NODEXON NX-5610-48G User manual

NX-5610-48G
Core Aggregation Switch
Product Guide

1
Statement of Copyright
Nodexon Networks©2021
All copyrights in this document are reserved by Nodexon Networks. Without Nodexon Networks'
prior written approval, any reproduction, excerption, backup, modification, transmission,
translation, or commercial use of this document or any portion of this document, in any form or
by any means, is forbidden.
Statement of Exemption
This material is being distributed "as is." This document's contents are subject to change at any
time without notice. Please visit the Nodexon Networks website for the most up-to-date
information. Nodexon Networks makes every effort to guarantee content accuracy, but cannot be
held liable for any losses or damages incurred as a result of content omissions, inaccuracies, or
mistakes.
Obtaining Technical Assistance
Website:https://www.nodexon.com/
Technical Support Website:https://nodexon.com/support
Community:http://www.nodexon.com/community
Case Portal :https://www.nodexon.com/caseportal
Website:https://www.nodexon.com/

2
Preface
Thank you for using our products. This manual will guide you through the installation of the
device.
This manual describes the functional and physical features and provides the device installation
steps, hardware troubleshooting, module technical specifications, and specifications and usage
guidelines for cables and connectors.
Audience
It is intended for the users who have some experience in installing and maintaining network
hardware. At the same time, it is assumed that the users are already familiar with the related
terms and concepts.

3
Introduction To The Installation Manual
The Product User's Manual mainly introduces the software and hardware parameters, installation
methods, and precautions during the installation process of the NX-5610-48G switch.
This manual includes the following sections:
Chapter 1: Product introduction. Briefly describe the basic functions and features of the switch,
detailed hardware and software specifications, and appearance information.
Chapter 2: Hardware Connections. Guide the connection and precautions between the switch and
other devices.
Chapter 3: Product Installation. Guide the hardware installation method and precautions of the
switch.
Chapter 4: Product Packaging and Use Recommendations

4
Chapter 1 Product Introduction
1.1 Product Introduction
The NX-5610-48G adopts a new generation of high-performance hardware and software
platform to provide flexible and cost-effective full Gigabit access and uplink ports. It supports
Layer 3 routing protocols, complete security protection mechanisms, and complete ACL/QoS
policies and enrichment. The VLAN function is easy to manage and maintain. It meets the
user's easy-to-manage, high-security, and low-cost networking requirements for network
devices. It is suitable for network access, aggregation, and core application scenarios in
campus, hotel, and enterprise campus.
1. 2 Product Features
•Full Gigabit Ethernet port: 48 full Gigabit RJ45 network ports, and 4 10 Gigabit SFP fiber ports,
breaking the traditional 100 megabit limit, data transmission is not stuck
•Broadcom high-end chip, performance is more stable and powerful: Broadcom high-end chip
can greatly improve network data processing rate
•Support DHCP: Support DHCP server, DHCP relay, DHCP Snooping
•Support Apollo cloud platform one-stop management: Support cloud platform to visualize
management of switches and PDs connected to the PD, making operation and maintenance
management easier
1.3 Product Software and Hardware Specifications
Sensor
Broadcom high performance sensor
Flash
16MB
Memory
256MB DDR
Ports
48 x 10/100/1000Mbps RJ45 ports
4x 10GSFP+ Fiber ports
1 Console ports, 1 Mini USB console port
Perfor
mance
Mode:Storage/ forwarding
Total Bandwidth:176Gbps
Transmission Rate:131Mpps

5
Mac address: 16K
Surge
proof
±6KV
ESD
Contact:±6KV Non-contact:±8KV
Power
in
100-240V/50-60Hz
Dimen
sion
(L×W
×H)
440mm×365mm×44mm
Software Features
Basic AI
Functions
Support hardware watchdog, restore factory Settings, system and port LED
Support global information, statistics, log information
Support user management, alarm management, configuration management
Support port rate, duplex, flow control, maximum frame length
configuration
Support port mirroring, port speed limit, port energy saving
Apollo Cloud
one stop
management
Support three management methods: local management, cloud
management, mobile management
prevention in advance; Real-time map, fast fault location; Cloud operation,
maintenance, configuration, upgrade batch processing; Multi-user, multi-
dimensional authority, hierarchical control; AI blessing, intelligent
scheduling; Business analysis and decision making; Open interface,
customer business import; Support for automatic identification,
management and acquisition of information about the downlink device
Protocol
standard
IEEE 802.3: Ethernet media access control (MAC) protocol
IEEE 802.3i:10BASE-T Ethernet
IEEE 802.3u:100BASE-TX Fast Ethernet
IEEE 802.3ab:1000BASE-T Gigabit Ethernet
IEEE 802.3z:1000BASE-X Gigabit Ethernet(Fiber)
IEEE 802.3ad: Standard method for performing link aggregation
IEEE 802.3x: traffic control
IEEE 802.1p: LAN layer 2 Qos/Cos protocol on traffic priority (multicast
filtering function)
IEEE 802.1q:VLAN Bridge operation
IEEE 802.1d:STP spanning tree
IEEE 802.1s:MSTP Multiple spanning tree
IEEE 802.1w:RSTP Fast spanning tree

