NORTHCLIFFE Barat LED1x1300 C101 T840 PC/PC OP IC Ex Installation instructions

BARAT LED Ex USER INSTRUCTION OF LUMINAIRE
NORTHCLIFFE LIGHTING
2015-12-14 No. BARLEDEX-151214
Subject to change without notice
BARAT LED EX
Raudondvario pl. 101, Kaunas, Lithuania.
www.northcliffe.org
Explosion Proof IP66
Luminaire for
Hazardous Zones 2, 22
Type:
Explosion proof IP66 luminaire designed for illumination of hazardous areas where an explosive atmosphere persists
for a short period. Hazardous zones: 2, 22.
Specification:
Opal (LED) UV stabilized polycarbonate diffuser. White powder coated gear tray.
Injection molded polycarbonate canopy, grey finished. Stainless steel diffuser retaining clips.
Explosion group: gas: IIC, IIB, IIA dust: IIIC, IIIB, IIIA
Protection degree: IP66
ATEX cable gland: 2xM20, 1xblanking plug
Cable diameter: 7-13mm
Ta: -25ºC to 40ºC (Ta with emergency kit: +0ºC to 35ºC)
Luminaire is plastic-wrapped and boxed individually.
Installation:
Surface luminaire is designed to be fixed to ceilings of any type or suspended. Supplied with two fixing brackets for
easy installation, sealing washer and accessories for chain and wire suspension. Installed luminaires has to be
protected from mechanical damage.
Application:
Suitable for industrial areas and facilities with a danger of flammable gas, dust and vapour explosion. Marking of
explosion-protection: II 3G Ex nA IIC T6 Gc; II 3D Ex tc IIIC T85oC Dc
If EM3

BARAT LED Ex USER INSTRUCTION OF LUMINAIRE
NORTHCLIFFE LIGHTING
2015-12-14 No. BARLEDEX-151214
Subject to change without notice
BARAT LED EX
Raudondvario pl. 101, Kaunas, Lithuania.
www.northcliffe.org
1. PURPOSE
1.1 The suspended hermetic LED luminaires are meant for explosive environments. The protection class against external factors is IP66. The luminaries are used with
the LED modules.
2. TECHNICAL CHARACTERISTICS
2.1 The luminaire is fed from the circuit of alternating current, with voltage of 220-240 V, frequency 50-60 Hz.
2.2 The main parameters and characteristics:
Table 1.
Name
Overall
dimensions
(LxWxH), mm
Lifetime, h
Luminaire
output*, lm
Ta=25ºC
System
power*,
W
CRI
(Ra)
CCT, K
kg
Barat LED1x1300 C101 T840 PC/PC OP IC Ex
662x96x111
50000
1279
12
80+
4000
1,30
Barat LED1x1900 C102 T840 PC/PC OP IC Ex
662x96x111
50000
1879
16
80+
4000
1,30
Barat LED2x1300 C104 T840 PC/PC OP IC Ex
662x146x111
50000
2558
24
80+
4000
1,80
Barat LED2x1900 C105 T840 PC/PC OP IC Ex
662x146x111
50000
3759
31
80+
4000
1,80
Barat LED1x2600 C107 T840 PC/PC OP IC Ex
1272x96x111
50000
2558
24
80+
4000
2,10
Barat LED1x3800 C108 T840 PC/PC OP IC Ex
1272x96x111
50000
3759
31
80+
4000
2,10
Barat LED2x2600 C110 T840 PC/PC OP IC Ex
1272x146x111
50000
5117
46
80+
4000
2,80
Barat LED2x3800 C111 T840 PC/PC OP IC Ex
1272x146x111
50000
7518
62
80+
4000
2,80
Barat LED1x3200 C113 T840 PC/PC OP IC Ex
1572x96x111
50000
3198
29
80+
4000
2,60
Barat LED1x4700 C114 T840 PC/PC OP IC Ex
1572x96x111
50000
4699
39
80+
4000
2,60
Barat LED2x3200 C116 T840 PC/PC OP IC Ex
1572x146x111
50000
6396
58
80+
4000
3,30
Barat LED2x4700 C117 T840 PC/PC OP IC Ex
1572x146x111
50000
9397
78
80+
4000
3,30
Barat LED Ex emergency version:
Name
Overall
dimensions
(LxWxH), mm
Lifetime, h
Luminaire
output*, lm
Ta=25ºC
System
power*,
W
CRI
(Ra)
CCT,
K
kg
Barat LED1x2600 C107 T840 PC/PC OP IC EM3 Ex
1272x96x111
50000
2558
24
80+
4000
2,70
Barat LED1x3800 C108 T840 PC/PC OP IC EM3 Ex
1272x96x111
50000
3759
31
80+
4000
2,70
Barat LED2x2600 C110 T840 PC/PC OP IC EM3 Ex
1272x146x111
50000
5117
46
80+
4000
3,40
Barat LED2x3800 C111 T840 PC/PC OP IC EM3 Ex
1272x146x111
50000
7518
62
80+
4000
3,40
Barat LED1x3200 C113 T840 PC/PC OP IC EM3 Ex
1572x96x111
50000
3198
29
80+
4000
3,20
Barat LED1x4700 C114 T840 PC/PC OP IC EM3 Ex
1572x96x111
50000
4699
39
80+
4000
3,20
Barat LED2x3200 C116 T840 PC/PC OP IC EM3 Ex
1572x146x111
50000
6396
58
80+
4000
3,90
Barat LED2x4700 C117 T840 PC/PC OP IC EM3 Ex
1572x146x111
50000
9397
78
80+
4000
3,90

