Features:
• Stainlesssteelandcastzincalloyconstructionforresistanceagainstweatheringandvandalism.
• Eachkeyisbacklit.
• Built-intamperswitchmonitoring.
• Dooropen/closedmonitoringinput.
• Independentalarmoutput.
• Freeexitpushbuttoninput.
• Anti-hacking,multipleincorrectcodeinputlock-outandalarm.
• Eachrelayoutputcanbeindependentlysetuptolatchorpulse.
• EachrelayoutputoffersbothN/OandN/Ccontacts.
• Relay2(Auxoutput)canbeassignedtoactivate;
• SimultaneouslywithRelay1(Lockoutput).Whereeachrelaywillrespond,asperitsindependentlatchorpulsesetting.
• Whenthedoormonitoringcircuitisactivated.
• Whenthetamperswitchisactivated.
• Whenthe*keyisactivated.(Doorbell)
• Whenmultipleincorrectcodeshavebeenenteredconsecutively.
• WhenAuxcodeisentered.
• EachrelayhasitsownLEDindicatorforrelaystatusindicationataglance.
• Relay1(Lockoutput)canbeactivatedtolatchontemporarilywhileinpulsemode,usingtheunique“Bypass”code.
Specications:
Operatingvoltage: 12-24vAC/DC
Maximimumstandbycurrent: 100mA
Maximumloadondrycontactrelayoutputs: 3A@24v(Non-inductiveloadsonly)
Maximumloadonalarmoutput: 500mA@DC12v
Minimumcodelength: 4digits
Maximumcodelength: 8digits
MaximumnumberofusercodesonRelay1(Lockoutput): 98
MaximumnumberofusercodesonRelay2(Auxoutput): 1
MaximumnumberofusercodesonBypassfunction: 1
Relay1(Lockoutput)Pulselength: 1>99seconds
Relay2(Auxoutput)Pulselength: 1>999seconds
Dimensions: 120(H)x78(W)x35(D)
Ingressprotection. IP65
Stand-alone Hardwired Access Control
Keypad
Ver:EPAD_201105_008B
Nice

Page 2
1 2 34 5 6
8
7
9
10
Component Identication:
System restore (Factory default):
1. Relay1(LockOutput)terminalconnections.
2. Operatingpowerinputterminalconnections.
3. Alarmoutputterminalconnection.
4. Free-exitpushbuttoninputterminalconnection.
5. Dooropen/closedmonitoringswitchinputterminalconnection.
6. Relay2(AuxOutput)terminalconnections.
7. SystemRestore(FactoryDefault)dipswitch.
8. BypassDoormonitoring,dipswitch.
9. BypassTamperswitchmonitoring,dipswitch.
10. Built-intamperswitch.
1. Removepower.
2. Switch“Systemrestore”switchon.
3. Re-applypower.
4. Waitforbuzzertotoneconitinuously.
5. Switch“Systemrestore”switchoff.
Allsettingsandfeaturesarenowreturnedtofactorystatus.Allusercodesandthemastercodehavebeenresettofactory
default.

Page 3
Wiring:
Relay 1
Lock Output
NC COM NO
Alarm output, Free exit
push button and Door
monitoring input
ALM FRX
PB
0v Door
Relay 2
Aux Output
NC
NC
COM NO
Operating
power
input
0v
+12-24v
0v +v
Use the INI4007
diode when
power is DC. Use the INI4007 diode,
as power can only be DC.
Mag-lock example
Strike-lock example
4007
4007
470X
Use the 47pf
capacitor when
power is AC.
LED Indications:
Power LED Green LED
Relay 1
(Lock output)
Amber LED
Relay 2
(Auxiliary output)
Red=Normaloperatingmode On=relayactive On=relayactive
Yellow=Programmingmodeactive Off=relayinactive Off=relayinactive
Flashing=Alarmactivatedsincelast
validuserentered/exited.
Enteranyvalidusercodetwicetoclear
alarmmemory.
Nice
Power LED Green LED Amber LED