6
IEEE 802.1x: Access control and authentication
G.8032: ERPS Ethernet loop protection switch
Layer 3
interface
Support Layer 3 interface
Support IPv4、IPv6 Address configuration
Support ARP configuration
Support ND configuration
Router
Supports RIP V1/V2, OSPFv1\OSPFv2 dynamic routing
Support static routing
DHCP
Support DHCP server
Support DHCP relay
Support DHCP Snooping
VLAN
Support 4K numbers of VLAN
Support 802.1Q VLAN、MAC VLAN, IP VLAN
Voice VLAN
MAC address
list
According IEEE 802.1dstandard
Support MAC address automatic learning and aging
Support static, dynamic, filtering address table
Security
Password protection
Support user access based on port number, IP address, and MAC address
Support HTTPS、SSL V3、TLS V1、SSH V1/V2
Support IP-MAC-PORT ternary binding
Support ARP protection, IP source protection, DoS protection
Support DHCP Snooping and DHCP attack protection
Support 802.1X authentication, AAA
Support port security, port isolation
Support CPU protection
(ACL)
Support L2(Layer 2)~L4(Layer 4) Packet filtering
Support port mirroring, port redirection, flow rate limiting, QoS re-marking
(QoS)
Support 8 ports queues
Support port priority, 802.1P priority, DSCP priority
Support SP, WRR, WFQ priority scheduling algorithm
Supports automatic identification, management, and retrieval of
information about attached devices

7
Spanning tree
Support STP(IEEE 802.1d),RSTP(IEEE 802.1w)and MSTP(IEEE 802.1s)
protocol
Support loop protection, root bridge protection, TC protection, BPDU
protection, BPDU filtering
Multicast
Support IGMP v1/v2 Snooping
Support fast leave
Support multicast VLAN
Supports multicast filtering, packet statistics, and unknown multicast
discards.
Storm resist
Support multicast resist
Support broadcast resist
Support for unknown unicast resist
Link
aggregation
Support static link aggregation
Support dynamic link aggregation
Support IP, MAC, hybrid load balancing mode
Max support 32 link aggregation groups
IPv6
Support IPv6 Ping、IPv6 Tracert、IPv6 Telnet
Support IPv6 SSH 、IPv6 SSL
Management
and
maintenance
Support web management (HTTP, HTTPS、SSL V3)
Support CLI(Telnet、SSH V1/V2、local ports )
Support SNMP V1/V2/V3
Support LLDP, RMON
Support ARP protection、IP source protection 、DoS protection
Support CPU monitor、Memory monitor
Support Apollo one stop management
Support system log, grading warning
Support Ping, Tracert detection, cable detection
1.4 Product appearance
Front panel
Contains indicator light, RJ45 port as shown below

8
Indicator light
The working information of the NX-5610-48GPindicator is as shown in the following table.
Indicator
light
Indicator
light
instruction
normal
status
Abnormal and trouble shooting
PWR
Indicator
light
Power
Indicator
light
Yellow
light
lighting
If the light does not illuminate, check if the
power supply of the external power outlet is
normal, and the power adapter is connected
correctly.
Link
Indicator
light
Connection
Indicator
light
Yellow
light
lighting
If the indicator is not light, check whether the
corresponding network port is connected to
the network device, the network cable is
connected correctly, the network cable meets
the standard (the maximum transmission
distance of Category 5 is 100 meters), whether
the network cable is damaged, and whether
the network device is damaged.
SYS
Indicator
light
System
Indicator
light
Green
light
flashing
If the light is off, the device does not start
normally, please restart after power off.
10GIndicat
or light
(XG1-XG4)
Connection
indication
Green
light
lighting
If the indicator is not light, check whether the
corresponding interface is connected to the
network device, the optical module is
damaged, and the network device is damaged.
RJ45ports
The NX-5610-48GPsupports 48 10/100/1000Mbps adaptive RJ45 ports. Rear panel
Includes: power outlet, power switch, ground terminal

