manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Norcon Communications
  6. •
  7. Conference System
  8. •
  9. Norcon Communications TTU-1X Series User manual

Norcon Communications TTU-1X Series User manual

TTU® -1X Series 2-Way Talk-Thru Electronic
Communication System.
Avoice communications system for High-Security and Isolation
Booth Situations. In today’s security conscious environment,
isolation booths are often the ideal recourse to protect your
employees. But doesitfacilitate and help maintain your very
important public image? Not ifclerks and customers have to yell and
repeat themselves to be heard or understood.
The Patented TTU® -1XTalk-Thru Communicator is a 2-way,
hands-free audio system that provides high-quality personal
communication between people separated by security or isolation
barriers. Itisthe most widely used system ofits type in the U.S., and
the world.
FEATURES
•Clear 2-way hands-free voice communication.
•Quality electronic design and engineering.
•Avoid raising your voice, repetition & misunderstanding.
•XLR removable mic for your convenience.
•Simple, one-person installation.
•Rugged, tamper-resistant materials. Anodized aluminum
•Self-powered with fast rechargeable battery option.
•Bullet-resistant option (UL level 3).
•Units available for ADA applications.
•Headset jack equipped on all models. Headset can be ordered
separately.
•Export models available
1
HOW IT WORKS …
The Norcon TTU® system permits hands-free, 2-way
communication between the booth attendant and the customer.
Unique circuitry facilitates ongoing, clear, 2-way conversation at all
times – as if the two parties were together in the same room. The
TTU®-1X Talk-Thru Communicator now incorporates circuitry to
automatically attenuate the outside channel. If the gooseneck
microphone is not used for a period of 30 seconds, the outside
channel volume will be reduced approximately 70%. Normal operation
is restored as soon as the attendant speaks into the gooseneck
microphone. The automatic volume attenuation circuit prevents
outside noise from bothering the attendant.
The TTU® -1X provides clear communication even in
environments with high ambient noise by shaping the sound for
maximum intelligibility. Its compression circuitry decreases loud,
annoying sounds.
HOW TO INSTALL …
Installation of the TTU® -1X is a very simple, one-person operation.
All that’s needed is a 3” to 4” diameter cutout in the barrier. Four
fasteners and two rubber gaskets for mounting are supplied. The front
face and housing are easily mounted on opposite sides of the barrier
using the fasteners. The rubber gaskets prevent slippage and protects
the barrier surface. The electronic section is then inserted into the
housing and fastened in place.
2
Installation Instructions:
Remove the four (4) 6-32 assembly screws.
Separate the housing and electronics assembly.Unplug
electronic assembly from the faceplate and housing.
Set the electronic assembly aside, carefully.
Remove the four (4) 8-32 mounting nuts from the mounting rods.
Separate the faceplate and housing. Discard the shipping spacers
located between the faceplate and housing if there are any. Hold the
faceplate over the partition opening. Carefully center the faceplate and
align the lettering horizontally. Masking tape can be used to temporarily
hold the faceplate to the outside of the partition.
On the inside of the partition mount the housing over the four (4)
8-32 mounting rods. Be certain to position the housing so that the
threaded hole is positioned properly. If using tubing, orient the hole in
the direction which the tubing is to exit (left, right, top, and bottom). If
tubing is not being used, place the plugged hole at the bottom.
Recommended cables for wiring :
For power connections use West Penn wire #221.This isa
stranded single pair 22 awg, Plenecon -IIjacket Rohs cable. Keep
Mic/spk and power cable bundles away from other power cable.
For power connection, route the one pair cable (with the connector
on one end). From the inside unit tothe location of the PS-1 power
supply. Connect the conductors tothe power supply (RED to +ve,
BLACK to -ve). Plug the connector to its mate from the printed
circuit board. Connect 4 – pin polarized connectors and reassemble
units
3
Place the housing so that the threaded hole can be positioned
properly. If using tubing, orient the hole in the direction in which the
tubing is to exit as shown in the drawing.
HOW TO USE THE TALK-THRU COMMUNICATOR...
1. With power switch off, turn Talk and Listen controls
completely counter clockwise.
2. Turn on the unit by switching the Power ON/OFF switch to its
upper position. At this position, the unit is at the auto mute
mode.
3. Adjust the TALK volume control until the attendant is clearly heard
by the person outside the window when the attendant is speaking 2"
to 4" from the gooseneck microphone at a normal speaking level. The
green LED should go on when the attendant starts talking and go off
when the attendant stops talking.
If the green LED stays lit
constantly, it indicates either the TALK volume setting or the
ambient noise is too high.
4. Adjust the LISTEN control until the person outside the window is
clearly heard when speaking at a normal level.
4