BARAT LED Ex USER INSTRUCTION OF LUMINAIRE
NORTHCLIFFE LIGHTING
2015-12-14 No. BARLEDEX-151214
Subject to change without notice
BARAT LED EX
Raudondvario pl. 101, Kaunas, Lithuania.
www.northcliffe.org
Type Examination Certificate Number:
OBAC 16 ATEX….
II 3G Ex nA IIC T6 Gc; II 3D Ex tc IIIC T85oC Dc,
Type: Barat LED1x....Ex
Light source
LED module
Type of power source
LED driver
Temperature class
T6
T max. surface
850C
Type: Barat LED2x....Ex
Light source
LED module
Type of power source
LED driver
Temperature class
T6
T max. surface
850C

BARAT LED Ex USER INSTRUCTION OF LUMINAIRE
NORTHCLIFFE LIGHTING
2015-12-14 No. BARLEDEX-151214
Subject to change without notice
BARAT LED EX
Raudondvario pl. 101, Kaunas, Lithuania.
www.northcliffe.org
LT Montavimo instrukcija
LV Instalacijas intrukcija
EE Paigaldusjuhised
UK installation instruction
DE Montageanleitung
RU Инструкция по установке
PL Instukcja montazu
DK Installationsvejledning
FI Asennusohjeet
Atsargumo priemonės (LT). Montavimo darbus gali atlikti tik atestuotas elektrikas; Išjunkite elektros tiekimą prieš atliekant bet kokius darbus; Šviestuvas turi būti sumontuotas laikantis visų saugumo reikalavimų;
Dėmesio! Tikslus šviestuvo modelis pažymėtas ant etiketės jo viduje. Precautions (EN). Installation can only be performed by an authorized electrician; Switch off the electricity supply before carrying out any work;
Luminaire must be installed in compliance with all safety requirements; Attention! The exact model of the fixture marked on label inside it. Меры предосторожности (RU). Установка может быть выполнена
только квалифицированным электриком; Отключить напряжение питания перед проведением любых работ; Светильник должен быть установлен в соответствии со всеми требованиями безопасности;
Внимание! Точная модель прибора указаны на этикетке внутри него. Ettevaatusabinõud ( EST). Paigaldamise võib teostada ainult volitatud elektrik; Lülitage välja toide enne paigaldustööde alustamist; Valgusti
peab olema paigaldatud vastavalt kõigile ohutusnõuetele; Tähelepanu! Toote täpne mudel on toote etiketil. Piesardzības pasākumi (LV). Uzstādīšanu var veikt tikai kvalificēts elektriķis; Izslēdziet elektroenerģijas
padevi, pirms veikt jebkuru darbu; Gaismekļa jāuzstāda atbilstoši visām drošības prasībām; Uzmanību!Precīzs modelis statīva atzīmēti uz etiķetes tā iekšpusē; Środki ostrożności (PL). Instalacja może być
wykonywane tylko przez uprawnionego elektryka; Wyłączyć zasilanie elektryczne przed przystąpieniem do pracy; Oprawa musi być zainstalowany zgodnie ze wszystkimi wymogami bezpieczeństwa;
Uwaga!Dokładny model urządzenia oznaczone na etykiecie w środku.
1
2
3
4 Red –positive. Black –negative
5
Barat LED EX
A
B
Clips*, pcs.
Ex
Barat LED1x1300 C101 T840 PC/PC OP IC Ex
350
662
6
Ex
Barat LED1x2600 C107 T840 PC/PC OP IC Ex
700
1272
10
Ex
Barat LED1x4700 C114 T840 PC/PC OP IC Ex
940
1572
12
Ex
Barat LED2x1300 C104 T840 PC/PC OP IC Ex
350
662
6
Ex
Barat LED2x2600 C110 T840 PC/PC OP IC Ex
700
1272
10
Ex
Barat LED2x4700 C117 T840 PC/PC OP IC Ex
940
1572
12

BARAT LED Ex USER INSTRUCTION OF LUMINAIRE
NORTHCLIFFE LIGHTING
2015-12-14 No. BARLEDEX-151214
Subject to change without notice
BARAT LED EX
Raudondvario pl. 101, Kaunas, Lithuania.
www.northcliffe.org
6
7
If option ThroughWiring:
8 If Emergency:
If Through Wiring:
3LIN
1LIN
9
L ---> L1 or L2 or L3
10
11 Closing sequence:
Exploitation:
If the lens is dirty clean it with a damp cloth only
- Electrostatic sensitive devides.
Do not enter without proper static control devices

BARAT LED Ex USER INSTRUCTION OF LUMINAIRE
NORTHCLIFFE LIGHTING
2015-12-14 No. BARLEDEX-151214
Subject to change without notice
BARAT LED EX
Raudondvario pl. 101, Kaunas, Lithuania.
www.northcliffe.org
USER TO REPLACE BATTERIES
Accu-NiCd 4A 55
Nickel-cadmium cells (NiCd)
Batteries technical information:
Connection:
blade terminal
Number of cells:
4
Capacity
4.5Ah
1
2
3
4USE ONLY NiCd Batteries
5
6
Red –positive. Black –negative
WARNING –DO NOT CHANGE THE BATERRY WHEN THE EXPLOSIVE ATMOSPHERE IS POSSIBLE
This manual suits for next models
19
Table of contents
Other NORTHCLIFFE Lantern manuals