Nice EPad User manual

Page 1
Features:
• Stainlesssteelandcastzincalloyconstructionforresistanceagainstweatheringandvandalism.
• Eachkeyisbacklit.
• Built-intamperswitchmonitoring.
• Dooropen/closedmonitoringinput.
• Independentalarmoutput.
• Freeexitpushbuttoninput.
• Anti-hacking,multipleincorrectcodeinputlock-outandalarm.
• Eachrelayoutputcanbeindependentlysetuptolatchorpulse.
• EachrelayoutputoffersbothN/OandN/Ccontacts.
• Relay2(Auxoutput)canbeassignedtoactivate;
• SimultaneouslywithRelay1(Lockoutput).Whereeachrelaywillrespond,asperitsindependentlatchorpulsesetting.
• Whenthedoormonitoringcircuitisactivated.
• Whenthetamperswitchisactivated.
• Whenthe*keyisactivated.(Doorbell)
• Whenmultipleincorrectcodeshavebeenenteredconsecutively.
• WhenAuxcodeisentered.
• EachrelayhasitsownLEDindicatorforrelaystatusindicationataglance.
• Relay1(Lockoutput)canbeactivatedtolatchontemporarilywhileinpulsemode,usingtheunique“Bypass”code.
Specications:
Operatingvoltage: 12-24vAC/DC
Maximimumstandbycurrent: 100mA
Maximumloadondrycontactrelayoutputs: 3A@24v(Non-inductiveloadsonly)
Maximumloadonalarmoutput: 500mA@DC12v
Minimumcodelength: 4digits
Maximumcodelength: 8digits
MaximumnumberofusercodesonRelay1(Lockoutput): 98
MaximumnumberofusercodesonRelay2(Auxoutput): 1
MaximumnumberofusercodesonBypassfunction: 1
Relay1(Lockoutput)Pulselength: 1>99seconds
Relay2(Auxoutput)Pulselength: 1>999seconds
Dimensions: 120(H)x78(W)x35(D)
Ingressprotection. IP65
Stand-alone Hardwired Access Control
Keypad
Ver:EPAD_201105_008B
Nice

Page 2
1 2 34 5 6
8
7
9
10
Component Identication:
System restore (Factory default):
1. Relay1(LockOutput)terminalconnections.
2. Operatingpowerinputterminalconnections.
3. Alarmoutputterminalconnection.
4. Free-exitpushbuttoninputterminalconnection.
5. Dooropen/closedmonitoringswitchinputterminalconnection.
6. Relay2(AuxOutput)terminalconnections.
7. SystemRestore(FactoryDefault)dipswitch.
8. BypassDoormonitoring,dipswitch.
9. BypassTamperswitchmonitoring,dipswitch.
10. Built-intamperswitch.
1. Removepower.
2. Switch“Systemrestore”switchon.
3. Re-applypower.
4. Waitforbuzzertotoneconitinuously.
5. Switch“Systemrestore”switchoff.
Allsettingsandfeaturesarenowreturnedtofactorystatus.Allusercodesandthemastercodehavebeenresettofactory
default.

Page 3
Wiring:
Relay 1
Lock Output
NC COM NO
Alarm output, Free exit
push button and Door
monitoring input
ALM FRX
PB
0v Door
Relay 2
Aux Output
NC
NC
COM NO
Operating
power
input
0v
+12-24v
0v +v
Use the INI4007
diode when
power is DC. Use the INI4007 diode,
as power can only be DC.
Mag-lock example
Strike-lock example
4007
4007
470X
Use the 47pf
capacitor when
power is AC.
LED Indications:
Power LED Green LED
Relay 1
(Lock output)
Amber LED
Relay 2
(Auxiliary output)
Red=Normaloperatingmode On=relayactive On=relayactive
Yellow=Programmingmodeactive Off=relayinactive Off=relayinactive
Flashing=Alarmactivatedsincelast
validuserentered/exited.
Enteranyvalidusercodetwicetoclear
alarmmemory.
Nice
Power LED Green LED Amber LED