Page 4
Setup a new master code: (Default = 1234)
Setting up users 1 to 19 codes for relay 1 (Lock output): (User 1 default = 3333)
Setup code to activate the relay 2 (Aux output): (Default = 9999)
Typein-CurrentMasterCode+CurrentMasterCode(chime tone)+*+00+New4to8digitMasterCode+#(chime tone)
I.e.Tochangethemastercodeto4321:
Typein-12341234*004321#
Typein-MasterCode+MasterCode(chime tone)+*+twodigitusernumber+NewUserCode(chime tone)
I.e.Tosetupasingleusercode(exampleuser01to8282):-12341234*018282#
I.e.Tosetupmultipleusercodes:-12341234*018282*022222*033333……..#
NB!WhenprogramminganewcodefortheAuxiliaryrelay,thenewcodereplacestheoldcode,withnoneedtoerase
theoldcode.
Typein-MasterCode+MasterCode(chime tone)+*+40+NewAuxiliaryCode(chime tone)+#
I.e.TosetupAuxrelaycodeto2222:-12341234*402222#
Master code:
• Themastercodeisonlyusedtoaccessprogrammingmode.(Defaultmastercode=1234)
• Themastercodecanbe4to8digitsinlength.
• Thenumberofdigitsusedforthemastercodewilldeterminethelengthofallusercodes(Lock,Auxandbypassusers)
i.e.thedefaultmastercodeis1234.Thereforeallusercodeswillbe4digitslongunlessthemastercodeischanged.
• Ifthemastercodelengthischangedafterusercodeshavealreadybeenprogrammed,thefollowingwill
occur.
• Mastercodeshortened–thelastdigitsoftheusercodewillbedroppedmakingtheusercodesthesamelengthas
themastercode.
I.e.theoldmastercodewas123456anduser01was987654.
Newmasteris1234.User01becomes9876.
• Mastercodelengthincreased–zeroswillbeaddedtotheendofallusercodessothattheusercodesareequalin
lengthtothemastercode.
I.e.oldmastercodewas1234anduser01was9876
Newmastercode=123456.User01becomes987600
• Keeparecordofallcodesandneverattempttoprogramaduplicateofanothercodealreadyinthekeypad.
I.e.user01codecannotbethesameasthemastercode.
Otherpointstonotebeforeprogramming:
• Youcannotenterprogrammingmodeifoneoftherelaysisactive.
• Youcannotenterprogrammingmodeifthetamperswitchisactive.Closeupthekeypadhousingfirstorbypassthe
tamperswitchmonitoringusingthedip-switch.
• Toexitprogramming,atanystage,pressthe#key.

Page 5
Enable the incorrect code attempt lock out (Anti-hacking) feature: (Default = Disabled)
Setup bypass code: (Default = None)
Enabale the Bypass code function: (Default = Disabled)
Deleting relay 1 (Lock output) user codes:
Setup type or pulse length of relay 1 (Lock output): (Default = 1 sec.)
Setup type or pulse length of relay 2 (Aux output): (Default = Latch mode)
Keypaddisableskeystrokesfor30sec.after5incorrectcodeentriesorif20consecutiveincorrectkeystrokeshavebeen
entered.NB!Typing#betweenkeystrokesrestartstheincorrectkeystrokecounter.
Typein-MasterCode+MasterCode(chime tone)+*+51(chime tone)+#
Repeatthistode-activateagain.
Typein-MasterCode+MasterCode(chime tone)+*+54+Newuniquebypasscode(chime tone)+#
NEVER USE WITH SOLENOID TYPE STRIKERS or LOCKS!
WhentheBypasscodeisentered,Relay1/Lockoutputlatchesonuntilthebypasscodeisre-enteredorwhentheFRX
push-buttonisused.
Enable the bypass code function:
Typein-MasterCode+MasterCode(chime tone)+*+52+1(chime tone)+#
Disable the bypass code function:
Typein-MasterCode+MasterCode(chime tone)+*+52+0(chime tone)+#
Deleting an individual user code;
Typein-MasterCode+MasterCode(chime tone)+*+50+twodigitusernumber(chime tone)+#
Deleting all user codes; (User01defaultsto3333)
Typein-MasterCode+MasterCode(chime tone)+*+50+00(chime tone)+#
Set for Latch mode;
Typein-MasterCode+MasterCode(chime tone)+*+20+00(chime tone)+#
Set for pulse mode and set pulse length;
Typein-MasterCode+MasterCode(chime tone)+*+20+01for1sec…….99for99sec(chime tone)+#
Set for Latch mode;
Typein-MasterCode+MasterCode(chime tone)+*+58+000(chime tone)+#
Set for pulse mode and set pulse length;
Typein-MasterCode+MasterCode(chime tone)+*+58+001for1sec…….999for999sec(chime tone)+#

