DP4306-01-DI
GEO M6
GEOM620 GEOM6B
User manual

TABLE OF CONTENTS
Page 2 / 20 GEOM6B-GEOM620
TABLE OF CONTENTS
TABLE OF CONTENTS___________________________________________________________________ 2
WARNINGS ____________________________________________________________________________ 3
DESCRIPTION__________________________________________________________________________ 4
PRESET GEOM6________________________________________________________________________ 5
GEOM6 RIGGING _______________________________________________________________________ 9
GEOM6 ACCESSORIES _______________________________________________________________ 10
ARRAY EQ____________________________________________________________________________ 14
MAINTENANCE________________________________________________________________________ 15
TECHNICAL SPECIFICATIONS ___________________________________________________________ 17
USER NOTES _________________________________________________________________________ 19
EU Conformity declaration
We,
NEXO SA
ZA DU PRE DE LA DAME JEANNE
60128 PLAILLY –France
Declare under our sole responsibility that the product
Type
Serial number
Loudspeaker
GEOM6
On the product
Is in conformity with the provisions of the following directive
including all applicable amendments:
2014/35/UE (Low Voltage Directive)
Applied rules and standards:
Plailly, June, 2014
EN 13155, EN 62368
Joseph CARCOPINO, R&D Director

WARNINGS
GEOM6B-GEOM620 Page 3 / 20
WARNINGS
PRECAUTIONS
-
repairable part.
If the system seems to be malfunctioning or damaged, stop using it at once and have it repaired by a NEXO qualified technician.
Do not expose the system directly to the sun or to the rain, do not immerse it into fluids, do not place objects filled with liquid on the
system. If a liquid gets into the system, please have it inspected by a NEXO qualified technician.
The connection should be performed by qualified technician, by ensuring that power is off.
Operating temperature with temperate climate: 0°C to +40°C (+32°F to +104); -20°C à +60°C (-4°F to +140°F) for storage.
SAFETY INFORMATIONS
Read this manual before using the speaker.
Keep this manual available for further reference.
Observe all warnings and cautions.
Please check the NEXO Web site nexo-sa.com to get the most up-to-date version of this manual.
Ensure you are aware of the safety rules applying to rigging, stacking or installing on tripod or speaker stand. Failure to observe
these rules may expose persons to potential wounds or even death.
Only use the system with accessories specified by NEXO.
Please always consult a NEXO-accredited technician if the installation needs architectural works and observe following precautions:
Mounting Precautions:
- Please select screws and mounting location supporting 4 times the system weight.
- Do not expose the system to excessive dust, vibrations, to extreme cold or hot temperatures, to reduce the risk of
damaging components.
- Do not place the system in an unstable position: it could fall accidentally.
- cations are adapted and that its height does not exceed
.
Connection and Powering Precautions:
- Unplug connected cables before moving the system.
- Power off the system before connecting the system.
- When switching on the installation, the amplifier must be powered last; when switching the installation off, shut off the
amplifier first.
- If you work by cold temperatures, progressively raise the level to nominal value during the first minutes of use, to allow the
system components to stabilize.
Please check regularly the system condition.
HIGH SOUND PRESSURE LEVELS
Exposure to very high sound pressure levels may cause permanent hearing losses. Degrees of hearing losses may be different
from one person to another, but almost everybody will be affected if exposed to high sound pressure levels during a long period of
time. The OSHA (Occupational Safety and Health Administration) American Agency specified the following maximal exposures:
Number of Hours
Sound Pressure Level (dBA),
Slow Response
8
90
6
92
4
95
3
97
2
100
1 ½
102
1
105
½
110
¼ or less
115
WASTE OF ELECTRIC OR ELECTRONIC EQUIPMENT
This symbol on the product or its packaging indicates that this product must not be treated as household waste.
Instead, it is your responsibility to hand it over to a designated collection point for the recycling of waste
electrical and electronic equipment. By ensuring your waste equipment is recycled, you will help prevent
potential negative consequences for the environment and human health, which could appear if this product was
not recycled. Recycling helps spare natural resources. For more information about the recycling of this product,
please contact your local city office, your household waste disposal service or your reseller.