Page 4
Setup a new master code: (Default = 1234)
Setting up users 1 to 19 codes for relay 1 (Lock output): (User 1 default = 3333)
Setup code to activate the relay 2 (Aux output): (Default = 9999)
Typein-CurrentMasterCode+CurrentMasterCode(chime tone)+*+00+New4to8digitMasterCode+#(chime tone)
I.e.Tochangethemastercodeto4321:
Typein-12341234*004321#
Typein-MasterCode+MasterCode(chime tone)+*+twodigitusernumber+NewUserCode(chime tone)
I.e.Tosetupasingleusercode(exampleuser01to8282):-12341234*018282#
I.e.Tosetupmultipleusercodes:-12341234*018282*022222*033333……..#
NB!WhenprogramminganewcodefortheAuxiliaryrelay,thenewcodereplacestheoldcode,withnoneedtoerase
theoldcode.
Typein-MasterCode+MasterCode(chime tone)+*+40+NewAuxiliaryCode(chime tone)+#
I.e.TosetupAuxrelaycodeto2222:-12341234*402222#
Master code:
• Themastercodeisonlyusedtoaccessprogrammingmode.(Defaultmastercode=1234)
• Themastercodecanbe4to8digitsinlength.
• Thenumberofdigitsusedforthemastercodewilldeterminethelengthofallusercodes(Lock,Auxandbypassusers)
i.e.thedefaultmastercodeis1234.Thereforeallusercodeswillbe4digitslongunlessthemastercodeischanged.
• Ifthemastercodelengthischangedafterusercodeshavealreadybeenprogrammed,thefollowingwill
occur.
• Mastercodeshortened–thelastdigitsoftheusercodewillbedroppedmakingtheusercodesthesamelengthas
themastercode.
I.e.theoldmastercodewas123456anduser01was987654.
Newmasteris1234.User01becomes9876.
• Mastercodelengthincreased–zeroswillbeaddedtotheendofallusercodessothattheusercodesareequalin
lengthtothemastercode.
I.e.oldmastercodewas1234anduser01was9876
Newmastercode=123456.User01becomes987600
• Keeparecordofallcodesandneverattempttoprogramaduplicateofanothercodealreadyinthekeypad.
I.e.user01codecannotbethesameasthemastercode.
Otherpointstonotebeforeprogramming:
• Youcannotenterprogrammingmodeifoneoftherelaysisactive.
• Youcannotenterprogrammingmodeifthetamperswitchisactive.Closeupthekeypadhousingfirstorbypassthe
tamperswitchmonitoringusingthedip-switch.
• Toexitprogramming,atanystage,pressthe#key.

Page 5
Enable the incorrect code attempt lock out (Anti-hacking) feature: (Default = Disabled)
Setup bypass code: (Default = None)
Enabale the Bypass code function: (Default = Disabled)
Deleting relay 1 (Lock output) user codes:
Setup type or pulse length of relay 1 (Lock output): (Default = 1 sec.)
Setup type or pulse length of relay 2 (Aux output): (Default = Latch mode)
Keypaddisableskeystrokesfor30sec.after5incorrectcodeentriesorif20consecutiveincorrectkeystrokeshavebeen
entered.NB!Typing#betweenkeystrokesrestartstheincorrectkeystrokecounter.
Typein-MasterCode+MasterCode(chime tone)+*+51(chime tone)+#
Repeatthistode-activateagain.
Typein-MasterCode+MasterCode(chime tone)+*+54+Newuniquebypasscode(chime tone)+#
NEVER USE WITH SOLENOID TYPE STRIKERS or LOCKS!
WhentheBypasscodeisentered,Relay1/Lockoutputlatchesonuntilthebypasscodeisre-enteredorwhentheFRX
push-buttonisused.
Enable the bypass code function:
Typein-MasterCode+MasterCode(chime tone)+*+52+1(chime tone)+#
Disable the bypass code function:
Typein-MasterCode+MasterCode(chime tone)+*+52+0(chime tone)+#
Deleting an individual user code;
Typein-MasterCode+MasterCode(chime tone)+*+50+twodigitusernumber(chime tone)+#
Deleting all user codes; (User01defaultsto3333)
Typein-MasterCode+MasterCode(chime tone)+*+50+00(chime tone)+#
Set for Latch mode;
Typein-MasterCode+MasterCode(chime tone)+*+20+00(chime tone)+#
Set for pulse mode and set pulse length;
Typein-MasterCode+MasterCode(chime tone)+*+20+01for1sec…….99for99sec(chime tone)+#
Set for Latch mode;
Typein-MasterCode+MasterCode(chime tone)+*+58+000(chime tone)+#
Set for pulse mode and set pulse length;
Typein-MasterCode+MasterCode(chime tone)+*+58+001for1sec…….999for999sec(chime tone)+#