OPERATION HINTS:
1. Increasing the talk volume control allows the attendant to
speak further away from the microphone as well as increasing
the talk channel volume. The optimum distance from the
microphone should be maintained at approximately 2”-4” or
conversations not directed to customers may be heard outside
the booth. Watch the green LED above the TALK volume
control, it should be ON only when talking into the gooseneck
microphone and off when not talking to the microphone.
2. Installing a headset into the Headset jack will allow
communications from the headset and disconnect the speaker
and the gooseneck microphone.
3. The unit will decrease the incoming volume level by
approximately 70% some 30 seconds after the attendant stops
speaking into the microphone. The purpose of this feature is to
decrease the amount of extraneous noise entering the booth.
Normal volume level is restored when the attendant speaks
into the microphone. The muting function can be defeated by
switching the POWER SWITCH to the NO MUTE position.
5
SPECIFICATIONS:
MECHANICAL:
•Outside faceplate: Aluminum, anodized finish, tamper-resistant.
•Control housing (inside): Machined aluminum, anodized finish,
tamper-resistant.
•Size: Outside faceplate 5” Dia. x ½” D. Inside control housing:
5” Dia. x 2-1/2” D (TTU®-1 AX) (TTU®-1 AX)
5” Dia. x 3-1/2” D (TTU®-1 D X) (TTU®-1 ABX)
•Weight: ~ 5 LB.
•Mounting: Partition hole 3 to 4” Dia. (3-1/2” recommended)
Specify barrier thickness when ordering. Norcon will adjust
the length of the mounting rods to meet your need.
Panel Controls: LISTEN volume, TALK volume, POWER On/Off,
AUTO MUTE On/Off.
ELECTRONIC:
•Audio frequency response: Selectively shaped for maximum voice
intelligibility.
•Audio power: 2 watts per amplifier.
•Distortion: Less than 2%.
•Listen mode: 20dB compression.
•Microphone: Electret.
•Power Supply Adapter: Input 90-240V AC, 60 Hz. Output 15V
DC, 1A. UL, (Canada and US) CE, level VI.
Specifications are subject to change without notice.
6TTU-1A XLR P.1.
Be certain to position the housing so that the threaded hole can
be positioned properly. If using tubing, orient the hole in the
direction which tubing is to exit.
TROUBLESHOOTING:
You may occasionally encounter a problem with your TTU® system. If
this happens, refer to the trouble shooting list. If additional help is
needed, please contact us.
No sound at all
•Is the power cable properly connected to power supply and
the power supply plugged into a working outlet?
The power cable red wire should be connected to (+) and black wire
connected to (-) the power supply. The power supply should has been
has been plugged into a working outlet.
Howling ( Feedback)
•Is the TALK or LISTEN volume turned too high?
Set the volume control to a proper level. In most cases, both TALK and
LISTEN controls should be set to the position of around 11 to 12o’clock.
Conversation cutting-off and breaking-up
•Is the TALK volume setting too high?
Turn down TALK volume to a proper level. Make sure the green LED is
off when not talking to the gooseneck microphone.
•
Is the attendant talking too far from the gooseneck
microphone?
The idea distance is 3” to 4” from the gooseneck microphone.
TTU®-1 DX does not work when operated by internal battery.
•Are the batteries fully charged?
If the unit is newly installed, allow the batteries to be charged for 10-12
Hrs. before operating. The unit can be used while the batteries are
being charged.
•Is the battery charger plugged into a working outlet?
If the battery charger is plugged into a working outlet, and the batteries
are being charged, the battery charger should be warm, if it is not; the
battery charger may be defective.
7
12

Other manuals for TTU-1X Series

1

Other Norcon Communications Conference System manuals

Norcon Communications TTU-7X User manual

Norcon Communications

Norcon Communications TTU-7X User manual

Norcon Communications TTU-1X Series User manual

Norcon Communications

Norcon Communications TTU-1X Series User manual

Popular Conference System manuals by other brands

Logtech SmartDock Setup guide

Logtech

Logtech SmartDock Setup guide

Grandstream Networks UCM630 A Series user guide

Grandstream Networks

Grandstream Networks UCM630 A Series user guide

Comat Releco CMS-10R Series user manual

Comat Releco

Comat Releco CMS-10R Series user manual

New Rock Technologies WROC2000 user manual

New Rock Technologies

New Rock Technologies WROC2000 user manual

Polycom picturetel 900 series installation guide

Polycom

Polycom picturetel 900 series installation guide

Interalia XMU+ Installation handbook

Interalia

Interalia XMU+ Installation handbook

Avaya PARTNER Advanced Communications System Installation and use manual

Avaya

Avaya PARTNER Advanced Communications System Installation and use manual

NEC Univerge SV9100 User reference guide

NEC

NEC Univerge SV9100 User reference guide

PEIKER CEE CEE COACH manual

PEIKER CEE

PEIKER CEE CEE COACH manual

Power Dynamics TG40T instruction manual

Power Dynamics

Power Dynamics TG40T instruction manual

NEC ASPILA EX Feature manual

NEC

NEC ASPILA EX Feature manual

Crestron UC-M70-NC-Z quick start

Crestron

Crestron UC-M70-NC-Z quick start

Polycom HDX 9006 Integrator's manual

Polycom

Polycom HDX 9006 Integrator's manual

Polycom realpresence group 550 Setup guide

Polycom

Polycom realpresence group 550 Setup guide

Polycom V700 reference guide

Polycom

Polycom V700 reference guide

Bogen BOMDMU user manual

Bogen

Bogen BOMDMU user manual

Yamaha CS-700 Series quick start guide

Yamaha

Yamaha CS-700 Series quick start guide

Lenovo ThinkSmart Hub Getting started

Lenovo

Lenovo ThinkSmart Hub Getting started

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.