Page 6
Advanced Programming Options and Quick Reference Table
Need Action Factory
Default
Enterprogramming Mastercode+Mastercode 1234
Master and user codes
ChangeMastercode *00+Newmastercode
Setusercodes01-19
(Relay1/Lockoutputonly)
*2digitusercode+Newuniqueusercode.
Code must be the same length as the master code. 01=3333
Setusercodes20-39and41
-98
(Relay1/Lockoutputonly)
*6+2digitusercode+Newuniqueusercode.
Code must be the same length as the master code. None
Setusercode40
(Relay2/Auxoutputonly)
*40+Newuniqueusercode.
Code must be the same length as the master code. 9999
Deleteusercodes *50+00(Forallusercodes)
*50+2digitusernumber(Forindependentusers)
01=3333ifall
deleted
Relays
setup
Setuplatchorpulselength.
(Relay1/Lockoutput)
*20+00=Latchmode
or01=1sec,02=2sec....99=99sec. 1Second
Setuplatchorpulselength.
(Relay2/Auxoutput)
*58+000=Latchmode
or001=1sec,002=2sec....999=999sec. Latchmode
Bypass
setup
Enablebypassmode *52+1 Disabled
Disablebypassmode *52+0 Default
Setbypasscode *52+Newuniquebypasscode None
Alarms and Security
Enablemultipleincorrectcode
lock-out.
(Anti-hackingfeature)
*51totogglebetweenenabledordisabled Disabled
DisableAlarmoutputmode *55+0 Disabled
Doormonitoring-forcedopenor
jammedopenalarm *55+1(Dooropentime=Relay1/Lockoutputpulselength Disabled
Tamperalarm *55+2 Disabled
Tamperanddoormonitoralarm *55+3 Disabled
Alarmactivetime *56+001for1sec,002for2sec.........999for999sec Disabled
Auxiliary Output
(Relay 2)
DisableAuxoutput *57+0 Enabled
Auxoutputtoactivatewhendoor
monitorinputistriggered(FRXfor
Auxoutput)
*57+1 Disabled
Auxoutputtoactivatewhen
anti-hackingistriggered
*57+2(NotfunctionalifRelay2/Auxoutputissettolatch
mode) Disabled
Auxoutputtoactivatewhen*key
ispressed.(Doorbellfunction) *57+3 Disabled
Auxoutputtoactivatewhentam-
peristriggered *57+4 Disabled
Auxoutputtoactivatewhendoor
isforcedorjammedopen *57+5 Disabled
AuxoutputtoactivatewhenRe-
lay1/Lockoutputisactivated *57+6 Disabled
Auxoutputtoactivatewhenuser
40codeisentered *57+7 Enabled