Page 6
Advanced Programming Options and Quick Reference Table
Need Action Factory
Default
Enterprogramming Mastercode+Mastercode 1234
Master and user codes
ChangeMastercode *00+Newmastercode
Setusercodes01-19
(Relay1/Lockoutputonly)
*2digitusercode+Newuniqueusercode.
Code must be the same length as the master code. 01=3333
Setusercodes20-39and41
-98
(Relay1/Lockoutputonly)
*6+2digitusercode+Newuniqueusercode.
Code must be the same length as the master code. None
Setusercode40
(Relay2/Auxoutputonly)
*40+Newuniqueusercode.
Code must be the same length as the master code. 9999
Deleteusercodes *50+00(Forallusercodes)
*50+2digitusernumber(Forindependentusers)
01=3333ifall
deleted
Relays
setup
Setuplatchorpulselength.
(Relay1/Lockoutput)
*20+00=Latchmode
or01=1sec,02=2sec....99=99sec. 1Second
Setuplatchorpulselength.
(Relay2/Auxoutput)
*58+000=Latchmode
or001=1sec,002=2sec....999=999sec. Latchmode
Bypass
setup
Enablebypassmode *52+1 Disabled
Disablebypassmode *52+0 Default
Setbypasscode *52+Newuniquebypasscode None
Alarms and Security
Enablemultipleincorrectcode
lock-out.
(Anti-hackingfeature)
*51totogglebetweenenabledordisabled Disabled
DisableAlarmoutputmode *55+0 Disabled
Doormonitoring-forcedopenor
jammedopenalarm *55+1(Dooropentime=Relay1/Lockoutputpulselength Disabled
Tamperalarm *55+2 Disabled
Tamperanddoormonitoralarm *55+3 Disabled
Alarmactivetime *56+001for1sec,002for2sec.........999for999sec Disabled
Auxiliary Output
(Relay 2)
DisableAuxoutput *57+0 Enabled
Auxoutputtoactivatewhendoor
monitorinputistriggered(FRXfor
Auxoutput)
*57+1 Disabled
Auxoutputtoactivatewhen
anti-hackingistriggered
*57+2(NotfunctionalifRelay2/Auxoutputissettolatch
mode) Disabled
Auxoutputtoactivatewhen*key
ispressed.(Doorbellfunction) *57+3 Disabled
Auxoutputtoactivatewhentam-
peristriggered *57+4 Disabled
Auxoutputtoactivatewhendoor
isforcedorjammedopen *57+5 Disabled
AuxoutputtoactivatewhenRe-
lay1/Lockoutputisactivated *57+6 Disabled
Auxoutputtoactivatewhenuser
40codeisentered *57+7 Enabled