9
SFP port
The NX5610-48GP provides four 10 Gigabit SFP optical module expansion slots for plugging into
Gigabit SFP modules.
Console port
The Console port is used to connect to the serial port of a computer or other terminal to manage
or configure the switch.
Power socket
The power supply to the switch NX-5610-48G must be 100-240V~ 50/60Hz AC power.
Chapter 2 Hardware Connection
2.1 Connecting RJ45 port
Connect the switch and the RJ45 port of the peer network device with a network cable.
2.2 Connecting SFP Ports
The SFP port of the NX-5610-48G supports only 10 Gigabit fiber modules. It is recommended
to use standard SFP module products.
The process of installing a fiber module on a switch is as follows:
1、Grasp the fiber module from the side and insert it smoothly along the SFP port
slot of the switch until the fiber module is in close contact with the switch;
2、Confirm the Rx and Tx ports of the fiber module when connecting. Insert one
end of the fiber into the Rx and Tx ports to ensure that the Tx and Rx ends of the
interface are correctly connected, and the other end of the fiber is connected to
another device.
3、After power-on, check the status of the corresponding indicator. If the indicator
is on, the link is up. If the indicator is off, the link is down. Check the line and confirm
that the peer device is enabled.
Note:
•It is not allowed to excessively bend the fiber, and its radius of curvature should be no less
than 10cm ;
•Ensure the cleanliness of the fiber end face;
•Please do not look directly into the fiber optic connector with your eyes, as this may cause eye
damage.
2.3 Check before power-on

10
Check that the power supply of the power outlet meets the switch specifications.
Check that the power supply, switch, and rack are properly grounded.
Check whether the switch is connected to other network devices.
2.4 device initialization
The switch will automatically initialize after the power is turned on and the power switch is turned
on.
The indicator light will appear as follows:
1、After the power is turned on, the power indicator remains steady. When SYS enters the
flashing state, the system runs normally.
2、The indicator of each port indicates the connection status of each port, indicating that the
switch has started to work normally.
Chapter 3 Product Installation
3.1 Installation Precautions
Note: To avoid damage to the equipment and personal injury caused by improper use, please
observe the following precautions.
Safety Precautions
•Power supply remains off during the installation process. Wear an ESD-preventive wrist strap
and ensure that the ESD-preventive wrist strap is in good contact with the skin to avoid
potential safety hazards.
•Switch only can work normally under the correct power supply. Please confirm that the power
supply voltage matches the voltage indicated by the switch.
•Before powering on the switch, please make sure that the power circuit is not overloaded, so as
not to affect the normal operation of the switch and cause unnecessary damage.
•To avoid the risk of electric shock, do not open the case while the switch is working, even if it is
not charged, do not open it yourself
•Before cleaning the switch, first pull out the power plug of the switch. Do not wipe with a moist
fabric. Do not use liquid to clean.
Humidity

11
In order to ensure long-term stable operation of the switch and prolong its service life, please
maintain a certain temperature and humidity in the environment. Too high or too low ambient
humidity is likely to cause leakage, deformation and even corrosion of metal parts. If the
temperature is too high, the aging process of the insulation material will be accelerated, which will
seriously affect the service life of the equipment. The normal operation and storage
temperature / humidity of this series of switches are as follows
Environmental
description
temperature
Relative humidity
Working Temperature
0℃~40℃
10%~90% RH Non-condensing
Storage Temperature
-40℃~70℃
5%~90% RH Non-condensing
Elevation
Products with this mark are only suitable for safe use in areas below 2000m above sea level .
Dustproof
Dust falling on the surface of the switch can cause electrostatic adsorption and poor contact of the
metal contacts. Although the device itself has made certain measures in anti-static, when the static
electricity exceeds a certain intensity, it will still cause fatal damage to the electronic components
on the internal circuit board. To avoid the static electricity affecting the normal operation of the
device, please pay attention to the following:
1、Regular dust removal to keep indoor air clean;
2、Make sure that the equipment is well grounded to ensure the smooth transfer of static
electricity.
Interference
Electromagnetic interference will affect the electronic components such as capacitors and inductors
inside the device by means of capacitive coupling, inductive coupling, impedance coupling, etc. To
reduce the adverse effects caused by electromagnetic interference, please pay attention to the
following:

12
1、The power supply system takes necessary measures against grid interference;
2、The switch should be away from high-frequency, high-power, high-current equipment,
such as wireless transmitters;
3、Take electromagnetic shielding measures when necessary.
Lightning Protection Needs
When a lightning strike occurs, a strong current is generated in an instant, and the air in the
discharge path is instantaneously heated to 20,000 degrees Celsius, and an instantaneous large
current is enough to cause fatal damage to the electronic device. For better lightning protection,
please note the following:
1. Confirm that the rack is in good contact with the ground;
2. Make sure the power outlet is in good contact with the ground;
3. Reasonable wiring to avoid internal induction lightning;
4. When using outdoor wiring, it is recommended to use a signal lightning arrester.
Installation rack requirements
Regardless of whether the switch is installed in a rack or other horizontal workbench, please note
the following:
1. Verify that the rack or table is stable, strong, and capable of withstanding a weight of at
least 5.5 kg;
2. Confirm that the rack itself has a good cooling system, or keep the room well ventilated;
3. Make sure the rack is well grounded, and the distance between the power socket and the
switch is less than 1.5 meters.
Tool Preparation
The Phillips screwdriver, electrostatic wrist strap, and cable fiber may be used during installation.
3.2 Product Installation
19 inch standard rack mount
The NX-5610-48GP is designed to fit the standard 19-inch rack and can be easily mounted to
the rack. The specific installation steps are as follows::
1. Check the grounding and stability of the rack;

13
2. Install the two L-shaped brackets in the accessories on both sides of the switch panel and fix
them with the screws provided in the accessories.
3. Place the switch in the proper position in the rack and support it by the bracket. Fix the L-
bracket to the guide groove fixed at both ends of the rack with screws to ensure that the
switch is installed on the rack stably and horizontally.
Note:
Good grounding of the rack is an important guarantee for anti-static, anti-leakage, lightning
protection and anti-interference of the equipment. Therefore, ensure that the grounding wire of
the rack is properly installed.
The equipment installed in the rack is generally from bottom to top to avoid overload installation;
Avoid placing other heavy objects on the surface of the switch to avoid accidents;
Ensure heat dissipation and air circulation.
3.3 login management interface
Step1
Connect the network cable to the computer
Step 2
Change the computer IP to 192.168.254.X (2~254), and the Subnet mask is 255.255.255.0

14
Step3
Turn on the browser, input 192.168.254.1, and click Enter
Step4
Enter the web manage UI, Input the Username and PW, both are admin and log in
Step5
You already entered the web management UI of the switch and can start to configure the switch
.
Chapter 4, packing list and recommendations for use
4.1Open the package and check the list below.
Objects
Quantity
Remark
Switch
1 pc
\
Power cable
1 pc
Support power to SW

15
Hook
2 pcs
To installation
Warranty
Card
1 pc
To After sale service
Manual
1 pc
To guide the user
4.2 Suggestions
1. For safety reasons, non-professionals should not open the product case;
2. Pay attention to the danger of strong electricity and safe protection when the
product is powered on;
3. Please select the correct power adapter to supply power to the switch. Confirm
whether it meets the switch requirements before use;
4. Do not use the switch in a humid environment to prevent water from entering the
fuselage through the casing, resulting in damage to the machine.;
5. Please turn on the power after the line connection is completed;
6. When the product is powered on, please do not plug and unplug the cable if it is not
special.
7. Do not use the switch in places with excessive dust and electromagnetic radiation.
Do not use the switch in a place that is hot and not ventilated.;
8. Please do not place heavy objects on the switch to avoid accidents.;
9. It is recommended to use the switch indoors. It is recommended to add a
waterproof box when using it outdoors.
Note: The pictures in the manual are for reference only, whichever is subject to the
actual products.
Table of contents
Other NODEXON Switch manuals
Popular Switch manuals by other brands

NETGEAR
NETGEAR GSM7248R - ProSafe Switch Supplement

BENZING
BENZING Live SMART HUB quick start guide

Ross
Ross Carbonite Black Setup manual

Edimax
Edimax ES-516G+ Specifications

Intermatic
Intermatic ET279C Owner/installer instruction manual

Centrepoint Technologies
Centrepoint Technologies TalkSwith user guide

Fastcabling
Fastcabling PoE Powered Switch Guide

Digitus
Digitus DN-95315 Quick installation guide

Tycon Power Systems
Tycon Power Systems TP-SW8(-NC) user manual

Knoll
Knoll UTP install guide

Lantronix
Lantronix SISPM1040-2248-L3 quick start guide

Motorola
Motorola DIMETRA MTS 4 Installation, configuration, and service guide