DESCRIPTION
Page 4 / 20 GEOM6B-GEOM620
DESCRIPTION
→GEOM620 and GEOM6B are a mid-size line array. GEOM620 is a 2 ways passive, with a 6.5
With GEOM620, you can change the HF horizontal directivity from 80° to 120° by adding a pair of flanges.
→The GEOM6 can be stacked of flown with the HF waveguide exit on the left or the right side of the front panel, allowing to
broaden or narrow the stereo image depending on your need and the characteristics of the venue. We recommend to build
system with the HF waveguide on the outside of each assembly (larger stereo image).
→Versions:
•GEOM620: Touring or fix application; Black
•GEOM620-PW: Touring or fix application; White
•GEOM6B: Touring or fix application; Black
•GEOM6-PW: Touring or fix application; White
→Connectors:
•GEOM620/6B: two NL4 connectors, the 4 pins of the 2 sockets are connected in parallel within the enclosure.
- GEOM620: 2+/2-.
- GEOM6B: 1+/1-
→Amplification:
•The GEOM6 cabinets MUST be used with a NEXO processor to handle EQ, phase alignment, crossover and
excursion/thermal protection for the system loudspeakers.
•The following table shows the number of GEOM6 speakers and MSUB12 subwoofers usable with each solution.
DTD + DTDAMP4x0.7
DTD + DTDAMP4x1.3
NXAMP4x1MK2
NXAMP4x2MK2
NXAMP4x4MK2
GEOM620
Up to 2 per channel
Up to 2 per channel
Up to 3 per channel
Up to 4 per channel
Up to 4 per channel
GEOM6B
Up to 2 per channel
Up to 2 per channel
Up to 3 per channel
Up to 4 per channel
Up to 4 per channel
MSUB12
1 per channel
1 per channel
Up to 2 per channel
Up to 3 per channel
Up to 3 per channel
Recommended

PRESET GEOM6
GEOM6B-GEOM620 Page 5 / 20
PRESET GEOM6
Please consult nexo-sa.com for NEXO TD Controllers firmware information.
For the GEOM620 or GEOM6B, with or without directivity flanges, the following setups are available:
Passive Mode
•Setup for one stand-alone box, with high-pass at 50, 60, 75, 85, 95 or 120 Hz.
•Setup for arrays from 2 to 3 boxes, with high-pass at 50, 60, 75, 85, 95 or 120 Hz.
•Setup for arrays from 4 to 6 boxes, with high-pass at 50, 60, 75, 85, 95 or 120 Hz.
•Setup for arrays from 7 to 12 boxes, with high-pass at 50, 60, 75, 85, 95 or 120Hz.
•Setup for Stack Monitor, with high-pass at 50, 60 or 75 Hz.
1Box
Default Cross over on one box 50 Hz Front Fill, multi-diff, sound reinforcement all short throw application;
High SPL Small system using 2x GEOM6 and 2x MSUB12 in 85 Hz;

PRESET GEOM6
Page 6 / 20 GEOM6B-GEOM620
2-3Boxes
For small flying or stacking configuration, mid throw application used at 60 Hz without MSUB12 and 85 Hz
with set up 50-85 Hz for MSUB12.
For stack configuration using MSUB12 in OMNI or CARDIO mode with 1 Back and 2 Front and GEOM6
on top of them, MSUB12 should use the 50-85 Hz setup (85 Hz crossover should be used for GEOM6 as
well). A small overlap could have impact if needed, for example use MSUB12 with 50-120 Hz setup.

PRESET GEOM6
GEOM6B-GEOM620 Page 7 / 20
4-6Boxes
For long throw flying application used in GEOM6 at 60 Hz without Sub. MSUB12 should use the 50-120
Hz setup (120 Hz crossover should be used for GEOM6 as well). If a larger stacked Sub is used all
together, MSUB12 should use the 63-120 Hz setup.

PRESET GEOM6
Page 8 / 20 GEOM6B-GEOM620
7-12Boxes
For very long throw application, MSUB12 should be deployed using the 50-120 Hz setup (120 Hz
crossover should be used for GEOM6).
Ground Stack Sub design

GEOM6 RIGGING
GEOM6B-GEOM620 Page 9 / 20
GEOM6 RIGGING
Assembly
Front
Insert quick release pins 5x15mm (VXT-BL515) on both sides (or use GMI-BNFIX).
Back
Adjust the angle with the lift bar and lock with the quick release pin VXT-BL515 (or fasteners provided with GMI-BNFIX).

GEOM6 –ACCESSORIES
Page 10 / 20 GEOM6B-GEOM620
GEOM6 – ACCESSORIES
WARNINGS
All GEOM6 accessories are specifically rated in agreement with structural computations.
Never use other accessories –including push-pins –when assembling GEOM6 cabinets than the ones provided by NEXO:
NEXO will decline responsibility over the entire GEOM6 accessory range if any component is purchased from different
supplier.
All GEOM6 accessories have been designed so that cabinet are arrayed vertically.
GEOM6 horizontal assemblies as shown in figure below are UNSAFE and STRICTLY PROHIBITED
VNT-BUMPM6
Rated for a maximum of 12 GEOM6 or 8 MSUB12, or a
combination with a maximum of 4 MSUB12 and 6 GEOM6.
Flown on 1 or 2 rigging points.
Usable with VNT-EXBARM6 for extra tilt angle and flown on one
or two rigging points.
1 location for laser/clinometer.
Use VXT-BL615 or VNI-FIXBUMPM6 with MSUB12.
Use VXT-BL515 or GMI-BNFIX with GEOM6.
VNT-EXBARM6

