NookBox MDC-1 User manual

1NookBox Installation Guide Mini Door Contact MDC-1
Mini Door Contact
(MDC-1)
Installation Guide

2NookBox Installation Guide Mini Door Contact MDC-1
The Mini Door Contact monitors the opening/closing of specied devices (e.g. door or win-
dow). The Door Contact is xed to the monitored device frame with an actuating magnet xed
to the device. When the door or window opens, the magnet moves away from the Door Con-
tact, activating an internal magnetic switch causing the Door Contact to transmit alarm signal
to the Control Panel. The device also has the capabilities of communicating signal problems
along with low battery situations.
The Door Contact design is consisted of a front cover and a back cover. The front cover (back)
contains all electronics and the back cover provides a means for xing the device. An enclo-
sed PCB tamper switch provides tamper protection against unauthorized device opening.
Mini Door Contact
(MDC-1)

3NookBox Installation Guide Mini Door Contact MDC-1
Identifying the parts
1. Rib Marks
2. Battery Insulator
3. Learn / Testbutton
-Press the Test button to transmit a learn code.
-Press the Test button once to enter Test Mode for 3 minutes.
4. Red LED Indicator
5. Tamper Switch
6. Battery
7. Mounting Holes (Knockouts)
8. Tamper Compression Mark
9. Magnet
10. Magnet Spacer
Accessories Included
a) 1 Magnet
b) 1 double-sided adhesive Magnet Spacer
c) 2 Screws
d) 4 Wall Plugs
e) 1 double-sided adhesive Velcro tape (for Door Contact)
f) 1 double-sided adhesive tape pad (for Magnet)
g) 2 Magnet mounting screws

4NookBox Installation Guide Mini Door Contact MDC-1
Features
LED Indicator
In Normal operation mode, the LED indicator remains o except in the following situations when:
• When Door Contact’s Tamper switch is triggered.
• When the Door Contact is activated with either Tamper or Low battery condition.
• When the Door Contact is activated and transmitting the signal under the Test mode.
Supervision
• The Door Contact will automatically transmit Supervisory signals periodically to the Control Panel at random intervals of 30 to 50 minu
tes in Normal Operation Mode.
• If the Control Panel has not received the signal from the Door Contact for a preset period time, the Control Panel will indicate that parti
cular Door Contact is experiencing an out-of-signal problem.
Tamper Switch
• It is designed to protect against unauthorized, cover opening. When the tamper is triggered, Door Contact will emit a signal to the
Cotrol Panel for reporting, the LED will also light up.
Battery
The MDC-1 uses one 3V CR2032 Lithium battery as its power source,
The Door Contact is also capable of detecting low battery. When the battery is low, a low battery signal will be sent to the Control Panel along
with regular transmission. The LED will light up when the Door Contact is activated under low battery status.
• Changing Battery
You need to open the cover to insert/remove the battery
After the battery has been removed, press the Learn / Test button 5-6 times to fully discharge before inserting the new battery.
NOTE:
• Make sure the battery mark with the positive side (+) is faced upwards when inserting the battery.
• Make sure to insert or place the battery from the top right angle in the Front Cover (Back) view:
Test Mode
The Door Contact can be put into Test mode for 3 minutes by pressing the Test Button on the front cover (back) once. During Test mode, the
LED indicator will turn on upon triggering. Each press on the Test Button, the Door Contact will transmit a test signal to the Control Panel for
radio range test and resets the test mode back to the 3-minute duration. It will exit Test Mode automatically after the 3 minutes and returns to
Normal Operation mode.
Getting Started
Step 1: Remove the battery insulator located at the rear side of the Door Contact.
Step 2: Put the Control Panel into learning mode, refer to Control Panel manual for detail.
Step 3: Press the Learn/Test Button on Door Contact to send signal to the Control Panel.
Step 4: If the Control Panel successfully receives the signal, the Control Panel should respond (e.g. emitting beeps).
Refer to your Control Panel manual to complete the learning process.
Step 5: After the Door Contact is learnt-in, put the Control Panel into “Walk Test” mode, hold the Door Contact at the desired location,
and press the Test button to conrm if this location is within signal range of the Control Panel.
Step 6: When you are satised with the Door Contact at the chosen location, proceed to installation.