Page 7
Using the Keypad
Normal operation:
Alarm Monitoring Function:
Bypass Function:
ToactivateRelay1/Lockoutput,simplytypeinavalidcodeforthatrelayorpressandreleasethefreeexitpushbuttonifone
hasbeeninstalled:
-Therelaywillactivateinthemannersetupbytheinstaller.
-ThegreenLEDindicatorwillactivateaspertherelay.
ToactivateRelay2/Auxoutput,simplytypeinthevalidcodeforthatrelayorpressandreleasethefreeexitpushbuttonifthis
functionhasbeenconfiguredandinstalled:
-Therelaywillactivateinthemannersetupbytheinstaller.
-TheyellowLEDwillactivateaspertherelay.
Ifthealarmmonitoringhasbeensetupbytheinstaller,andanalarmconditionoccurs,thefollowingwillhappen;
• Alarmoutputactivates,
• Builtinbuzzersounds,
• GreenLEDbeginsflashing.
Thefollowalarmconditionsareavailable:
• Dooropenedwithoutavalidcodeentryfirst.(Doorforcedalarm)
• DoornotclosedbythetimetheRelay1/Lockoutputreturnstostandbystatus.(Doorjammedopenalarm)
• Keypadhousingopened.(Tamperalarm)
Afterthealarmtime(setbytheinstaller)hasexpired,thealarmoutputandthebuiltinbuzzerresets.However,the
flashinggreenLEDcontinuesuntilthefirstvalidusercodeisenteredintothekeypad.Thiswaytheuserismadeaware
thatanalarmconditionoccurredevenafterthebuiltinbuzzerandalarmoutputhavereset.
TO AVOID OVERHEATING OF THE SOLENOID, NEVER USE THIS FUNCTION WITH ELECTRO-MECHANICAL
STRIKERS or LOCKS!
Incasessuchasanofficeparkorschoolgateautomation,thatneedstotemporarilybekeptopentoallowforpeaktraffic
periods,thisfunctioncanbeused.
Thisfunctionrequiresadedicatedcodewhichissetupbythemastercodeholder.
Whenthebypasscodeisentered,Relay1/Lockoutputwilllatchonuntileitherthesamecodeisenteredagainorthefree
exitpushbuttonispressed.
Whilethebypassfunctionisactive,nootherRelay1/Lockoutputusercodewillreleasetherelay.
Thisfunctionisalsousefulwhereamagneticlockisinstalled.

Page 8
Tel: +27 21 404 0800 Tech support email: supportza@niceforyou.com Webpage: www.niceforyou.com/za
WARRANTY:
1. AllgoodsmanufacturedbyNiceGroupSA(Pty)Ltdcarrya12monthfactorywarrantyfromdateofinvoice.
2. Allgoodsarewarrantedtobefreeoffaultycomponentsandmanufacturingdefects.
3. Faultygoodswillberepairedorreplaced,atthesolediscretionofNiceGroupSA(Pty)Ltd,freeofcharge.
4. ThiswarrantyissubjecttothegoodsbeingreturnedtothepremisesofNiceGroupSA(Pty)Ltd.
5. Thecarriageofgoodsisforthecustomer’saccount.
6. Thiswarrantyisonlyvalidifthecorrectinstallationandapplicationofgoods,aslaidoutintheapplicabledocumentation
accompanyingsaidgoods,isadheredto.
7. Allwarrantyclaimsmustbeaccompaniedbytheoriginalinvoice.
8. Allclaimsmadebytheendusermustbedirectedtotheirrespectiveserviceprovider/installer.
Thefollowingconditionswilldisqualifythisproductfromthewarrantyaslaidoutabove.Theseconditionsarenon-negotiable.
1. Anyunauthorizednon-manufacturermodificationstotheproductorcomponentsthereof.
2. Anymodificationtotheinstallationmethodsdescribedintheinstallationinstructions.
3. Any application or use of the product other than the intended use and application prescribed in the product
documentation.
Thefollowingitemsarenotincludedinthewarrantyortheycarryaspecialwarrantyconditionoftheirown.
1. Damageresultantofwindandotherclimaticinfluencessuchaslightningstrikes.
2. Damageduetohighvoltagesurges.
3. Damageduetoinfestationi.e.Antsnesting…
4. Waterdamage.Itistheresponsibilityoftheinstallertoensuretheproductisinstalledinalocationthatisprotected
fromwateringress.Theingressprotectionratingisspecifiedintheaccompanyingdocumentation.Housingsthat
requirethatcableentriesbe madebythe installerdonot carryanex-factory ingressprotectionrating asitis the
responsibilityoftheinstallertosealthecableentrypointsafterinstallationofthecabling.
Table of contents
Other Nice IP Access Controllers manuals
Popular IP Access Controllers manuals by other brands

Micro ID Sdn Bh
Micro ID Sdn Bh MZ11D7 quick start guide

Extel
Extel JAZZY 100 instructions

Kimaldi
Kimaldi Kreta3 Installation and programming manual

Accentronix
Accentronix Cellswitch INFINITY quick start guide

Häfele
Häfele WT 210 BLE operating instructions

SECO-LARM
SECO-LARM ENFORCER SK-B241-PQ Installation Manual and Administrator Guide