EN
3– English
5.1 - Transmitter to the used for programming
procedures
•The programming procedures can be performed exclusively with a Nice
transmitter having at least the following keys s, n, t.
•Theprogrammingproceduresmustbeperformedexclusivelywithatransmitter
memorised in “Mode I” (paragraph 5.5 or 5.9.1).
•Ifthetransmitterusedforprogrammingcontrolsmultipleautomationunits,you
must select the “unit” corresponding to the automation you are programming
before sending a command during a procedure.
5.2 - Positions in which the awning stops
automatically
The electronic system that controls the awning movement at all times can automati-
cally stop the movement when the awning reaches a certain position programmed
by the installer. The programmable positions are (g. 6):
– position “0”=upperlimitswitch:totallywoundawning;
– position “1”=lowerlimitswitch:totallyunwoundawning;
– position “H”=intermediateposition:partiallyopenawning.
Whenthelimitswitchesarenotprogrammedyet,theawningcanbemovedonlyin
the“hold-to-run”mode,i.e.keepingthecontrolkeypressedforthedesiredduration
of the manoeuvre; the movement stops as soon as the user releases the key. How-
ever,afterprogrammingthelimitswitches,brieypressingtheappropriatekey will
start the awning and it will stop moving automatically as soon as the awning reaches
the required position.
To adjust the distances “0” and “1” various procedures are possible; to choose the
appropriateone,takeintoaccountthesupportingstructureofyourawning(seethe
summary in the table).
WARNING! – If you want to again adjust again the height of the limit switch-
es adjusted previously, consider the following:
– If you would like to adjust them with an alternative procedure different
from the one used previously, you must FIRST delete the heights by fol-
lowing procedure 5.13.
– If you wish to adjust them with the same procedure used previously, you
need not delete them.
6
The programming of the limit switches simultaneously combines the two directions
of rotation of the motor to the respective shutter raising key (s) and shutter lowering
key (t)ofthecontroldevice(initially,whenthelimitswitchesarenotprogrammed
yet,thecombinationisrandomanditcanhappenthatwhenpressingtheskey,the
shuttermovesdowninsteadofup,orviceversa).
5.3 - General warnings
•Thelimitswitchmustbeadjustedafter installing the motor in the awning and con-
necting it to the power supply.
•Incasesofinstallationswithseveralmotorsand/orreceivers,beforestartingto
program you must disconnect the electrical supply to the motors and receivers you
do not wish to program.
•Scrupulouslyrespectthetimelimitsindicatedintheprocedures:afterreleasinga
key,youhave60secondstopressthenextkeyindicatedintheprocedure;other-
wise,whenthetimeisup,themotorwillperformsixmovementstocommunicate
cancellation of the procedure in progress.
•Duringprogramming,themotorperformsacertainnumberofbriefmovements,
as a “response” to the command sent to the installer. It is important to count the
number of these movements without considering the direction in which they are
performed.
•Everytimethemotorispowered,2movementsareperformedifatleastonetrans-
mitter and the limit switch heights are not in the memory.
5.4 - Overview of the transmitters
5.4.1 - Compatible transmitters
ConsulttheNiceproductcatalogueorgotowww.niceforyou.comtondtheNice
devices compatible with the radio receiver built into the motor.
5.4.2 - Transmitter memorisation hierarchy
IngeneralatransmittercanbememorisedasaFIRSTtransmitteroraSECOND
transmitter(orthird,fourth,etc.).
PROGRAMMING AND ADJUSTMENTS
5
The electrical connections must be made only after installing the motor and compat-
ible accessories required.
The electrical cord of the motor is made up of the following internal cables (g. 3):
Cable colour connection
1Brown Power supply phase
2Blue Neutral
3Yellow-green Earth
4.1 - Connection of motor to electricity mains
Utilisecords1,2,3(g. 3) to connect the motor to the main and pay attention to the
warnings:
– improperconnectioncancausebreakdownsandhazardoussituations;
– scrupulously respect the connections indicated in this manual;
– in the power supply network of the motor you must install a disconnection device
having an opening distance of the contacts that allows complete disconnection
intheovervoltagecategoryIIIconditions,inconformitywiththeinstallationrules
(disconnection device not supplied with the product).
4.2 - Connection of accessories to motor
Accessories can be connected by a radio (portable transmitters and certain
climatic sensor models):memorisetheseaccessoriesinthemotorduringthepro-
gramming phases; refer to the procedures given in this manual and those given in
the manuals supplied with the devices.
ELECTRICAL CONNECTIONS AND
FIRST POWER UP
4
ac
3.1 - Preliminary checks before installation and
limitations on use
•Checktheconditionoftheproductrightafterunpackingit.
•Thisproductisavailableinseveralversions,eachwithaspecicmotortorque.
Eachversionisdesignedtodriveawningsofacertainsizeandweight.There-
fore,beforeinstallationmakesuretheproduct’smotortorque,rotationspeedand
operationtimearesuitableforautomatingyourawning(seethe“GuidetoSelec-
tion”sectionintheNiceProductCatalogue–www.niceforyou.com).Inparticular,
do not install the product if its motor torque is greater than that needed to
move your awning.
•Checkthediameterofthewindingroller.Thismustbechosenaccordingtothe
motortorque,asfollows:
– formotorsthataresize“M”(Ø=45mm)andhaveatorqueofupto35Nm
(included),theminimuminsidediameterofthewindingrollermustbe52mm;
– formotorsthataresize“M”(Ø=45mm)andhaveatorqueofupto35Nm
(included),theminimuminsidediameterofthewindingrollermustbe60mm.
•Beforeautomatinganawning,checkthatthereisenoughfreespaceinfrontofit
for it to be completely opened.
•Ifthemotoristobeinstalledoutdoors,adequateprotectionagainstatmospheric
agents must be guaranteed.
Additionallimitationsonusearecontainedinchapters1and2andinthe“Technical
characteristics” section.
3.2 - Assembly and installation of the tubular motor
Warning! – Before starting, carefully read the warnings under sections 1.1
and 3.1. Incorrect installation could cause severe physical injury.
Toassembleandinstallthemotor,refertog. 4.Moreover,consulttheNiceprod-
uct catalogue or go to www.niceforyou.com to choose the crown of the limit switch
(g. 4-a),thedragwheel(g. 4-b) and the motor fastening bracket (g. 4-f).
3.3 - Installation of accessories (optional)
Afterinstallingthemotor,installtheaccessories,ifrequired.PerInordertoidentify
thosethatarecompatibleandchoosethemodelsdesired,seetheNiceproduct
catalogue,alsoviewableatwww.niceforyou.com.Fig. 3 shows the type of acces-
sories that are compatible and their connection to the motor (all of these are options
and not included in the package).
INSTALLATION OF THE MOTOR AND
THE ACCESSORIES
3