Page 7
Using the Keypad
Normal operation:
Alarm Monitoring Function:
Bypass Function:
ToactivateRelay1/Lockoutput,simplytypeinavalidcodeforthatrelayorpressandreleasethefreeexitpushbuttonifone
hasbeeninstalled:
-Therelaywillactivateinthemannersetupbytheinstaller.
-ThegreenLEDindicatorwillactivateaspertherelay.
ToactivateRelay2/Auxoutput,simplytypeinthevalidcodeforthatrelayorpressandreleasethefreeexitpushbuttonifthis
functionhasbeenconfiguredandinstalled:
-Therelaywillactivateinthemannersetupbytheinstaller.
-TheyellowLEDwillactivateaspertherelay.
Ifthealarmmonitoringhasbeensetupbytheinstaller,andanalarmconditionoccurs,thefollowingwillhappen;
• Alarmoutputactivates,
• Builtinbuzzersounds,
• GreenLEDbeginsflashing.
Thefollowalarmconditionsareavailable:
• Dooropenedwithoutavalidcodeentryfirst.(Doorforcedalarm)
• DoornotclosedbythetimetheRelay1/Lockoutputreturnstostandbystatus.(Doorjammedopenalarm)
• Keypadhousingopened.(Tamperalarm)
Afterthealarmtime(setbytheinstaller)hasexpired,thealarmoutputandthebuiltinbuzzerresets.However,the
flashinggreenLEDcontinuesuntilthefirstvalidusercodeisenteredintothekeypad.Thiswaytheuserismadeaware
thatanalarmconditionoccurredevenafterthebuiltinbuzzerandalarmoutputhavereset.
TO AVOID OVERHEATING OF THE SOLENOID, NEVER USE THIS FUNCTION WITH ELECTRO-MECHANICAL
STRIKERS or LOCKS!
Incasessuchasanofficeparkorschoolgateautomation,thatneedstotemporarilybekeptopentoallowforpeaktraffic
periods,thisfunctioncanbeused.
Thisfunctionrequiresadedicatedcodewhichissetupbythemastercodeholder.
Whenthebypasscodeisentered,Relay1/Lockoutputwilllatchonuntileitherthesamecodeisenteredagainorthefree
exitpushbuttonispressed.
Whilethebypassfunctionisactive,nootherRelay1/Lockoutputusercodewillreleasetherelay.
Thisfunctionisalsousefulwhereamagneticlockisinstalled.

Page 8
Tel: +27 21 404 0800 Tech support email: supportza@niceforyou.com Webpage: www.niceforyou.com/za
WARRANTY:
1. AllgoodsmanufacturedbyNiceGroupSA(Pty)Ltdcarrya12monthfactorywarrantyfromdateofinvoice.
2. Allgoodsarewarrantedtobefreeoffaultycomponentsandmanufacturingdefects.
3. Faultygoodswillberepairedorreplaced,atthesolediscretionofNiceGroupSA(Pty)Ltd,freeofcharge.
4. ThiswarrantyissubjecttothegoodsbeingreturnedtothepremisesofNiceGroupSA(Pty)Ltd.
5. Thecarriageofgoodsisforthecustomer’saccount.
6. Thiswarrantyisonlyvalidifthecorrectinstallationandapplicationofgoods,aslaidoutintheapplicabledocumentation
accompanyingsaidgoods,isadheredto.
7. Allwarrantyclaimsmustbeaccompaniedbytheoriginalinvoice.
8. Allclaimsmadebytheendusermustbedirectedtotheirrespectiveserviceprovider/installer.
Thefollowingconditionswilldisqualifythisproductfromthewarrantyaslaidoutabove.Theseconditionsarenon-negotiable.
1. Anyunauthorizednon-manufacturermodificationstotheproductorcomponentsthereof.
2. Anymodificationtotheinstallationmethodsdescribedintheinstallationinstructions.
3. Any application or use of the product other than the intended use and application prescribed in the product
documentation.
Thefollowingitemsarenotincludedinthewarrantyortheycarryaspecialwarrantyconditionoftheirown.
1. Damageresultantofwindandotherclimaticinfluencessuchaslightningstrikes.
2. Damageduetohighvoltagesurges.
3. Damageduetoinfestationi.e.Antsnesting…
4. Waterdamage.Itistheresponsibilityoftheinstallertoensuretheproductisinstalledinalocationthatisprotected
fromwateringress.Theingressprotectionratingisspecifiedintheaccompanyingdocumentation.Housingsthat
requirethatcableentriesbe madebythe installerdonot carryanex-factory ingressprotectionrating asitis the
responsibilityoftheinstallertosealthecableentrypointsafterinstallationofthecabling.