GEOM6 –ACCESSORIES
GEOM6B-GEOM620 Page 11 / 20
VNT-MNSTKM6
Stacking option for GEOM6 on top of MSUB12
(with GMT-BUMPER).
GMT-BUMPER
Rated for a maximum of 12 GEOM6.
Usable with GMT-EXBAR for a one rigging point.
Stacking alone, rated for a maximum of 3x GEOM6.
GMT-LBUMP
Rated for a maximum of 3 GEOM6.
GMT-EXBAR

GEOM6 –ACCESSORIES
Page 12 / 20 GEOM6B-GEOM620
GMT-LBPADPT
Use with GMT-LBUMP
GMT-BPADPT-2
Use with GMT-BUMP for stacking.
GMT-FLG
Pair of flanges for 120°horizontal directivity.
VXT-BL515
Quick release pin 5x15mm for touring application.
GMI-BNFIX
Rigging fix.
GMI-IPCOV
IP54 connector box
VNI-WS15
Wall bracket, use with GMT-LBUMP (3 GEOM6 max)

GEOM6 –ACCESSORIES
GEOM6B-GEOM620 Page 13 / 20
VNI-LNKM61018
Adapter MSUB18-I to GEOM6 (with GMI-BNFIX).
(max 6x GEOM6)
VNT-TCBRK
Truss clamp adapter
VNT-XHBRK
Lifting ring
VNT-POLE
Pole mount adapter
GMT-6CASE: use for 6x GEOM6 and accessories

ARRAY EQ
Page 14 / 20 GEOM6B-GEOM620
ARRAY EQ
The ArrayEQ allows to adjust the system frequency response in its lower range
(see curves below, with different ArrayEq values):

MAINTENANCE
GEOM6B-GEOM620 Page 15 / 20
MAINTENANCE
Front panel disassembly
1
Remove the grid (2 screws Tx25).
2
Remove external 120° flange (2 screws Tx20).
3
Remove the front cabinet (6 screws Tx25).
4
Remove 4 screws Tx25 to access to the speaker.
Tightening torque: 3,5 Nm
5
Remove 3 nuts (Hex10) to access to the speaker.
6
Remove 4 screws (Allen 3), remove the cover and
accessto the diaphragm.

MAINTENANCE
Page 16 / 20 GEOM6B-GEOM620
Spare parts
MARK
QUANTITY
REFERENCE
DESIGNATION
1
1
05GEO-6UA
Complete grille black with logo and screws
1
05GEO-6UAPW
Complete grille white with logo and screws
2
1
05HPADE14-16
HF driver complete (with screws)
1
05NH14-16R/k
HF diaphragm HPADE14-16
3
1
HPB6-F
1
05HPB6-FR/K
Recone kit HPB6-F
4
1
05LEXWARM6
Lexan warning
5
1
05GEOM6LKB
LinkBar
6
2
05LEXRIGM6AG
Lexan angle
7
1
05GEOM620-FPA
Connecting plate
8
1
05LEXCNX620
Lexan GEOM620
1
05LEXCNX6B
Lexan GEOM6B
9
1
04VXT-BL515
Quick release pin 5x15
NOTE:
Speakers and Grills can be sent back to NEXO for recycling

TECHNICAL SPECIFICATIONS
GEOM6B-GEOM620 Page 17 / 20
TECHNICAL SPECIFICATIONS
GEOM620 WITH NEXO ELECTRONICS
Model
GEOM620
Frequency range (±6dB)
75Hz 20kHz
Sensibility (1W / 1m)
95dB SPL Nominal
Peak SPL Level (1m)
128dB
Operating voltage
30 Vrms
Vertical Dispersion
20°
Horizontal Dispersion
80° or 120° (with flanges GMT-FLG)
Crossover Frequency
LF-HF: 2kHz Passive
Nominal Impedance
Recommended Amplification
450 W per cabinet
SPECIFICATIONS
Model
GEOM620
Components
LF: 1x 6.5- - Long excursion
HF: 1x1throat driver on a BEA/FEA optimized HRWTM
Material
Lightweight polyurethane composite
Finish
Black or white structural paint
Front finish
Steel front grille
Black or white paint
Black or white mesh
Fittings
2 Side handles
Connector
2x NL4 connectors, 4 poles connectors
Weight
9.7 kg 21.4 lb
Dimensions

TECHNICAL SPECIFICATIONS
Page 18 / 20 GEOM6B-GEOM620
GEOM6B WITH NEXO ELECTRONICS
Model
GEOM6B
Frequency range (±6dB)
70Hz 1kHz
Sensibility (1W / 1m)
94dB SPL Nominal
Peak SPL Level (1m)
125dB
Operating voltage
30 Vrms
Nominal Impedance
Recommended Amplification
450 W per cabinet
SPECIFICATIONS
Model
GEOM6B
Components
LF: 1x 6.5- - Long excursion
Material
Lightweight polyurethane composite
Finish
Black or white structural paint
Front finish
Steel front grille
Black or white paint
Black or white mesh
Fittings
2 Side handles
Connector
2x NL4 connectors, 4 poles connectors
Weight
7.6 kg 13.8 lb