Norac UC5 ECHO Display Kit User manual

ECHO Display Kit - Loane
r
Installation Manual
ECHO-DT1L

Printed in Canada
Copyright 2010 by NORAC Systems International Inc.
Reorder P/N: ECHO-DT1L-INST Rev B (ECHO Display Kit - Loaner)
NOTICE: NORAC Systems International Inc. reserves the right to improve products and their specifications without notice and
without the requirement to update products sold previously. Every effort has been made to ensure the accuracy of the information
contained in this manual. The technical information in this manual was reviewed at the time of approval for publication.

1
Contents
1INTRODUCTION..................................................................................................... 2
1.1List of Parts..........................................................................................................................................................................2
2TECHNICAL SPECIFICATIONS ............................................................................ 3
3INSTALLATION........................................................................................................ 4
3.1Installation with Control Module Serial Number 3200 and Lower .........................................................................4
3.2Installation with Control Module Serial Number 3199 and Lower .........................................................................5
4CABLE DRAWINGS ................................................................................................. 6
4.1ITEM C01: 43220-01 - CABLE UC5 NETWORK 14 AWG - 1M ...........................................................................6
4.2ITEM C01: 43220-0.5 - CABLE UC5 NETWORK 14 AWG – 0.5M ......................................................................6

2
1Introduction
The ECHO™ Display Kit Manual is intended to be used in conjunction with the UC5™ Spray
Height Control Installation Manual. This manual provides instructions to interface the UC5
Control Module to the ECHO Display. For installation of the rest of the UC5 Spray Height
Control System please refer to the sprayer specific manual provided with the kit.
Your input can help make us better! If you find issues or have suggestions regarding the parts
list or the installation procedure, please don’t hesitate to contact us.
1.1 List of Parts
Item Part Number Name Quantity
C01 43220-01 CABLE UC5 NETWORK 14 AWG 1M 2
C02 43220-0.5 CABLE UC5 NETWORK 14 AWG 0.5M 1
D01 43700 UC5 ECHO DISPLAY PANEL 1
E10 43760 UC5 NETWORK COUPLER 3-WAY 1
E20 43764T UC5 NETWORK COUPLER 2-WAY WITH TERMINATOR 2
E21 43250-10 UC5 NETWORK POWER JUMPER 1
M01 UC5-BC-MANUAL-ECHO-VT MANUAL UC5 OPERATORS - ECHO/VT 1
M04 ECHO-DT1L-INST MANUAL UC5 ECHO TERMINAL DISPLAY KIT - LOANER 1

3
2Technical Specifications
CAN ICES-3(A)/NMB-3(A)
This device complies with part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must accept
any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class A digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio frequency energy and, if not
installed and used in accordance with the instruction manual, may cause harmful interference to
radio communications. Operation of this equipment in a residential area is likely to cause
harmful interference in which case the user will be required to correct the interference at their
own expense.
This Class A digital apparatus complies with Canadian ICES-003.
Pursuant to EMC Directive – Article 9, this product is not intended for residential use.
Table 1: System Specifications
Supply Voltage (rated)
12VDC
Supply Current (rated)
10
A
Hydraulic Pressure (maximum)
3300 psi
Baud Rate 250 kbps
Clock Frequency (maximum)
96 MHz
Solenoid Valve PWM Frequency
300 Hz
Ultrasonic Sensor Transmit Frequency
50 kHz
Operating Temperature Range
0°C to 80°C

4
3Installation
Ensure the ECHO power switch is OFF for the remainder of the installation (Bottom of
switch pressed IN).
There are two different ways that the ECHO can be installed depending on the serial number
of the control module (part #43710). Follow the instructions that match the control module
serial number.
3.1 Installation with Control Module Serial Number 3200 and Lower
1. Connect the cable from the ECHO display (D01) to one of the couplers (E20) and connect
one of the network cables (C01) to the other side of the coupler. Connect the remaining
coupler (E20) between the two network cables (C01).
2. Connect the free end of the second network cable (C01) to the Display Bus connector on
the control module (E01). This is the end of the control module that only has one Deutsch
connector.
Figure 1: ECHO Display Kit Parts

5
3.2 Installation with Control Module Serial Number 3199 and Lower
1. For this type of installation the power jumper (E21) will need to be installed.
2. Connect the cable from the ECHO display (D01) to one of the couplers (E20) and connect
one of the network cables (C01) to the other side of the coupler. Connect the remaining
coupler (E20) between the two network cables (C01).
3. Connect the free end of the second network cable (C01) to the Display Bus connector on
the control module (E01). This is the end of the control module that only has one Deutsch
connector.
4. Disconnect the network cable from the control module NORAC bus (end of control
module with two Deutsch connectors).
5. Connect the 3-way coupler (E10) to the disconnected network cable. Connect cable C02
between the 3-way coupler and the control module.
6. Insert the power jumper (E21) into the remaining connector on the 3-way coupler.
Figure 2: Power Jumper Installation
Only parts shown in black are included in this kit. Parts shown in blue are existing
parts.

6
4Cable Drawings
4.1 ITEM C01: 43220-01 - CABLE UC5 NETWORK 14 AWG - 1M
4.2 ITEM C01: 43220-0.5 - CABLE UC5 NETWORK 14 AWG – 0.5M

Canada
NORAC Systems International Inc.
Phone: (+1) 306 664 6711
Toll Free: 1 800 667 3921
Shipping Address:
3702 Kinnear Place
Saskatoon, SK
S7P 0A6
United States
NORAC, Inc.
Phone: (+1) 952 224 4142
Toll Free: 1 866 306 6722
Shipping Address:
6667 West Old Shakopee Road, Suite 111
Bloomington, MN
55438
Europe
NORAC Europe
Phone: (+33) (0)4 26 47 04 42
Shipping Address:
Rue de l’hermitage
01090 GUEREINS
France
www.norac.ca
Other manuals for UC5 ECHO Display Kit
1
This manual suits for next models
1
Table of contents
Popular Control Panel manuals by other brands

Honeywell
Honeywell NOTIFIER RP-2002C instruction manual

nilan
nilan CTS6000 user guide

Mitsubishi Electric
Mitsubishi Electric GOT 900 operating manual

DMP Electronics
DMP Electronics XR5FC Programming guide

Panasonic
Panasonic AK-HRP200GJ operating instructions

American Pro
American Pro NAVIGATOR 2000 user manual

Mitsubishi
Mitsubishi GT2512-STBA General description

NAPCO
NAPCO GEMINI C Series installation instructions

Maple Systems
Maple Systems cMT3092X Series Installation instruction

RHINO
RHINO 816 user manual

Kingspan
Kingspan iVent 8A Technical information and operating instruction

GJD
GJD HYL004 Installation & programming guide