5NookBox Installation Guide Mini Door Contact MDC-1
Installation
To open the cover of the Door Contact:
Step 1. Use a at-headed screwdriver to t into the cover opening hole on one side as (Pic1).
Step 2. Push the at-headed screwdriver upwards as (Pic2).
Step 3. Turn to the other side and repeat Step 1 and Step 2.
Step 4. Once opened the cover, you can proceed to change the battery etc.
Step 5. To replace the cover:
- Make sure the Tamper Compression Mark is aimed at the Tamper Switch (Pic 3).
- Also make sure the bottom hooks of the back cover is latched on the bottom of the front cover (back) as (Pic 4)
- Fit the bottom hooks into the bottom latches of the front cover (back) then push it downwards as (1) in (Pic 5), then
push forward (2) the entire back cover to close it until you hear a clip sound.
Mounting Methods
• Mount the Door Contact using one of the below mounting methods: Velcro tape Mounting and Screw Mounting.
• Mount the magnet on the more mobile object (such as door) using either the smaller double-sided adhesive pad or the screws provided.
• Align the magnet according the rib mark on Door Contact. Where required, use the Magnet Spacer to better align the magnet to the rib
marks. The magnet should be no more than 15mm from the detector when the door is closed.

6NookBox Installation Guide Mini Door Contact MDC-1
Mounting Methods for the Door Contact
Screw Mounting
The back cover has two Mounting Holes (knockouts), where the plastic is thinner, for mounting purpose.
To mount the Door Contact:
1. Remove the cover (See Installation above).
2. Break through the knockout on the back cover.
3. Using the holes as a template, drill both holes.
4. Insert wall plugs if xing into plaster or brick.
5. Screw the back cover into the wall plug using a Philips screwdriver.
6. Attach the front cover to the back cover (see Pic 3 ~ 5 above).
Velcro Tape Mounting
The Door Contact can be wall mounted using Velcro tape provided.
1. Clean the wall mounting location and back of the Door Contact with degreaser. Do not mount on wall with
cracking paint or rough surface.
2. The Velcro tape can be separated to Hook and Loop side (Pic 6.).
3. Remove the protective cover of the Hook side and attach to the back of the Door Contact. Press rmly for
30 seconds to ensure good contact. (Pic 7.)
4. Remove the protective cover of the Loop side and apply to desired mounting location as in (Pic 8.) Press
rmly for 30 seconds to ensure good contact.
5. Apply the Door Contact on the Loop side Velcro taped on the wall (Pic 9 & 10.)

7NookBox Installation Guide Mini Door Contact MDC-1
Mounting Methods for the Magnet
Screw Mounting
The back cover of the magnet has two Mounting Holes for mounting purpose.
To mount the Magnet:
1. Open the back cover by using a at-headed screwdriver to t into the caved in area and push upwards.
2. Using the holes as a template, drill both holes.
3. Screw the back cover into the door/window using a Philips screwdriver. Where required, use the Magnet
Spacer to better align the magnet to the rib marks.
4. Attach the front cover to the back cover. If the front cover is stabilized onto the back cover, you should
hear a Click sound.
Adhesive Mounting
The back cover of the magnet has two Mounting Holes for mounting purpose.
To mount the Magnet:
The Magnet can also be mounted using the double-sided adhesive tape pad or the double-sided adhesive Magnet
Spacer.
I. Clean the mounting location and back of the Magnet with a suitable degreaser.
II. Remove the protective covering from one side of the pad or the double-sided adhesive Magnet Spacer.
Apply to the back of the Magnet and press rmly for 30 seconds to ensure good contact.
III. Remove the other cover and rmly press the Magnet onto the desired location for 30 seconds.
NOTE: Please do not re-apply the double-sided adhesive tape pad or the double-sided adhesive Magnet Spacer. They cannot be reused

8NookBox Installation Guide Mini Door Contact MDC-1
For more information visit:
www.getnookbox.com
Table of contents
Popular Controllers manuals by other brands

WAGO
WAGO PFC200 2ETH RS XTR manual

Johnson Controls
Johnson Controls VA9310 Series installation instructions

Gefen
Gefen EXT-CU-LAN Setup guide

Auber
Auber WS-1500FXL Operation & instruction manual

Horstmann
Horstmann ChannelPlus H37VXL Series 2 User operating instructions

Cypress
Cypress CY8C20xx7/S CapSense Series Design guide