Access programming mode → Add/Delete → Add -> RF-Learn → Input 5/6-digit user address
→ Input Tag Units(pcs) → Close Tag into RF Area
※ If adding a batch of Sequential tags, please input Tag Units(pcs) in the quantity of the tags and present the
tag with the lowest card code to the access controller.
1 2
Adding Tag by RF Learn Function Tag Information
SITE CODE
CARD CODE
SITE CODE
CARD CODE
※ User capacity: 16384 (00000~16383)
Access programming mode → Add/Delete → Add -> Card ID → Input 5/6-digit user address → Input Site Code → Input Card Code
11
Adding Tag by Tag ID
Access programming mode → Add/Delete → Delete -> Addr → Input Starting address → Input Ending address
1 5
Deleting User Address
Access programming mode → User Setting → Access Mode → Input User Address → 0: Invalid; 1: Card ; 2: Card or PIN; 3: Card & PIN
2 2
Setting up the access mode
Access programming mode → Add/Delete → Delete -> ID # → Input Site Code → Input Card Code
1 6
Deleting Tag by Tag ID
F. PIN Code
C. Initial setup
E. Duress Code
Access programming mode → User Setting → Password → Input
5/6-digit user address → Input 4-digit PIN (0001~9999) → Succeeded Or via
701Client set it on Users screen
21
Node ID of Reader Setting
Access programming mode → Parameters[1] → Node
ID → Input New Node ID : 1~254 (default value:001) → Main
Door Number : 0~255 → WG1 Door Number : 0~255 →
Show WG Message (0=No,1=Enable) → Network setting
→ Succeeded
3 1
Language Setting
Access programming mode → Tools → Language →
0EN → Succeeded → Initial system...
5 1
H. Enable Voice Module (supporting version : F/w Ver 3.02
or later)
Software Setting 701 Server or
Programming
B. Entering and Exiting Programming Mode
Changing the Master Code
Access programming mode → Tools → Master Code →
Input the 6-digit new master code → Succeeded
5 2
A. Keyboard Lock/ Unlock
Lock/ Unlock
Press and , and at the same time to lock keyboard.
Press again to unlock.
Entering
Input 123456 or PPPPPP
[e.g.] The Default Value= 123456. If already changed the Master
Code= 876112, input 876112 → Access programming mode
P.S.If entering no instruction within 30 sec., it will automatically
leave the programming mode.
Exiting
Press the repeatedly → Quit or Quit and Arming
(Please refer to alarm / arming setting)
6 7
G. Setting up the alarm / arming
Conditions: 1. Arming enabled 2.Alarm system connected
Application:
1. Door open too long: Door is open longer than door relay time plus door close
time.
2. Force open (Opened without a valid user card): Access by force or illegal
procedure.
3. Door position abnormal: When power is o and then on, reader on arming
before power o.
Step 1. Click "Read from Controller"
Step 2. Select "Card Reader / Voice Module" in RS485-2 section.
Step 3. Click "Write to Controller" to nish the setting.
Hardware setting
Access programming mode → Tools → Ext. Comm Port → Voice
552
Adding and Deleting Tag
1
2
3
Or via 701Server to set it on AR-829E-V5 screen
※Duress Code is only available in networking mode. It will
substitute a personal pin code and send the message of Duress
to computer as a warning signal.
※The Duress Code 0000 means that disable Duress Function and
the default value is set as 0000 already.
Access programming mode → Parameters[2] → Duress
Code → 4 sets (select one) → Input 4-digit PIN (0001~9999) →
Succeeded
4 7
D. PIN & UID Length setting
Access programming mode → Parameters[1] → PIN & UID
format → User PIN Length Range:4~8(4 is default value)
;
Card PIN Length Range:2~8(4 is default value)